Barra de torsión aislante GIS 126-252kV

  • 126-252kV GIS Insulation torsion bar

Attributa principalia

Marca Switchgear parts
Numerus Modeli Barra de torsión aislante GIS 126-252kV
Votum nominatum 126-252kV
Series RN

Descriptiones productorum a fornitori

Descriptio

Barra torsionis insulatoria GIS 126-252kV est componentis transmissionis nucleare in apparatu commutatorio metallico clauso ad altam tensionem (GIS). Characteristicae technicae et puncta applicationis ingeniorum sunt sequentes:
1、 Functiones nucleares et requisitiones performance
Performance insulatoria electrica
Ad sustinendum voltus periodicum 126-252kV et impetus fulminis (sicut 550kV/950kV), intensitas electrica superficiale debet controlari sub 15kV/mm, et fortitudo dielectrica materialis debet esse ≥ 30kV/mm
Barra torsionis insulatoria GIS 252kV necessitat processum impregnationis pressura vacuae (resina epoxy+fibra polyester) ad assecurandum non adhesionem filata et ad implenda requisita apparatorum electricorum compositorum totaliter clausorum
Performance mechanica
Necessario sustinere onus impactus aperiendi et claudi (sicut interruptio currentis brevis-circuiti 40kA), cum frequencia responsus dynamicus 0-600Hz et vita mechanica ≥ 10000 vicibus
Materialis composite aramid/polyester potest augmentare levitatem et resistentiam fatigae, aptus pro tensionibus altis 252kV et super
2、 Innovatio in Materialibus et Processibus
Materialia mainstream
Tubus textilis vitreus epoxy: fabricatus per processum impregnationis vacuae, cum fortitudine mechanica alta, aptus pro unitate DS GIS 252kV
Fibra aramid: Processus formandi impregnationis pressura vacuae potest praeparare barras insulatorias cum structura interna densa, possidentes simul proprietates mechanicas et electricas
Optimizatio processus
Adoptando technologiam non adhaesionis filata ad evitandum concentrationem stressus causatum a structuris filatis et ad meliorandum fiduciam
Design tectoris pressurae (sicut operculum shielding+block positionis) potest effici pressuram una vice octo productorum, incrementans efficientiam per 200%
3、 Difficultates Technicae et Solutiones
Fatiga dynamicus
Impactus aperiendi et claudi facile potest causare rimos internos, quae necessitant verificationem per 100 testibus currentis brevis-circuiti plena capacitate
Adaptabilitas ambientalis
GIS amicalis ambienti sine fluoro 126kV (sicut apparatus insulator CO₂) requirit barras torsionis insulatorias ad sustinendum frigus (-40 ℃) et ad adaptandum characteribus novi media
4、 Applicationes Industriales et Standardes
Scenarii typici: GIS 252kV utitur pro projectis transmissionis ultra-altae tensionis, et GIS 126kV est aptus pro projectis generationis energiae novae
Basis specificationis: Conformatur standardibus GB/T 11022-2020 et IEC 60694

Cognosce tui fornitori
Venditio Online
Ratio praestabilitae tradendae
Tempus responsionis
100.0%
≤4h
Brevis Descriptio Societatis
Locus Operis: 1000m² Numerus omnium laborantium: Summa Annua Exportatio (USD): 300000000
Locus Operis: 1000m²
Numerus omnium laborantium:
Summa Annua Exportatio (USD): 300000000
Servitia
Genus Negotii: Venditio
Categorias Principales: pars componentium/Instrumenta inspectionis/apparatus electrum altum voltus/Apparatus electri bassa tensione/Instrumenta et mensurae/Instrumenta productiva/Ferramentae electricitatis
Gubernatio vitae
Servitia gestionis curae integralis pro quaestu, usu, conservatione et post-venditionem apparatus electricorum, securitatem operationis, continuationem imperii et usum electricitatis sine cura garantia.
Fornitori instrumentorum praeteritus est certificationem qualificationis platformae et iudicium technicum, ut ex fonte conformitas, professionalitas et fiducia servantur.

Producta Connexa

Cognitio Connexa

  • Accidentia Transformatoris Principalis et Questiones Operationis Gas Luminis
    1. Registri accidentis (XIX Martii, MMXIX)Hora XVI:XIIX die XIX Martii, MMXIX, monitorium background reportavit actionem gas levis transformatoris principis numeri III. Conformiter Codex Operationis Transformatorum Electricitatis (DL/T572-2010), personale operationis et maintenance (O&M) inspectavit statum in situ transformatoris principis numeri III.Confirmatio in situ: Panel non-electricus protectionis WBH transformatoris principis numeri III reportavit actionem gas levis phase B corpus tr
    02/05/2026
  • Culpae et Tractatio Terrae Unipolaris in Lineis Distributionis 10kV
    Characteristica et Instrumenta Detegendi Defectus Terrae Monofasiales1. Characteristica Defectuum Terrae MonofasialiumSigna Centralia Admonitionis:Campanula admonitionis sonat, et lucerna indicativa inscripta „Defectus Terrae in Sectione Omnibus [X] kV [Y]“ accenditur. In systematibus ubi punctum neutrum per bobinam Petersen (bobinam suppressionis arcus) ad terram connectitur, lucerna indicativa „Bobina Petersen Operatur“ etiam accenditur.Indicationes Voltmetri Monitoris Isolationis:Tensio phase
    01/30/2026
  • Modus operationis terre iunctae puncti neutralis pro transformatoribus retis electricitatis 110kV~220kV
    Dispositio modi operis terrae puncti neutralis pro transformatoribus rete electricitatis 110kV~220kV debet exigentias tolerationis insulationis puncti neutralis transformatorum complere, et simul conari ut impedimentum sequentiae nullae stationum transformationis fere immutatum maneat, dum certatur ne impedimentum sequentiae nullae compositum in quocumque puncto raptus circuiti systematis ultra ter impedimentum sequentiae positivae compositum excedat.Pro transformatoribus 220kV et 110kV in novis
    01/29/2026
  • Cur Quare Substationes Lapidem Gravem Calculos et Rupem Fractam Utuntur
    Cur Quare Substationes Utuntur Lapidibus, Gravibus, Piscinis et Saxis Tritis?In stationibus transformationis, instrumenta ut transformatores electricitatis et distributionis, lineae transmissionis, transformatores tensionis, transformatores currentis et commutatores disiunctionis omnia terram exigunt. Praeter terram, nunc profundius explorabimus cur gravia et saxa trita in stationibus transformationis saepe utuntur. Quamquam videantur ordinaria, isti lapides partem criticam iuxtaque functionalem
    01/29/2026
  • Cur autem nucleus transformatoris tantum in uno puncto terram tangere debet Nonne terra multipuncta fidelius est
    Cur ergo nucleus transformatoris terram tangere debet?In operatione, nucleus transformatoris, simul cum structuris, partibus et componentibus metallicis quae fixant nucleum et spiras, in forti campo electrico situs est. Sub influentia huius campi electrici, potentialem relativum altum ad terram comparatum acquirunt. Si nucleus non terra tangitur, differentia potentialis inter nucleum et structuras claudicantes et vas terratum existet, quae possit ad intermitterentiam dismissionem ducere.Praetere
    01/29/2026
  • Intellegere Terram Neutralis Transformatoris
    I. Quid est Punctum Neutrum?In transformatoribus et generatoribus, punctum neutrum est locus specificus in spira ubi absoluta tensio inter hunc locum et singula terminalia externa aequalis est. In diagrammate infra, punctumOrepraesentat punctum neutrum.II. Cur Punctum Neutrum Terrendum Est?Modus connexionis electricae inter punctum neutrum et terram in systemate AC triphasico diciturmodus terrendi puncti neutri. Hic modus directe afficit:Securitatem, fidem et oeconomiciam retelectrici;Selectione
    01/29/2026
Non invenisti adhuc opportunos fornitoris ut te inveniant Citationem Nunc Accipe
Non invenisti adhuc opportunos fornitoris ut te inveniant
Citationem Nunc Accipe
Inquiry
+86
Click to upload file
Descarica
Obtine Applicatio Commerciale IEE-Business
Utiliza app IEE-Business ad inveniendum apparatus obtinendumque solutiones coniungendum cum peritis et participandum in collaboratione industriale ubique et semper propter totam supportionem tuorum projectorum electricitatis et negotiorum