10kV SG(B) IEE-Business Amicus Ecologicus Non-Obductus Tranformator Secundum Typum Siccum

  • 10kV SG(B) Environmentally Friendly Non-encapsulated Dry-Type Transformer

Attributa principalia

Marca ROCKWILL
Numerus Modeli 10kV SG(B) IEE-Business Amicus Ecologicus Non-Obductus Tranformator Secundum Typum Siccum
Votum nominatum 10kV
Frequenta nominata 50/60Hz
Capacitas nominata 1000kVA
Series SG(B)

Descriptiones productorum a fornitori

Descriptio

Product overview

Series SG(B)10/11 non-encapsulated dry-type transformer est nova generatio viridis et amicae ambientis transformatoris sicci cum excellenti resistencia ad condicionem meteorologicam, sicut resistencia ad umiditatem, salinum nebula, securus et fidelis operatio ad altam temperaturam, parva emissio partialis, parvus sonus, alta efficacia dissipacionis caloris et fortis capacitas supercargar. Optime adaptatus ad hydroelectricas stationes, thermicas stationes, siderurgiam, industrias chimicas, minas in regionibus cum alta temperatura et alta polluctio.

 Characteristica producti

  • SG (B) 10/11 fundatur in systemate chartarum DuPont NOMEX et conservat excellentem performance electricam et mechanicam per totam vitam transformatoris. Charta NOMEX non senescit facile, resistentia ad contractionem et compressionem, plus vi elasticitatis, ita ut possit asseverare structuram transformatoris strictam et sustinere pressionem currentis circuiti brevis.

  • Insulatio H: insulatio transformatoris sicci est gradus H. Temperatura tolerabilis est 180℃. Productum usitat chartam NOMEX ut materiale principale insulationis, cuius gradus insulationis attingit H, et partes claves gradu C.

  • Securitas: producta SG (B) 10/11, omnia materialia insulationis non sunt combustibilia, extinguit se sponte, non toxica, et materiales combustibiles sunt minus quam 10% productorum infusorum epoxy. Fumus toxicus paene nullus generatur ab combustione longa tempore ad altam temperaturam 800℃, sic superando defectum magnae quantitatis gas toxicorum quando transformator siccus infusus epoxy ardet. Producta SG (B) 10/11 sunt superiora in occasionibus cum alta exigitate securitatis, sicut in metro, navi, industria chimica, fusione etc., ubi est humiditas et ventilatio mala.

  • Fidelitas: design specialis spire, processus et materialia pro productis SG (B) 10/11. Productum habet excellentem performance (resistens ad umiditatem, mufetas, salinum nebula), et potest sustinere shock calorificus. Non fractura nec parva emissio partialis.

  • Proteccio ambientalis: producta SG (B) 10/11 non polluunt ambientem dum fabricantur, transportantur, conservantur vel operantur. Post periodum vitae, productum potest decomponi et recuperari ad satisfaciendum necessitatibus clientium, superando defectum transformatoris sicci infusi epoxy, quia resina et filum vitrei solidificantur et non possunt decomponi post periodum vitae, polluentes ambientem. Producta typi SG10 sunt parvi soni et apta ad regiones habitacionales densas vel alios locos modernos.

  • Alta capacitas supercargar: productum SG (B) 10/11 usitat chartam DuPont NOMEX ut materiale principale insulationis et ut systema hybridum insulationis in loco maxime calefacto transformatoris, reducens volumen et pondus per 30% comparato cum transformatore infuso epoxy eiusdem capacitatis.

Modello producti

  • S: Triphasus

  • G: Insulatio aeria

  • (B): Spira laminae bassae tensionis

  • Prima □: Codex performance producti (10.11)

  • Secunda □: Capacitas nominata (kVA)

  • Tertia □: Gradus tensionis (kV)

Parametri performance - Parametri technici transformatoris sicci non-encapsulati SG(B)10 classis 10kV

Rated Capacity

Voltage Combination and Tap Range

Connection Group

No-load Loss (W)

Load Loss W at Different Insulation Thermal Levels

No-load Current %

Short-circuit Impedance %

High Voltage KV

Tap Range %

Low Voltage KV

F (120°C)

H (145°C)

30

6

6.3

6.6

10

10.5

11

±5±2×2.5


0.4

Yyno

Dyn11

180

740

790

2.3

4.0

 

50

250

1060

1140

2.2

80

330

1470

1570

1.7

100

360

1690

1830

1.7

125

420

1980

2120

1.5

160

490

2320

2480

1.5

200

580

2690

2880

1.3

250

660

3070

3300

1.3

315

780

3690

3970

1.1

400

890

4350

4640

1.1

500

1040

5160

5530

0.9

630

1200

6140

6560

0.9

630

1160

6330

6800

0.9

6.0

800

1370

7380

7900

0.9

1000

1560

8730

9420

0.9

1250

1810

10390

11140

0.9

1600

2400

12770

13650

0.9

2000

2700

15300

16540

0.7

2500

3150

18420

19720

0.7

1600

2400

13720

14690

0.9

8.0

2000

2700

16720

18060

0.7

2500

3150

19840

21330

0.7

Nota: parametri supra sunt tantum pro valoribus typicis et possunt ad voluntatem clientis adaptari.

Criterium implementationis: GB1094.11-2007, GB/T10228-2008, IEC60076-11

Parametri Praestantiae - Parametri Technici Transformatoris Siccitatis Non-Obliterati SG(B)11 Classis 10kV

Rated Capacity

Voltage Combination and Tap Range

Connection Group

No-load Loss (W)

Load Loss (W)

No-load Current (A)

Total Weight (kg)

Outline Dimensions 

(Length * Width *  Height mm)

Track Gauge (mm)

Short-circuit Impedance %

High Voltage KV

Tap Range %

Low Voltage KV

Lateral

Longitudinal

100

6

6.3

6.6

10

10.5

11

±5±2×2.5


0.4

Yyno

Dyn11

320

1690

0.6

610

820 * 680 * 890

550 * 550

4.0

160

440

2280

0.6

860

1010 * 900 * 990

200

520

2710

0.5

1000

1040 * 900 * 1050

660 * 660

250

590

2960

0.5

1150

1060 * 900 * 1180

315

700

3730

0.5

1350

1120 * 1000 * 1180

400

800

4280

0.4

1600

1150 * 1000 * 1280

500

930

5230

0.4

2030

1160 * 1000 * 1280

630

1040

5400

0.3

2400

1340 * 1000 * 1280

820 * 820

6.0

800

1230

7460

0.3

2500

1390 * 1000 * 1290

1000

1400

8760

0.3

2980

1450 * 1100 * 1350

1250

1620

10370

0.25

3500

1480 * 1100 * 1450

1600

2160

12580

0.25

4180

1510 * 1100 * 1590

2000

2430

15560

0.2

5130

1780 * 1300 * 1600

1070 * 820

2500

2830

18450

0.2

6150

1830 * 1300 * 1900

Nota: parametri supra sunt tantummodo pro valori typici, et possunt ad custum clientis accommodari.

Criteria implementationis: GB1094.11-2007, GB/T10228-2008, IEC60076-11

Conditiones usus

  • Elevatio minor vel aequalis est 1000m,

  • Temperatura ambientalis: -25℃ ~ +40℃, transformatoris interioris, aeris refrigerationis et ventilationis forzatae.

  • Gradus protectionis est IP00, IP20, IP23, etc.

  • Requiritates specificae possunt secundum contractum designari.

 

Cognosce tui fornitori
Venditio Online
Ratio praestabilitae tradendae
Tempus responsionis
100.0%
≤4h
Brevis Descriptio Societatis
Locus Operis: 108000m²m² Numerus omnium laborantium: 700+ Summa Annua Exportatio (USD): 150000000
Locus Operis: 108000m²m²
Numerus omnium laborantium: 700+
Summa Annua Exportatio (USD): 150000000
Servitia
Genus Negotii: Design/Fabricatio/Venditio
Categorias Principales: apparatus electrum altum voltus/transformator
Gubernatio vitae
Servitia gestionis curae integralis pro quaestu, usu, conservatione et post-venditionem apparatus electricorum, securitatem operationis, continuationem imperii et usum electricitatis sine cura garantia.
Fornitori instrumentorum praeteritus est certificationem qualificationis platformae et iudicium technicum, ut ex fonte conformitas, professionalitas et fiducia servantur.

Producta Connexa

Cognitio Connexa

  • Accidentia Transformatoris Principalis et Questiones Operationis Gas Luminis
    1. Registri accidentis (XIX Martii, MMXIX)Hora XVI:XIIX die XIX Martii, MMXIX, monitorium background reportavit actionem gas levis transformatoris principis numeri III. Conformiter Codex Operationis Transformatorum Electricitatis (DL/T572-2010), personale operationis et maintenance (O&M) inspectavit statum in situ transformatoris principis numeri III.Confirmatio in situ: Panel non-electricus protectionis WBH transformatoris principis numeri III reportavit actionem gas levis phase B corpus tr
    02/05/2026
  • Culpae et Tractatio Terrae Unipolaris in Lineis Distributionis 10kV
    Characteristica et Instrumenta Detegendi Defectus Terrae Monofasiales1. Characteristica Defectuum Terrae MonofasialiumSigna Centralia Admonitionis:Campanula admonitionis sonat, et lucerna indicativa inscripta „Defectus Terrae in Sectione Omnibus [X] kV [Y]“ accenditur. In systematibus ubi punctum neutrum per bobinam Petersen (bobinam suppressionis arcus) ad terram connectitur, lucerna indicativa „Bobina Petersen Operatur“ etiam accenditur.Indicationes Voltmetri Monitoris Isolationis:Tensio phase
    01/30/2026
  • Modus operationis terre iunctae puncti neutralis pro transformatoribus retis electricitatis 110kV~220kV
    Dispositio modi operis terrae puncti neutralis pro transformatoribus rete electricitatis 110kV~220kV debet exigentias tolerationis insulationis puncti neutralis transformatorum complere, et simul conari ut impedimentum sequentiae nullae stationum transformationis fere immutatum maneat, dum certatur ne impedimentum sequentiae nullae compositum in quocumque puncto raptus circuiti systematis ultra ter impedimentum sequentiae positivae compositum excedat.Pro transformatoribus 220kV et 110kV in novis
    01/29/2026
  • Cur Quare Substationes Lapidem Gravem Calculos et Rupem Fractam Utuntur
    Cur Quare Substationes Utuntur Lapidibus, Gravibus, Piscinis et Saxis Tritis?In stationibus transformationis, instrumenta ut transformatores electricitatis et distributionis, lineae transmissionis, transformatores tensionis, transformatores currentis et commutatores disiunctionis omnia terram exigunt. Praeter terram, nunc profundius explorabimus cur gravia et saxa trita in stationibus transformationis saepe utuntur. Quamquam videantur ordinaria, isti lapides partem criticam iuxtaque functionalem
    01/29/2026
  • Cur autem nucleus transformatoris tantum in uno puncto terram tangere debet Nonne terra multipuncta fidelius est
    Cur ergo nucleus transformatoris terram tangere debet?In operatione, nucleus transformatoris, simul cum structuris, partibus et componentibus metallicis quae fixant nucleum et spiras, in forti campo electrico situs est. Sub influentia huius campi electrici, potentialem relativum altum ad terram comparatum acquirunt. Si nucleus non terra tangitur, differentia potentialis inter nucleum et structuras claudicantes et vas terratum existet, quae possit ad intermitterentiam dismissionem ducere.Praetere
    01/29/2026
  • Intellegere Terram Neutralis Transformatoris
    I. Quid est Punctum Neutrum?In transformatoribus et generatoribus, punctum neutrum est locus specificus in spira ubi absoluta tensio inter hunc locum et singula terminalia externa aequalis est. In diagrammate infra, punctumOrepraesentat punctum neutrum.II. Cur Punctum Neutrum Terrendum Est?Modus connexionis electricae inter punctum neutrum et terram in systemate AC triphasico diciturmodus terrendi puncti neutri. Hic modus directe afficit:Securitatem, fidem et oeconomiciam retelectrici;Selectione
    01/29/2026

Solutiones Relatae

  • Solutio Transformatoris Siccitatis: Systema Specialis pro Industriis Exigentibus (Systema Siccitatis Anti-Corrosionis / Altae Oneris)
    Solutio pro Transformatoribus Siccis: Systema Specialis pro Industriis Duris (Systema Anti-Corrosivum / Alta Overload)​​1. Difficultates Solvendae​​Industriae:​​ Chimica, Metallurgia, Navigium Faciendi, Energiae Installationes Littorales, etc.​Minacula Ambientalia:​​​Humiditas Extrema:​​ Humiditas relativa ambientalis constans vel longa tempore > 90%.​Corrosio:​​ Praesentia mediorum altius corrosivorum, sicut spray salinus, gase acidarum/alkalinarum (pH inter 2-12), vapores chemici.​Tensio Opera
    07/04/2025
  • Gemina Digitalis Dirigens Fabricam Sapientem: Solutio Intellectuale Proxima Generis pro Transformatoribus Siccis
    Gemina Digitalis Impulsata Fabrica Sapientialis: Solutio Intellectiva Proxima Generis pro Transformatoribus Siccis​In unda gemina transitionis energiae et fabricae sapientialis, Transformatores Siccis rapiditer evolvuntur ad digitalitatem et intelligentiam. Proposita nostra "Ecosistema Gemina Digitalis Transformatorum Siccis" integra technologias novissimas ut constituat systema managementis clausi circuitus intellectivum, quod totam vitam equipmenti operit, propellens industriam in novam aetate
    07/04/2025
  • Solutio technica: Series RW Immersio sub vacuum (VPI) transformatorum siccorum
    Solutio Technica: Series RW Transformatores Dry-Type Vacuum Pressure Impregnation (VPI)​​I. Innovationes Technologicae Principales​​Systema Insulationis Sine Defectibus​Utilizat processum Vacuum Pressure Impregnation (VPI) ad fundendi resina epoxy alta densitate, ad solidificandum insulationem sine vacuis.Niveles discharges partialium stabiliter controlati ad ​<10 pC​ (standard IEC 60076-11).Classis thermalis insulationis attingit ​Classis H (180°C)​, cum degradatio performance insulation
    07/04/2025
Instrumenta Libera Cognata
Non invenisti adhuc opportunos fornitoris ut te inveniant Citationem Nunc Accipe
Non invenisti adhuc opportunos fornitoris ut te inveniant
Citationem Nunc Accipe
Inquiry
+86
Click to upload file
Descarica
Obtine Applicatio Commerciale IEE-Business
Utiliza app IEE-Business ad inveniendum apparatus obtinendumque solutiones coniungendum cum peritis et participandum in collaboratione industriale ubique et semper propter totam supportionem tuorum projectorum electricitatis et negotiorum