substantia electrica compacta combinata exterior pro substationibus transmissionis 10kV 12kV 35kV IEE-Business

  • 10kV 12kV 35kV transmission substation outdoor combined electrical compact substation
  • 10kV 12kV 35kV transmission substation outdoor combined electrical compact substation

Attributa principalia

Marca Vziman
Numerus Modeli substantia electrica compacta combinata exterior pro substationibus transmissionis 10kV 12kV 35kV IEE-Business
Votum nominatum 10kV
Frequenta nominata 50/60Hz
Series ZGS

Descriptiones productorum a fornitori

Descriptio

Product Overview

Compacta Substationis Secundaria (CSS) est facilis integrata externa potentia, quae includit commutatores mediae tensionis (MV), transformatores distributionis, tabulas parvae tensionis (LV), et auxiliaria in unica protegente clausura. Facilitat conversionem potestatis ab ingressu MV 10-35kV ad egressum LV 0.4kV. Cum designo modulare et componentibus certificatis arc-test, clausura eius respondet standardibus protectionis IP54+, permitens installationem directam in locis publicis sicut communitates et parci commerciales.
Pro insulamento forti et capacitate sustinendi circuitus breves testata, CSS incorporat systema protectionis arcuum et modulos intelligentes monitoring pro surveillance conditionis remota. Complectitur totum processum conversionis potestatis ab ingressu altae tensionis ad distributionem parvae tensionis in spatio compacto, praebens solutiones potestatis finales securas et fideles pro reticulis distributionis urbanis.
Feature
  • Alta Integratio:Combinat commutatores MV, transformator, et panel LV in una clausura, reducens spatium pedalis per 40%-60%. Convertit directe 10-35kV ad 0.4kV in uno unitate compacta.
  • Expansibilitas Modulare:Designo standardizatum cum compartimentis MV/transformator/LV. Capacitas adjustabilis ab 500-2000kVA. Upgrades faciles per replacementem modulorum.
  • Robusta Protectio Securitatis:Clausura IP54+, componentes arc-test, tensio AC sustinenda 42kV 1 minuto, tolerantia circuiti brevis 31.5kA.
  • Monitoring Intelligentis:Monitoring real-time temperaturae olei/onerae. Interfaces RS485/Ethernet pro alerta de vitiis remota.
  • Secura & Ecologica:Reductio soni ≤55dB, clausura amica ad landscape, designo anti-shock conformi IEC 62271-200.
  • Energeticamente Efficiens & Fidelis:Nucleus ferri silicis parva-perditio reducit perditias sine onere per 30%. MTBF excedit 100,000 horas.
  • Installatio Rapida:Praefabricata pro 50% setup on-site brevior. Deployment flexibilis in collibus, spatia angusta.
Parametri Technici
 
Cognosce tui fornitori
Venditio Online
Ratio praestabilitae tradendae
Tempus responsionis
100.0%
≤4h
Brevis Descriptio Societatis
Locus Operis: 10000m² Numerus omnium laborantium: 300 Summa Annua Exportatio (USD): 150000000
Locus Operis: 10000m²
Numerus omnium laborantium: 300
Summa Annua Exportatio (USD): 150000000
Servitia
Genus Negotii: Design/Fabricatio/Venditio
Categorias Principales: apparatus electrum altum voltus/transformator
Gubernatio vitae
Servitia gestionis curae integralis pro quaestu, usu, conservatione et post-venditionem apparatus electricorum, securitatem operationis, continuationem imperii et usum electricitatis sine cura garantia.
Fornitori instrumentorum praeteritus est certificationem qualificationis platformae et iudicium technicum, ut ex fonte conformitas, professionalitas et fiducia servantur.

Producta Connexa

Cognitio Connexa

  • Accidentia Transformatoris Principalis et Questiones Operationis Gas Luminis
    1. Registri accidentis (XIX Martii, MMXIX)Hora XVI:XIIX die XIX Martii, MMXIX, monitorium background reportavit actionem gas levis transformatoris principis numeri III. Conformiter Codex Operationis Transformatorum Electricitatis (DL/T572-2010), personale operationis et maintenance (O&M) inspectavit statum in situ transformatoris principis numeri III.Confirmatio in situ: Panel non-electricus protectionis WBH transformatoris principis numeri III reportavit actionem gas levis phase B corpus tr
    02/05/2026
  • Culpae et Tractatio Terrae Unipolaris in Lineis Distributionis 10kV
    Characteristica et Instrumenta Detegendi Defectus Terrae Monofasiales1. Characteristica Defectuum Terrae MonofasialiumSigna Centralia Admonitionis:Campanula admonitionis sonat, et lucerna indicativa inscripta „Defectus Terrae in Sectione Omnibus [X] kV [Y]“ accenditur. In systematibus ubi punctum neutrum per bobinam Petersen (bobinam suppressionis arcus) ad terram connectitur, lucerna indicativa „Bobina Petersen Operatur“ etiam accenditur.Indicationes Voltmetri Monitoris Isolationis:Tensio phase
    01/30/2026
  • Modus operationis terre iunctae puncti neutralis pro transformatoribus retis electricitatis 110kV~220kV
    Dispositio modi operis terrae puncti neutralis pro transformatoribus rete electricitatis 110kV~220kV debet exigentias tolerationis insulationis puncti neutralis transformatorum complere, et simul conari ut impedimentum sequentiae nullae stationum transformationis fere immutatum maneat, dum certatur ne impedimentum sequentiae nullae compositum in quocumque puncto raptus circuiti systematis ultra ter impedimentum sequentiae positivae compositum excedat.Pro transformatoribus 220kV et 110kV in novis
    01/29/2026
  • Cur Quare Substationes Lapidem Gravem Calculos et Rupem Fractam Utuntur
    Cur Quare Substationes Utuntur Lapidibus, Gravibus, Piscinis et Saxis Tritis?In stationibus transformationis, instrumenta ut transformatores electricitatis et distributionis, lineae transmissionis, transformatores tensionis, transformatores currentis et commutatores disiunctionis omnia terram exigunt. Praeter terram, nunc profundius explorabimus cur gravia et saxa trita in stationibus transformationis saepe utuntur. Quamquam videantur ordinaria, isti lapides partem criticam iuxtaque functionalem
    01/29/2026
  • Cur autem nucleus transformatoris tantum in uno puncto terram tangere debet Nonne terra multipuncta fidelius est
    Cur ergo nucleus transformatoris terram tangere debet?In operatione, nucleus transformatoris, simul cum structuris, partibus et componentibus metallicis quae fixant nucleum et spiras, in forti campo electrico situs est. Sub influentia huius campi electrici, potentialem relativum altum ad terram comparatum acquirunt. Si nucleus non terra tangitur, differentia potentialis inter nucleum et structuras claudicantes et vas terratum existet, quae possit ad intermitterentiam dismissionem ducere.Praetere
    01/29/2026
  • Intellegere Terram Neutralis Transformatoris
    I. Quid est Punctum Neutrum?In transformatoribus et generatoribus, punctum neutrum est locus specificus in spira ubi absoluta tensio inter hunc locum et singula terminalia externa aequalis est. In diagrammate infra, punctumOrepraesentat punctum neutrum.II. Cur Punctum Neutrum Terrendum Est?Modus connexionis electricae inter punctum neutrum et terram in systemate AC triphasico diciturmodus terrendi puncti neutri. Hic modus directe afficit:Securitatem, fidem et oeconomiciam retelectrici;Selectione
    01/29/2026

Solutiones Relatae

Non invenisti adhuc opportunos fornitoris ut te inveniant Citationem Nunc Accipe
Non invenisti adhuc opportunos fornitoris ut te inveniant
Citationem Nunc Accipe
Inquiry
+86
Click to upload file
Descarica
Obtine Applicatio Commerciale IEE-Business
Utiliza app IEE-Business ad inveniendum apparatus obtinendumque solutiones coniungendum cum peritis et participandum in collaboratione industriale ubique et semper propter totam supportionem tuorum projectorum electricitatis et negotiorum