10kV (Tres Circuits) Commutator Aeris Insulatus Sub Normali Pressione / Unitas Principalis Annularis

  • 10kV (Three Circuits) Normal Pressure Sealed Air-Insulated Switchgear / Ring Main Unit

Attributa principalia

Marca ROCKWILL
Numerus Modeli 10kV (Tres Circuits) Commutator Aeris Insulatus Sub Normali Pressione / Unitas Principalis Annularis
Votum nominatum 12kV
Frequenta nominata 50/60Hz
Series XGN

Descriptiones productorum a fornitori

Descriptio

Descriptio

Apparatus commutatorium aeris insulatum normale pressionis pro distributione electricitatis mediae tensionis ad 10kV (tres circuitus) est solutio ingeniosa pro supportandis tribus circuitibus electricitatis independenter. Operatur ad tensione nominata 10kV, et habet clausuram hermeticam normale pressionis quae utitur aere ut medio principaliter insulantem—eliminans necessitatem gas SF₆ vel systemata pressurizata. Hoc apparatum integrat functiones commutationis, protectionis, et controlis, idoneum faciens ad casus qui requirunt robustam distributionem multi-circuitalem, sicut in complexibus industrialibus, substationibus urbanis, centris commercialibus, et infrastructura critica quae requirit supplymentum electricitatis redundans.

Characteristica Principalia

  • Configuratio Tri-Circuitalis: Supportat tres circuitus separatos, permitens distributionem flexibilem electricitatis, commutationem sine intermissione oneris, et redundancy augmentatam. Hoc designo minuit tempus intermissionis certificando continuitatem etiam si unus circuitus requirit maintenance vel experit defectum.

  • Pressio Normalis & Insulatio Aeris: Operatur ad pressione atmospherica cum aere ut medio insulantem, eliminans pericula effluvii gas, pollutionis environmentalis, aut refilling gas. Hoc reducit costus maintenance longi temporis et conformatur standardibus eco-friendly.

  • Clausura Hermetica: Structura hermeticam protectiva internas partes ab umiditate, pulvere, substantiis corrosivis, et debri externis, certificans stabilitatem performance in ambientibus asperis vel variabilibus (sicut in humiditate alta, zonas industriales).

  • Compacta & Spatii Efficiens: Designo modularis optimizatus cum vestigio minus comparato ad switchgears multi-circuitales traditionales, idoneum faciens ad installationes cum spatiis limitatis, sicut in substationibus urbanis aut camera distributionis interioribus.

  • Alta Securitas & Fiducia: Equipata cum interlock mechanico, mechanismis anti-misoperation, et punctis isolationis visibilibus praeventis contactu accidentali cum partibus vivis. Designo clausus mitigat pericula arc flash, augmentans securitatem operatoris.

  • Maintenance Minima: Componentes mechanicis simplificatis cum vita longa (usque ad 10,000 operationes) et nulla necessitate monitoring gas aut refilling, reducens interruptiones operationis et costus lifecycle.

  • Integration Scalabilis: Compatibilis cum systematis grid smart, supportans monitoring remote et control. Structura modulare permittit installationem facilis in situ et expansionem futuram, adaptans ad evolutionem necessitatium distributionis electricitatis.

Nomen

Unitas

Valorem Parametri

Tensio Nominata (Ur)

kV

12

Frequensia Nominata (fr)

Hz

50

Currentus Nominatus (Ir)

A

630

Resistentia Temporalis Brevis Frequentiae Potentiae (Ud)

Inter Fracturas

kV

48

Inter Phases

kV

42

Phase ad Terram

kV

42

Resistentia Impulsus Fulminantis (Up)

Inter Fracturas

kV

95

Inter Phases

kV

75

Phase ad Terram

kV

75

Currentus Nominatus Resistentiae Temporalis Brevis (Ik)

kA

20/25

Duratio Circuitus Brevis Nominata (tk)

s

4

Currentus Nominatus Resistentiae Cuspis (Ip)

kA

50/63

Currentus Nominatus Interrumpendi Circuitus Brevis (Isc)

kA

20/25

Currentus Nominatus Faciendi Circuitus Brevis (Ima)

 

Interruptor Vacuum

kA

50/63

Commutor Terra



Circuitus Auxiliaris et Controlis

Tensio Nominata (Ua) DC/AC

V

≤400

Resistentia Frequentiae Potentiae (1min)

V

2000

Vita Mechanica

 

Interruptor Circuitus

Tempora

10000

Commutor Disconnectionis

Tempora

3000

Commutor Terra

Tempora

3000

Vita Electrica  

Interruptor Circuitus

Classis

E2

Commutor Terra

Classis

E2

Gradus Protectionis Clausurae Armarii


IP4X

Gradus Protectionis Clausurae Box


IP65

FAQ
Q: Quod est gradus protectionis IP armarii generaliter ambiens conservantis?
A:
Nivellus protectionis IP standardus armariorum generalium ambiensialiter conservantium est IP54, qui prohibere potest accumulationem pulveris et aspersionem aquae ab omnibus directionibus. In ambientes duros (exempli gratia, regiones litorales cum spuma salis, loca constructoria pulvere plena), armaria altius protectionis cum IP65 vel superiore sunt disponibilia, quae prohibere possunt ingressum pulveris totaliter et resistere lavationi jetto aquae sub pressione parva.
Q: Quomodo se habet capacitas rumpendi circuitum brevem armarii ambientaliter benigni
A:
Capacitas rumpendi circuitus apertorum armariolorum mediocri tensurae (12kV) amicae naturae solito est 25kA-31.5kA, quae satisfacit exigentiae plerisque systematis distributionis mediocri tensurae. Saepe adhibentur interpellatores vacui pro extinguendo arcu, qui praebent excellentem capacitatem rumpendi circuitus apertos et celeriter possunt secare currentes defectorum ut protegant rete electricum et apparatum. Capacitas rumpendi probatur per testes typi secundum normas IEC 62271-203.
Cognosce tui fornitori
Venditio Online
Ratio praestabilitae tradendae
Tempus responsionis
100.0%
≤4h
Brevis Descriptio Societatis
Locus Operis: 108000m²m² Numerus omnium laborantium: 700+ Summa Annua Exportatio (USD): 150000000
Locus Operis: 108000m²m²
Numerus omnium laborantium: 700+
Summa Annua Exportatio (USD): 150000000
Servitia
Genus Negotii: Design/Fabricatio/Venditio
Categorias Principales: apparatus electrum altum voltus/transformator
Gubernatio vitae
Servitia gestionis curae integralis pro quaestu, usu, conservatione et post-venditionem apparatus electricorum, securitatem operationis, continuationem imperii et usum electricitatis sine cura garantia.
Fornitori instrumentorum praeteritus est certificationem qualificationis platformae et iudicium technicum, ut ex fonte conformitas, professionalitas et fiducia servantur.

Producta Connexa

Cognitio Connexa

  • Accidentia Transformatoris Principalis et Questiones Operationis Gas Luminis
    1. Registri accidentis (XIX Martii, MMXIX)Hora XVI:XIIX die XIX Martii, MMXIX, monitorium background reportavit actionem gas levis transformatoris principis numeri III. Conformiter Codex Operationis Transformatorum Electricitatis (DL/T572-2010), personale operationis et maintenance (O&M) inspectavit statum in situ transformatoris principis numeri III.Confirmatio in situ: Panel non-electricus protectionis WBH transformatoris principis numeri III reportavit actionem gas levis phase B corpus tr
    02/05/2026
  • Culpae et Tractatio Terrae Unipolaris in Lineis Distributionis 10kV
    Characteristica et Instrumenta Detegendi Defectus Terrae Monofasiales1. Characteristica Defectuum Terrae MonofasialiumSigna Centralia Admonitionis:Campanula admonitionis sonat, et lucerna indicativa inscripta „Defectus Terrae in Sectione Omnibus [X] kV [Y]“ accenditur. In systematibus ubi punctum neutrum per bobinam Petersen (bobinam suppressionis arcus) ad terram connectitur, lucerna indicativa „Bobina Petersen Operatur“ etiam accenditur.Indicationes Voltmetri Monitoris Isolationis:Tensio phase
    01/30/2026
  • Modus operationis terre iunctae puncti neutralis pro transformatoribus retis electricitatis 110kV~220kV
    Dispositio modi operis terrae puncti neutralis pro transformatoribus rete electricitatis 110kV~220kV debet exigentias tolerationis insulationis puncti neutralis transformatorum complere, et simul conari ut impedimentum sequentiae nullae stationum transformationis fere immutatum maneat, dum certatur ne impedimentum sequentiae nullae compositum in quocumque puncto raptus circuiti systematis ultra ter impedimentum sequentiae positivae compositum excedat.Pro transformatoribus 220kV et 110kV in novis
    01/29/2026
  • Cur Quare Substationes Lapidem Gravem Calculos et Rupem Fractam Utuntur
    Cur Quare Substationes Utuntur Lapidibus, Gravibus, Piscinis et Saxis Tritis?In stationibus transformationis, instrumenta ut transformatores electricitatis et distributionis, lineae transmissionis, transformatores tensionis, transformatores currentis et commutatores disiunctionis omnia terram exigunt. Praeter terram, nunc profundius explorabimus cur gravia et saxa trita in stationibus transformationis saepe utuntur. Quamquam videantur ordinaria, isti lapides partem criticam iuxtaque functionalem
    01/29/2026
  • Cur autem nucleus transformatoris tantum in uno puncto terram tangere debet Nonne terra multipuncta fidelius est
    Cur ergo nucleus transformatoris terram tangere debet?In operatione, nucleus transformatoris, simul cum structuris, partibus et componentibus metallicis quae fixant nucleum et spiras, in forti campo electrico situs est. Sub influentia huius campi electrici, potentialem relativum altum ad terram comparatum acquirunt. Si nucleus non terra tangitur, differentia potentialis inter nucleum et structuras claudicantes et vas terratum existet, quae possit ad intermitterentiam dismissionem ducere.Praetere
    01/29/2026
  • Intellegere Terram Neutralis Transformatoris
    I. Quid est Punctum Neutrum?In transformatoribus et generatoribus, punctum neutrum est locus specificus in spira ubi absoluta tensio inter hunc locum et singula terminalia externa aequalis est. In diagrammate infra, punctumOrepraesentat punctum neutrum.II. Cur Punctum Neutrum Terrendum Est?Modus connexionis electricae inter punctum neutrum et terram in systemate AC triphasico diciturmodus terrendi puncti neutri. Hic modus directe afficit:Securitatem, fidem et oeconomiciam retelectrici;Selectione
    01/29/2026

Solutiones Relatae

  • Design Solution of 24kV Siccum Aera Insulatum Ring Main Unit
    Combinatio Solidi Insulationis Adiuvantis + Insulationis Aereae Siccae repraesentat directionem pro RMU 24kV. Per requirementa insulationis cum compactitate equilibrata et adiuvante solidum insulationis, testes insulationis sine magnificatione significativa dimensionum inter phasos et inter phasos et terram transigi possunt. Inclusio columnae pole solidificat insulationem pro interruptore vacuo et conductoribus eius coniunctis.Maintinendo spatium phasorum exiens 24kV ad 110mm, intensitas electri
    08/16/2025
  • Optimizatio Design Schematum pro Unitate Circulorum Principalium Aere Insulata 12kV ad Minuendam Probabilitatem Disruptionis Emissionis
    Cum celeri progressus industriae electricitatis, conceptus ecologicus de carbonis minore, energiae servanda, et conservatione ambientis profundissime integratus est in designum et fabricam productorum electricorum pro distributione et generatione electricitatis. Unitas Distributiva Circuli (RMU) est dispositivum electricum clavem in retibus distributionis. Securitas, conservatio ambientis, fides operativa, efficacia energetica, et oeconomia sunt tendentiae inevitabiles in eius progressu. RMUs tr
    08/16/2025
  • Analyse communium problematum in unitatibus principali circuitu isolatis gas 10kV (RMUs)
    Introductio:​​RMUs insulati gaseis 10kV sunt amplissime usitati propter multas suas utilitates, sicut quod sint perfecte clausi, habeant excellentem insulativam qualitatem, non requirant maintenance, sint compacti, et praebent installationem flexibilem et commodam. In hoc stadio, paulatim facti sunt nodus criticus in rete distributionis urbano anulari et iocabuntur partem significativam in systemate distributionis electricitatis. Difficultates in RMUs insulatis gaseis possunt graviter impingere
    08/16/2025
Non invenisti adhuc opportunos fornitoris ut te inveniant Citationem Nunc Accipe
Non invenisti adhuc opportunos fornitoris ut te inveniant
Citationem Nunc Accipe
Inquiry
+86
Click to upload file
Descarica
Obtine Applicatio Commerciale IEE-Business
Utiliza app IEE-Business ad inveniendum apparatus obtinendumque solutiones coniungendum cum peritis et participandum in collaboratione industriale ubique et semper propter totam supportionem tuorum projectorum electricitatis et negotiorum