Series Fulminis Absorbentes cum Oxido Metalli in Aedificio Ceramico ad 1000kV

  • 1000kV Series Porcelain-Housed Metal Oxide Surge Arresters

Attributa principalia

Marca ROCKWILL
Numerus Modeli Series Fulminis Absorbentes cum Oxido Metalli in Aedificio Ceramico ad 1000kV
Votum nominatum 828kV
Frequenta nominata 50/60Hz
Series Y20W

Descriptiones productorum a fornitori

Descriptio

Descriptio 1000kV Series Porcellana - Housed Metal Oxide Surge Arresters

Arrestores de sursum in serie 1000kV porcellana - housed metal oxide sunt dispositiva protectiva cruciale pro systemibus transmissionalibus et transformationalibus ultra-altae tensionis (UHV, 1000kV). Installantur in substationibus 1000kV, lineis transmissionis, et apparatibus clavibus associatis (sicut transformatoribus et interruptoribus circuiti). Hi arrestores designati sunt ad suppressam super-tensiones causatas ab fulminibus, operationibus commutationis, et defectibus systematis. Inclusi in habitaculis porcellanearum altae fortitudinis, utilitant technologiam varistorum metallo-oxidicorum (MOV) praestantissimam. Divertendo cursus sursum excesseos ad terram et manutinendo niveles tensionis stabilis in operatione normali, salvaguardant integritatem et fiduciam reti UHV 1000kV, prohibentes damnum apparatum et intermissiones magnas potentiae.

Characteristica 1000kV Series Porcellana - Housed Metal Oxide Surge Arresters

  • Adaptabilitas Tensionis UHV:Specificiter ingeniosi pro systemibus potentiae UHV 1000kV, cum tensione nominata precise congruente cum requisitis rete 1000kV. Potest efficaciter limitare super-tensiones intra fines securitatis etiam sub conditionibus sursum extremis, assecurans operationem stabilem reti transmissionis UHV magnae scalae.

  • Habitaculum Porcellaneum Robustum:Habitaculum porcellaneum praebet excellentem fortitudinem mechanicam et resistentiam ambientalem. Potest sustinere factores ambientales duros sicut humiditatem altam, pollutionem industrialis, variationes latas temperaturarum (a -40°C ad 60°C), et activitatem seismicam fortis. Hoc habitaculum praebet isolationem electricam fidelis et protectionem physica componentibus internis, assecurans operationem stabilis longaevam.

  • MOVs Praestantissimi:Equipati cum varistoribus metallo-oxidicis (MOVs) state-of-the-art. Hi MOVs exhibent excellentes characteres resistentiae non-lineares. Durante eventus super-tensionis, cito conducunt cursus sursum, et sub conditionibus operationis normalis, revertunt ad statum altae resistentiae, minuentes cursus effluens (solito minus quam 100μA). Hoc cursus effluens parvus minuit perdas potentiae in systema et augit efficientiam totalem arrestoris.

  • Capacitas Exceptionalis Sustinentis Sursum:Potens tractare impulsus currents enormes (usque ad plures centenas kA) generatos ab fulminibus aut sursum commutationis. Haec alta tolerancia sursum efficaciter protegit apparatu adjacentia (sicut transformatoribus et interruptoribus circuiti) a spiculis tensionis, prohibens damnum apparatum et assecurans continuitatem suppeditationis potentiae.

  • Compatibilitas Configurationis Seriei:Designati pro connectione seriei ad satisfaciendum requisitis tensionis 1000kV. Integrati cum dispositivis graduentibus tensionem (sicut capacitors graduentibus aut annuli), assecurant distributionem uniformem tensionis inter plures unitates arrestoris in serie. Haec distributio uniformis augit stabilitatem et fiduciam totius systematis protectionis potentiae UHV 1000kV.

  • Requisitus Minimus Maintenance:Habitaculum porcellaneum habet bonam resistentiam ad corrosionem et proprietates self-cleaning in plerisque ambientibus naturalibus, reducens frequentiam maintenance. Praeterea, multi exemplaria equipata sunt cum portis monitoring pro detectione cursus effluens et temperature. Hi portae permittunt maintenance predictivam, permitting operators detectare potentialia defectus in advance et agere preventiva, reducens intermissiones non-planificatas.

  • Compliance cum Standardibus Internationalibus:Adhaeret strictis standardibus industriales internationalibus sicut IEC 60099-4 et ANSI/IEEE C62.11. Haec compliance assecurat compatibilitatem cum systemibus potentiae 1000kV universali et garantit quod adhibeat summum benchmarks security et performance in industria potentiae.

parameters

Model 

Arrester

System

Arrester Continuous Operation

DC 1mA

Switching Impulse

Nominal Impulse

Steep-Front Impulse

2ms Square Wave

Nominal

Rated Voltage

Nominal Voltage

Operating Voltage

Reference Voltage

Switching Impulse Voltage Residual

Nominal Impulse Voltage Residual

Steep-Front Impulse Current Residual

Current-Withstand Capacity

Creepage Distance

kV

kV

kV

kV

kV

kV

kV

A

mm

(RMS Value)

(RMS Value)

(RMS Value)

Not Less Than

Not Greater Than

Not Greater Than

Not Greater Than

20 Times






(Peak Value)

(Peak Value)

(Peak Value)

(Peak Value)


Y20W1-828/1620W

828

1000

638

1114

1460

1620

1782

8000

33000

Y20W1-888/1700W

888

1000

684

1145

1500

1700

1832

8000

33000

Cognosce tui fornitori
Venditio Online
Ratio praestabilitae tradendae
Tempus responsionis
100.0%
≤4h
Brevis Descriptio Societatis
Locus Operis: 108000m²m² Numerus omnium laborantium: 700+ Summa Annua Exportatio (USD): 150000000
Locus Operis: 108000m²m²
Numerus omnium laborantium: 700+
Summa Annua Exportatio (USD): 150000000
Servitia
Genus Negotii: Design/Fabricatio/Venditio
Categorias Principales: apparatus electrum altum voltus/transformator
Gubernatio vitae
Servitia gestionis curae integralis pro quaestu, usu, conservatione et post-venditionem apparatus electricorum, securitatem operationis, continuationem imperii et usum electricitatis sine cura garantia.
Fornitori instrumentorum praeteritus est certificationem qualificationis platformae et iudicium technicum, ut ex fonte conformitas, professionalitas et fiducia servantur.

Producta Connexa

Cognitio Connexa

  • Accidentia Transformatoris Principalis et Questiones Operationis Gas Luminis
    1. Registri accidentis (XIX Martii, MMXIX)Hora XVI:XIIX die XIX Martii, MMXIX, monitorium background reportavit actionem gas levis transformatoris principis numeri III. Conformiter Codex Operationis Transformatorum Electricitatis (DL/T572-2010), personale operationis et maintenance (O&M) inspectavit statum in situ transformatoris principis numeri III.Confirmatio in situ: Panel non-electricus protectionis WBH transformatoris principis numeri III reportavit actionem gas levis phase B corpus tr
    02/05/2026
  • Culpae et Tractatio Terrae Unipolaris in Lineis Distributionis 10kV
    Characteristica et Instrumenta Detegendi Defectus Terrae Monofasiales1. Characteristica Defectuum Terrae MonofasialiumSigna Centralia Admonitionis:Campanula admonitionis sonat, et lucerna indicativa inscripta „Defectus Terrae in Sectione Omnibus [X] kV [Y]“ accenditur. In systematibus ubi punctum neutrum per bobinam Petersen (bobinam suppressionis arcus) ad terram connectitur, lucerna indicativa „Bobina Petersen Operatur“ etiam accenditur.Indicationes Voltmetri Monitoris Isolationis:Tensio phase
    01/30/2026
  • Modus operationis terre iunctae puncti neutralis pro transformatoribus retis electricitatis 110kV~220kV
    Dispositio modi operis terrae puncti neutralis pro transformatoribus rete electricitatis 110kV~220kV debet exigentias tolerationis insulationis puncti neutralis transformatorum complere, et simul conari ut impedimentum sequentiae nullae stationum transformationis fere immutatum maneat, dum certatur ne impedimentum sequentiae nullae compositum in quocumque puncto raptus circuiti systematis ultra ter impedimentum sequentiae positivae compositum excedat.Pro transformatoribus 220kV et 110kV in novis
    01/29/2026
  • Cur Quare Substationes Lapidem Gravem Calculos et Rupem Fractam Utuntur
    Cur Quare Substationes Utuntur Lapidibus, Gravibus, Piscinis et Saxis Tritis?In stationibus transformationis, instrumenta ut transformatores electricitatis et distributionis, lineae transmissionis, transformatores tensionis, transformatores currentis et commutatores disiunctionis omnia terram exigunt. Praeter terram, nunc profundius explorabimus cur gravia et saxa trita in stationibus transformationis saepe utuntur. Quamquam videantur ordinaria, isti lapides partem criticam iuxtaque functionalem
    01/29/2026
  • Cur autem nucleus transformatoris tantum in uno puncto terram tangere debet Nonne terra multipuncta fidelius est
    Cur ergo nucleus transformatoris terram tangere debet?In operatione, nucleus transformatoris, simul cum structuris, partibus et componentibus metallicis quae fixant nucleum et spiras, in forti campo electrico situs est. Sub influentia huius campi electrici, potentialem relativum altum ad terram comparatum acquirunt. Si nucleus non terra tangitur, differentia potentialis inter nucleum et structuras claudicantes et vas terratum existet, quae possit ad intermitterentiam dismissionem ducere.Praetere
    01/29/2026
  • Intellegere Terram Neutralis Transformatoris
    I. Quid est Punctum Neutrum?In transformatoribus et generatoribus, punctum neutrum est locus specificus in spira ubi absoluta tensio inter hunc locum et singula terminalia externa aequalis est. In diagrammate infra, punctumOrepraesentat punctum neutrum.II. Cur Punctum Neutrum Terrendum Est?Modus connexionis electricae inter punctum neutrum et terram in systemate AC triphasico diciturmodus terrendi puncti neutri. Hic modus directe afficit:Securitatem, fidem et oeconomiciam retelectrici;Selectione
    01/29/2026

Solutiones Relatae

  • Design Solution of 24kV Siccum Aera Insulatum Ring Main Unit
    Combinatio Solidi Insulationis Adiuvantis + Insulationis Aereae Siccae repraesentat directionem pro RMU 24kV. Per requirementa insulationis cum compactitate equilibrata et adiuvante solidum insulationis, testes insulationis sine magnificatione significativa dimensionum inter phasos et inter phasos et terram transigi possunt. Inclusio columnae pole solidificat insulationem pro interruptore vacuo et conductoribus eius coniunctis.Maintinendo spatium phasorum exiens 24kV ad 110mm, intensitas electri
    08/16/2025
  • Optimizatio Design Schematum pro Unitate Circulorum Principalium Aere Insulata 12kV ad Minuendam Probabilitatem Disruptionis Emissionis
    Cum celeri progressus industriae electricitatis, conceptus ecologicus de carbonis minore, energiae servanda, et conservatione ambientis profundissime integratus est in designum et fabricam productorum electricorum pro distributione et generatione electricitatis. Unitas Distributiva Circuli (RMU) est dispositivum electricum clavem in retibus distributionis. Securitas, conservatio ambientis, fides operativa, efficacia energetica, et oeconomia sunt tendentiae inevitabiles in eius progressu. RMUs tr
    08/16/2025
  • Analyse communium problematum in unitatibus principali circuitu isolatis gas 10kV (RMUs)
    Introductio:​​RMUs insulati gaseis 10kV sunt amplissime usitati propter multas suas utilitates, sicut quod sint perfecte clausi, habeant excellentem insulativam qualitatem, non requirant maintenance, sint compacti, et praebent installationem flexibilem et commodam. In hoc stadio, paulatim facti sunt nodus criticus in rete distributionis urbano anulari et iocabuntur partem significativam in systemate distributionis electricitatis. Difficultates in RMUs insulatis gaseis possunt graviter impingere
    08/16/2025
Non invenisti adhuc opportunos fornitoris ut te inveniant Citationem Nunc Accipe
Non invenisti adhuc opportunos fornitoris ut te inveniant
Citationem Nunc Accipe
Inquiry
+86
Click to upload file
Descarica
Obtine Applicatio Commerciale IEE-Business
Utiliza app IEE-Business ad inveniendum apparatus obtinendumque solutiones coniungendum cum peritis et participandum in collaboratione industriale ubique et semper propter totam supportionem tuorum projectorum electricitatis et negotiorum