Serie HD8000 conversor de frecuencia de media tensión de ingeniería

  • 1.65 to 20kV 50/60HZ engineering MV voltage regulation frequency converter
  • 1.65 to 20kV 50/60HZ engineering MV voltage regulation frequency converter

Attributa principalia

Marca RW Energy
Numerus Modeli Serie HD8000 conversor de frecuencia de media tensión de ingeniería
Frequenta nominata 50/60Hz
Series HD8000

Descriptiones productorum a fornitori

Descriptio

Brevis descriptio

1.65kV, 2.4kV, 3.3kV, 4.16kV, 6.6kV, 10kV, 13.8kV, 19.8kV; 8MVA~102MVA (independens), quod ad octo machinas in parallelo supportare potest.

Characteres praestantiae

Design fidei commissum ingenium

  • IGCT culpa et iudicium + protectio pontis brachii transitus technologia

  • Redundantia design et tolerantia culpae design componentum clavium

  • IP54 protectio design, C4-M anti-corrosion design

  • Structura duplex crimped dispositiva potentiae

Modularis design

  • Modularis design componentum clavium

  • Systema intelligentis diagnosticae culpae pro celeri locatione

  • Tempus disassembly moduli phase tantum 15 minutas, faciendo manutenctionem simplicem et celerem

Praestans control

  • Operatio quadrantis quattuor ad satisfaciendum retroactioni energiae electricae et frenorum

  • Adaptabilis ad motor inductionis asynchroni, motor synchronous permanentis magnetis et motor synchronous excitationis electricae

  • Celeris responsus torque dynamicus et functio suppressionis vibrationis torsionalis

  • Modulatio synchrona segmentata motoris ad satisfaciendum requisitionibus amplitudinis celeris regulationis sicut laminatio ferri et ascensor

  • SHEPWM (modulatio latitudinis pulsus cancellationis specifica harmonica)

Adaptabilis

  • Configuratio transmissionis unimotoris / configuratio transmissionis multimotoris

  • Design altitudinis: non requiritur derating ad usum infra 2000m

  • Design adaptabilitatis rete: Systema habet facultatem ad adaptandum imbalanciam rete, harmonicas rete, flicker frequentiae rete, drop transientis rete, et transversalia voltus alti et bassi.

Protocolla communicationis & software sapientis

  • Protocollum communicationis customizabile

  • Systema potentis monitoringi potest monitorare data interna, formae undarum, etc. in tempore reali

  • Proveho hopeInsight pro celeri debugging rete

Technologia level internationalis ducens

  • "Dispositivum AC IGCT magnae potestatis et regulatio velocitatis conversionis orthogonalis frequentiae" et "Technologiae claves et applicationes systematis regulationis velocitatis conversionis orthogonalis frequentiae AC IGCT magnae potestatis" sunt identificatae ut level internationalis advanced, et numerus technologiarum sunt identificatae ut level internationalis ducens

Parametri principales

projectus

Specificationes et data technica

Rectificatio fundamentalis

Frequencia input

45Hz~66Hz

Factor fundamentalis potencie

≥ 95% (basatum super 12 pulsus et supra, currentis nominale, equipatum 2% reactoris input currentis)

Rectificatio PWM

Frequencia input

45Hz~66Hz

Factor

1 (continuo settabilis)

Functio protectionis

Protectio overload, protectio overheat, protectio circuitus brevis, predictio culpae, etc

Inversum

Voltus output

1:1.65kV,2:2.4kV,3:3.3kV, 4:4.16kV,6:6.6kV,

A:10kV,B:13.8kV,C:19.8kV

Frequencia output

0~110Hz (frequencia output superior potest customizari secundum requisitiones)

Accuratia velocitatis stabilis

OLVC:0.2% ; CLVC:0.01%

Velocitas pulsans

OLVC:0.4% ; CLVC:0.2%

Torque initiale

OLVC:150%; CLVC:200%   

Controlis torque

V/F: Supportat ; OLVC: Supportat; CLVC: Yes

Accuratia torque

OLVC:5% ; CLVC: 2% (customizabile)

Tempus responsus torque

≤5ms

Tempus responsus RPM

OLVC:100ms ; CLVC:100ms

Equivalentia drop dynamica

OLVC:0.5%*s ; CLVC:0.25%*s

Machina

efficientia

Quadrans secundus: ≥99% (exclusis transformatoribus rectifieris)

Quadrans quartus: ≥ 98.5% (exclusis transformatoribus rectifieris)

temperatura

Temperatura aquae inlet ≤35°C (extra aquam)

altitudo

≤2000m (2000m~4000m usus diminutus)

Level protectionis

IP54

Methodus refrigerationis

Aqua

Gradus anti-corrosionis

C4-M

 

Bibliotheca Documentorum Rerum
Restricted
Medium-Voltage Engineering Variable Frequency Drive System catalog
Catalogue
English
Consulting
Consulting
Cognosce tui fornitori
Venditio Online
Ratio praestabilitae tradendae
Tempus responsionis
100.0%
≤4h
Brevis Descriptio Societatis
Locus Operis: 30000m² Numerus omnium laborantium: Summa Annua Exportatio (USD): 100000000
Locus Operis: 30000m²
Numerus omnium laborantium:
Summa Annua Exportatio (USD): 100000000
Servitia
Genus Negotii: Design/Fabricatio/Venditio
Categorias Principales: robot/Energia nova/Instrumenta inspectionis/apparatus electrum altum voltus/Apparatus electri bassa tensione/Instrumenta et mensurae
Gubernatio vitae
Servitia gestionis curae integralis pro quaestu, usu, conservatione et post-venditionem apparatus electricorum, securitatem operationis, continuationem imperii et usum electricitatis sine cura garantia.
Fornitori instrumentorum praeteritus est certificationem qualificationis platformae et iudicium technicum, ut ex fonte conformitas, professionalitas et fiducia servantur.

Producta Connexa

Cognitio Connexa

  • Impactus Praejudicialis Bias Directi Currentis in Transformeribus ad Stationibus Energiae Renovabilis Proximis Electrodis Terrae UHVDC
    Impactus DC Bias in Transformeribus ad Stationes Energeticae Renovabiles Proximas Electrodis Terrae UHVDCCum electrum terrae systematis transmissionis Ultra-Alta-Voltura Directa (UHVDC) sit prope stationem energeticae renovabilis, currus reditus per terram fluens potest causare incrementum potentialis terrae circa aream electri. Hoc incrementum potentialis terrae ducit ad mutationem potentialis puncti neutri transformatorum proximorum, inducendo bias DC (vel offset DC) in eorum nucleis. Talis bi
    01/15/2026
  • HECI GCB for Generators – Cepus SF₆ Circuit Breaker
    1. Definitio et Functio1.1 Munus Interruptoris Circuiti GeneratorisInterruptor Circuitus Generatoris (GCB) est punctum disiunctionis controllabile situatum inter generator et transformator incrementalis, servans ut interficium inter generator et rete electricitatis. Principales eius functiones includunt isolationem defectuum lateris generatoris et facilitationem controlis operationis durante synchronizatione generatoris et connectione ad rete. Principium operativum GCB non differt significanter
    01/06/2026
  • Apparatus Distributionis Transformatorisque Experimentatio Inspectio et Conservatio
    1. Manutentio et Inspectio Transformatoris Aperi interruptorem circuitus bassae tensionis (LV) transformatoris in manu, remove fusum alimenti controlis, et pende signum “Noli Claudere” super manubrium commutationis. Aperi interruptorem circuitus altae tensionis (HV) transformatoris in manu, claudi commutatorem terrae, exsolvare totaliter transformatorem, claude armarium interruptoris HV, et pende signum “Noli Claudere” super manubrium commutationis. Pro manutentione transformatoris sicci: primo
    12/25/2025
  • Quomodo Resistentiam Isolationis Transformatorum Distributionis Probes
    In operibus practicis, resistentia insulationis transformatorum distributionis saepe bis metitur: resistentiam inter spiram alti voltaginis (HV) et spiram bassi voltaginis (LV) plus vasum transformatoris, et resistentiam inter spiram LV et spiram HV plus vasum transformatoris.Si ambae mensurationes valores acceptabiles praebent, indicat quod insulatio inter spiram HV, spiram LV, et vasum transformatoris est probata. Si una mensuratio deficiat, testes pairwise resistentiae insulationis inter omne
    12/25/2025
  • Principia Design pro Transformeribus Distributionis in Columna Fixis
    Principia Design Pro Distributionibus Transformerum in Polum Fixis(1) Principia Locorum et DispositionumPlataformae transformerum in polum fixarum debent collocari iuxta centrum oneris aut prope onera critica, secundum principium “parva capacitas, plura loca” ad facilitatem substitutionis et maintenance. Ad distributionem electricitatis domesticam, transformatores triphasici possunt instaurari iuxta necessitatem praesentem et projectiones futurorum incrementorum.(2) Selectio Capacitatis pro Tran
    12/25/2025
  • Solutio Controlis Stridoris Transformatorum pro Diversis Installationibus
    1. Mitigatio sonoris pro camera transformatoris independente in superficie terraeStrategia mitigationis:Primum, fac inspectionem et maintenance cum potestate interrupta, includens renovationem olei insulantis vetustatis, examinationem et consolidationem omnium fixorum, et mundationem pulvis a unitate.Deinde, reficere fundamentum transformatoris vel installare dispositiva isolationis vibrationis—ut gommae vel isolatores springalis—selecta secundum gravitatem vibrationis.Tandem, fortificare insula
    12/25/2025

Solutiones Relatae

  • Systemata automationis distributionis solutio
    Quae sunt difficultates in operatione et maintenance lineae aereae?Difficultas una:Lineae distributionis aerea latam extensionem habent, terrain complicatam, multas ramificationes radiantis et supply power distributum, quod "multa culpa lineae et difficultas in reperiendo errore" producit.Difficultas duo:Reperire manu errorem tempus consumit et laboriosum est. Simul, currentem, tensionem et statum commutationis lineae non potest comprehendere in tempore reali, propter defectum mediorum technicor
    04/22/2025
  • Solutio Integratum Monitorationis Intelligentis Potentiae et Administrationis Efficienciae Energeticae
    Visio generalisHoc opus ad praebendum systema intelligentis monitorii electricitatis (Systema Managementis Electricitatis, PMS) centrum ponit in optimisatione termino ad terminum ressource electricitatis. Per constitutionem framework managementi clausi "monitoring-analysis-decision-execution," iuvat societates a simpliciter "electricitatem utendo" ad intelligenter "electricitatem administrando" transire, tandem ad fines usus energiae securi, efficientis, paucicarbonis et oeconomici perveniens.Po
    09/28/2025
  • Una Nova Solutio Modularis pro Systematibus Generationis Energiae Photovoltaicae et Storaginis
    1. Introductio et Background Investigativus1.1 Status Quodammodo Solaris IndustriaeUt una ex copiosissimis fontibus renovabilium, solis energiae developmentum et usus iam centrum factus est globali transitioni energeticae. Recentibus annis, impulsu politarum mundi, industria photovoltaica (PV) prodigiosa progressione gavisa est. Statistica indicant quod PV industria Sinica vidiit incrementum 168-plex durante "Duodecimo Quinquennio". Ad finem 2015, installata PV capacitas excessit 40,000 MW, tres
    09/28/2025
Non invenisti adhuc opportunos fornitoris ut te inveniant Citationem Nunc Accipe
Non invenisti adhuc opportunos fornitoris ut te inveniant
Citationem Nunc Accipe
Inquiry
Descarica
Obtine Applicatio Commerciale IEE-Business
Utiliza app IEE-Business ad inveniendum apparatus obtinendumque solutiones coniungendum cum peritis et participandum in collaboratione industriale ubique et semper propter totam supportionem tuorum projectorum electricitatis et negotiorum