• Product
  • Suppliers
  • Manufacturers
  • Solutions
  • Free tools
  • Knowledges
  • Experts
  • Communities
Search


HV610 reeks spesiale frekwensie-omskakelaar vir hefning

  • 0 to 600Hz Special frequency converter for lifting

Sleutelkenmerke

Handelmerk Rw Energy
Modelnommer HV610 reeks spesiale frekwensie-omskakelaar vir hefning
Gedraaide frekwensie 50/60Hz
Reeks HV610

Produkbeskrywings van die voorsienier

Beskrywing

Oorsig

Om die toepassingsbehoeftes van kliënte in die hefbranche beter te bevredig, is die produk op 'n hef-toepassing perspektief gebaseer, met funksies soos anti-swaai beheer, anti-losroep beskerming, slip haak beskerming, rembeheer, vertragtingsbeperking, spoed met belasting, makro parameters en ander spesiale funksies geïntegreer. Dit verseker volledig die betroubare, effektiewe, veilige en stabiele werking van hefapparatuur.

Prestasiekenmerke

Spesialisering in kenmerke

  • Anti-swaai beheer, wat swaai van die spreier onderdruk en doeltreffende operasie verseker

  • Real-time aanpassing van die loopspyd volgens die belastingsverandering met die belasting van die last • Haakbeskerming, remdeteksie haak, motoruitset hover beheer

  • Vernuftige posisionering deur samewerking van vertragingsbeperking en stopbeperking

  • Anti-losroep beskerming, wat by 'n vaste spoed opgaan, langsaam versnel en glad opstyg wanneer 'n swaar last gedetekteer word

  • Die ooreenkomstige hefmechanisme kan gekies word volgens die makro ingestelde waarde van die hefparameters

  • Meer as een motor kan geswitch word, en vier stelle motorparameters word intern ondersteun.

Hoë betroubaarheid

  • Onafhanklike lugroete ontwerp van die hele masjien om effektief stofimpuriteite te voorkom • Doeltreffende en akkurate termiese simulasieplatform sagteware

  • Gevorderde termiese toets- en verifikasietegnieke en -toestelle om die teoretiese resultate van termiese ontwerp effektief te verifieer

  • Streng volle belasting- en oorbelasting-verifikasietoetsprosedures

  • Produkte is by hoë temperatuur en belasting geouderdom, wat die fabriekskwaliteit effektief verseker

  • Versterkte roosterplankbeskerming, korrosiebestendig, waterskaars, stofvry, ens

Hoë aanpasbaarheid

  • Wye spanningsbereikontwerp, driefase 380V~480V (-15%~+10%)

  • Ingeboude C3-filter, wat die hoëfrekwensie harmonieke wat deur die frekwensieomsteller gegenereer word, effektief onderdruk

  • Eenvoudige en vriendelike EMC-grondverbreekontwerp, wat die lekstrom na die vloer effektief kan verminder

  • Boekagtige ontwerp, wat die volume van die tradisionele model ongeveer met 40% verminder

  • Die hele masjien kan agter mekaar geïnstalleer word om installasieruimte te spaar.

Uitstekende prestasiebeheer

  • Ondersteuning vir dryfbeheer van driefase asinchronus motor en permanente magneet sinchronus motor

  • Ondersteuning vir V/F-beheer, ooplusvectorisering, geslote lus vectorbeheer

  • Groot starttorque, OLVC: 0.5Hz/150%, CLVC: 0Hz/200%

  • Hoë oorbelastingskapasiteit, 150% nominaalstroom 60s, 180% nominaalstroom 10s

Gemaklik en maklik om te gebruik

  • Standarmasjien van 132kW en meer is toegerus met LED-toetspaneel wat eksterne invoer kan ondersteun

  • Toetspaneel eksterne invoer van 110kW en minder kan toegerus word met 'n onafhanklike LED-toetspaneel

  • Wanneer die frekwensieomsteller begin en stop, kan die motor beheer word deur die rem vast te hou • Meerdere spoedbeheerfunksie, wat 16-spoedbedryf deur die beheerterminal bewerkstellig

  • Nulbedienerfunksie, die motor

  • Willekeurige PWM-diepte om die motor se strengheid te verbeter

  • Koder redundantebewerkstelligningsmodus wat outomaties na OLVC-bewerkstelligning switsover wanneer die koder misluk

Uitbreiding diversifikasie

  • Ondersteuning vir 'n verskeidenheid kodeplaatkaarte, ondersteuning vir I/O-terminal uitbreidingskaarte

  • Ondersteuning vir Profibus-DP, Profinet IO, CANopen, Modbus-TCP/IP, EtherNet IP, Ethercat en ander kommunikasie

  • Ondepandige en vinnige kommissieëring

  •  

    Ondersteuning vir verbinding tot agtergrond sagteware, wat die foute en instellings gemakliker maak

  • Ondersteuning vir gebeurtenis-opname en foute-opname

 

Hoofparameters

project

Specifications and technical data

Power input and output

Input voltage

380V(-15%)~480V(+10%) three-phase

Input power frequency

50Hz/60Hz ±5%

Input voltage imbalance

≤3%

Output voltage

0V~input voltage

Output frequency

0~600Hz

Mainly control performance

Motor type

Asynchronous motor, synchronous motor

Control mode

V/F, OLVC (Open-Loop Vector Control), CLVC (Closed-Loop Vector Control)

speed regulation range

1:10 V/F; 1:100 OLVC; 1:1000 CLVC

Start torque

OLVC:150%(0.5Hz);CLVC:200%(0Hz)

Torque accuracy

≤±5%, under vector control mode

Torque pulsation

≤±5%, under vector control mode

Steady speed accuracy

OLVC: 0.2%; CLVC :0.01%

Torque response

≤5ms, under vector control

acceleration and deceleration time

0.0s~3200.0s;0.0min~3200.0min

Torque increase

0.0%~30.0%

Overload capacity

150%1min/5min、180%10s/5min

VF curve

Straight type, multi-point type

Input frequency resolution

Digital setting 0.01Hz; Analog setting: Maximum frequency ×0.025%

Dedicated features

Anti-shake function

Prevents accidents caused by large swings of the load during acceleration or deceleration

Anti-loose rope protection

Accelerate slowly and rise smoothly according to whether the weight is lifted

Hook protection

After holding the gate, it detects whether the heavy object is hooked, and an alarm is issued, and the motor hovers

Holding the brake control

Control the brake holding device and loosening the brake through the judgment of frequency, current, etc., to avoid accidents such as slipping

Joystick zeroing detection

Determine whether the joystick is in neutral or not

Command reverse control

When the brake control is effective, it supports holding the brake to stop during the forward and reverse switching process, or running directly to the reversal frequency without holding the brake

Accelerate and deceleration switching

Support 3 frequency switching points to switch acceleration and deceleration time

Deceleration limit

Realize simple positioning function, automatic optimization of deceleration time

Voltage suppression

Automatically change the frequency to stabilize the bus voltage to prevent fault reporting

Overload protection

Prevents excessive loads from damaging the equipment

Low-speed operation protection

The main application is not suitable for machines that run at low speed for a long time

Load as you go

Automatically adjust the operating speed according to load changes to improve work efficiency

Macro parameters

According to the on-site application scenario, different lifting mechanisms choose different lifting macros

Basic features:

acceleration and deceleration curves

Straight line, S-curve

Simple PLC, multi-terminal speed

16 speed operation is achieved through the control terminal

Master-slave control

It can realize the master-slave synchronous control function of two or more motors

Automatic voltage adjustment

When the grid voltage changes within a certain range, it can automatically keep the output voltage constant

Multi-motor switching

Four sets of motor parameters, which can realize the switching control of four motors

Overvoltage and overcurrent stall control

Automatic current and voltage limit during operation to prevent frequent overcurrent and overvoltage tripping

Power outage and restart

After the frequency converter is powered off, when it is powered on again, it will automatically run after the set time is reached

Fast current throttling

Avoid frequent overcurrent failures of the frequency converter

Power input and output

Frequency setting method

Operation panel given, UP/DOWN terminal, multi-speed give, terminal pulse given, communication

Analog input terminals

AI1、AI2:0V~10V/ 0 (4)mA~20mA

Digital input terminals

DI1-DI5, 5 programmable digital inputs, optocoupler-isolated, drain/source compatible inputs

The DI5 supports high-speed pulse input with a maximum input frequency of 100kHz

Digital output terminals

open-circuit collector output; Output Voltage Range: 0V~24V; Current load capacity: 50mA

DO1 supports high-speed pulse output, maximum output frequency: 100kHz

Analog output terminals

1 way 0V~10V/0(4)mA~20mA

Relay output

1 contact type: FormC normally open + normally closed

communication

Communication protocol

Modbus RTU (standard); Profibus-DP, Profinet IO, CANopen, Modbus TCP/IP, Ethercat, EtherNet/IP (optional)

Usage environment

altitude

no derating is required within 1000 meters above sea level; At an altitude of 1000 meters ~ 3000 meters, the current must be reduced by 1% for every 100 meters of elevation

Ambient temperature

-25°C~+40°C (40°C to 55°C derating is allowed)

humidity

15%~95%, no condensation

vibration

0.75~110kW is the 3M3 standard, 2Hz&le;f<9Hz, displacement 1.5mm, 9Hz&le;f<200Hz, acceleration 5m/s2

132kW~400kW is the 3M5 standard, 2Hz&le;f<9Hz, displacement 3mm, 9Hz&le;f<200Hz, acceleration 10m/s2

Storage temperature

&minus;40&deg;C~+70&deg;C

Place of use

Indoors, there is no direct sunlight, no flammable and corrosive gases, liquids and conductive particles

Options:

code disk card, communication expansion card, I/O terminal expansion card

Protection function

Short circuit, overcurrent, overload, overvoltage, undervoltage, phase loss, overheating, external faults, etc

Installation method:

Loading machines and containers

Protection level

IP20

Cooling method

Air cooling

FAQ vir
Q: Is die posisionering akkuraat?
A:

Die vertragingslimietfunksie kan eenvoudige posisieë bereik. Dit optimiseer outomaties die vertragings tyd en maak akkurate stops. Die goederes word in die aangewezen plek geplaas sonder afwyking of beweging, wat die doeltreffendheid verbeter en die bediening gemakliker maak.

Q: Kan ons die staal tou verhoed om los te raak?
A:

Uitgerus met 'n anti-losmaak tou beskerming, behou dit 'n vaste spoed tydens die opstyg, versnel stadig, en styg stabiel. Na die opsporing van swaar voorwerpe word die spoed outomaties aangepas om losmaak van die staal tou te vermy, wat die hefproses veiliger en betroubaarder maak, en die bediening eenvoudiger.

Q: Is die anti sway funksie werklik nuttig?
A:

Dit moet wees! Druk outomaties die swaai van goederes tydens die optil en pas die spoed in real-time aan. Die kraan til swaar voorwerpe op sonder trilling of skudding, wat veilig en doeltreffend is, vermy skade aan goederes of beseer personeel, en maak optiloperasies veiliger.

Ken u lewerancier
Online winkel
Punte tydlewering
Reaksietyd
100.0%
≤4h
Bedryfsomsig
Werkplek: 30000m² Totale personeel: Hoogste Jaarlikse Uitvoer (VSA): 100000000
Werkplek: 30000m²
Totale personeel:
Hoogste Jaarlikse Uitvoer (VSA): 100000000
Dienste
Geselsaakstype: Ontwerp/Vervaardiging/Verkope
Hoofdskategorieë: robot/Nuwe Energie/Toerusting vir inspeksie/Hoëspanningstoerusting/Laagspanningstoerusting/Meetinstrumente
Levenslange garantiebeheerder
Heel Lewensorg Sorg Dienste vir toerustingverskaffing, gebruik, instandhouding en naverkoop, om veilige bedryf van elektriese toerusting, deurlopende beheer en sorgvrye elektrisiteitsverbruik te verseker
Die toerustingverskaffer het platformkwalifikasiesertifisering en tegniese evaluering deurgegaan, wat aan die bron nakoming, professionele standaarde en betroubaarheid verseker.

Verwante produkte

Verwante Kennis

  • Fouten en Handhaving van Enkelefasig Gronding in 10kV Verspreidingslyne
    Kenmerke en opsporingsapparatuur vir enkelfase-grondsluitingsfoute1. Kenmerke van enkelfase-grondsluitingsfouteSentrale waarskuwingsseine:Die waarskuwingklokkie lui, en die aanwyslamp met die etiket “Grondsluiting op [X] kV-busafdeling [Y]” gaan aan. In stelsels met ’n Petersen-kolf (boogonderdrukkingkolf) wat die neutraalpunt grond, gaan die “Petersen-kolf in werking”-aanwyslamp ook aan.Aanwysings van isolasie-toepassingsvoltmeter:Die spanning van die gefouteerde fase da
    01/30/2026
  • Distribusie-toerusting transformator toetsing inspeksie en instandhouding
    1.Transformer Onderhoud en Inspeksie Oop die lae-spannings (LV) skakelaar van die transformer wat onderhoud ontvang, verwyder die beheerkracht fuse, en hang 'n waarskuwingsteken "Do Not Close" op die skakelhandvat. Oop die hoë-spannings (HV) skakelaar van die transformer wat onderhoud ontvang, sluit die aarding skakelaar, laai die transformer volledig af, sluit die HV skakelpaneel toe, en hang 'n waarskuwingsteken "Do Not Close" op die skakelhandvat. Vir droogtype transformer onderhoud: eers sko
    12/25/2025
  • Hoe om die Isolasiestand van Verteilings-transformers te Toets
    In praktiese werk word die isolasieweerstand van verspreidingstransformators gewoonlik twee keer gemeet: die isolasieweerstand tussen die hoë-spanning (HV) winding en die lae-spenning (LV) winding plus die transformatortank, en die isolasieweerstand tussen die LV-winding en die HV-winding plus die transformatortank.As beide metings aanvaarbare waardes lewer, dui dit aan dat die isolasie tussen die HV-winding, LV-winding en transformatortank gekwalifiseer is. As een van die metings misluk, moet p
    12/25/2025
  • Ontwerp Beginsels vir Standaardverdelingstransformateurs
    Ontwerp Beginsels vir Stasie-gebaseerde Verteilings-transformers(1) Lokasie en Uitleg BeginselsStasie-gebaseerde transformerplatforms moet naby die laad middelpunt of naby kritiese lae geleë word, volgens die beginsel van “klein kapasiteit, verskeie plekke” om toerustingvervanging en -onderhoud te vergemaklik. Vir woonstede-elektrisiteitsvoorsiening kan driefase transformers naby geïnstalleer word op grond van huidige behoefte en toekomstige groei-prognoses.(2) Kapasiteitskeuse vir Driefase Stas
    12/25/2025
  • Risikoidentifisering en beheermaatreëls vir die vervanging van verspreidingstransformateurs
    1.Elektriese Skok Risikovoorkoming en BeheerVolgens tipiese ontwerpstandaarde vir verspreidingsnetwerkbegraadsing is die afstand tussen die transformator se uitskop-sikkerheidsknip en die hoëspanningspoort 1,5 meter. Indien ’n kraan gebruik word vir vervanging, is dit dikwels onmoontlik om die vereiste minimum veiligheidsafstand van 2 meter tussen die kraanarm, hysgereedskap, bande, staalkabels en die 10 kV-aktiewe dele te handhaaf, wat ’n ernstige risiko van elektriese skok inhou.Beheermaatreël
    12/25/2025
  • Analise van Algemene Foute en Oorsake tydens Rutienerondtekeninge van Verspreidingstransformasies
    Algemene Foute en Oorsake tydens Routine-inspeksie van Verteilings-transformersAs die eindkomponent van kragverspreidings- en -verdelingstelsels speel verteulings-transformers 'n kritiese rol in die voorsiening van betroubare elektrisiteit aan eindgebruikers. Baie gebruikers het egter beperkte kennis van kragtoerusting, en routinematige instandhouding word dikwels sonder professionele ondersteuning uitgevoer. Indien enige van die volgende toestande waargeneem word tydens die operasie van die tra
    12/24/2025
Nog nie die regte verskaffer gevind nie? Laat goedgekeurde verskaffers jou vind. Kry Praatskaart Nou
Nog nie die regte verskaffer gevind nie? Laat goedgekeurde verskaffers jou vind.
Kry Praatskaart Nou
Stuur navraag
+86
Klik om lêer op te laai
Laai af
Kry die IEE-Business-toepassing
Gebruik die IEE-Business app om toerusting te vind kry oplossings verbind met kenners en neem deel aan bedryfsamenwerking waar en wanneer ook al volledig ondersteunend van jou kragprojekte en besigheidsgroei