Difference Between Current Transformer & Potential Transformer

Edwiin
Edwiin
Field: Power switch
China

For long-distance electrical power transmission, the voltage and current levels are extremely high, making direct measurement with conventional meters impossible. Instrument transformers, including current transformers (CTs) and potential transformers (PTs), are used to step down these levels to safe magnitudes, enabling measurement with standard meters.

What is a Transformer?

A transformer is an electrical device that transfers energy between circuits via mutual induction. It consists of two magnetically coupled yet electrically isolated coils—primary and secondary—designed to adjust voltage and current levels without altering frequency. Transformers serve diverse applications, including power transformers, autotransformers, isolation transformers, and instrument transformers. Among these, current transformers and potential transformers are specialized instrument transformers for measuring high currents and voltages in power lines.

Current Transformer (CT)

A current transformer (CT) is an instrument transformer that reduces high currents to low levels, allowing measurement with a standard ammeter. It is specifically designed for quantifying high-current flows in power transmission lines.

A current transformer (CT) is a step-up transformer that reduces primary current while increasing secondary voltage, stepping down high currents to just a few amperes—levels measurable by standard ammeters. Crucially, its secondary voltage can become extremely high, necessitating a strict operational rule: the CT secondary must never be left open-circuited while primary current is flowing. CTs are connected in series with the power line carrying the current to be measured.

Potential Transformer (PT/VT)

A potential transformer (PT, also called a voltage transformer or VT) is an instrument transformer designed to reduce high voltages to safe, measurable levels for standard voltmeters. As a step-down transformer, it converts high voltages (ranging up to hundreds of kilovolts) to low voltages (typically 100–220 V), which can be directly read by conventional voltmeters. Unlike CTs, PTs feature low secondary voltages, allowing their secondary terminals to be safely left open-circuited without risk. PTs are connected in parallel with the power line carrying the voltage to be measured.

Beyond voltage reduction, a potential transformer (PT) provides electrical isolation between high-voltage power lines and low-voltage measurement circuits, enhancing safety and preventing interference in the metering system.

Types of Potential Transformers

There are two primary configurations:

  • Conventional Electromagnetic Transformer

    • Relies on traditional magnetic coupling between primary and secondary windings.

    • Challenges: High-voltage applications require extensive insulation, leading to significant costs and bulk due to the need for robust dielectric materials.

  • Capacitive Potential Transformer (CPT)

    • Employs a capacitor voltage divider circuit to first reduce the high voltage before it reaches the transformer.

    • Advantages: Minimizes insulation requirements and cost by leveraging capacitive voltage division rather than relying solely on transformer windings, making it more suitable for extra-high-voltage (EHV) systems.

Comparison between Current Transformer and Voltage or Potential Transformer

Give a tip and encourage the author!
Recommended
What are the safety precautions and guidelines for using AC load banks?
What are the safety precautions and guidelines for using AC load banks?
AC load banks are electrical devices used to simulate real-world loads and are widely applied in power systems, communication systems, automation control systems, and other fields. To ensure personal and equipment safety during use, the following safety precautions and guidelines must be observed:Select an appropriate AC load bank: Choose an AC load bank that meets actual requirements, ensuring its capacity, voltage rating, and other parameters satisfy the intended application. Additionally, sel
Echo
11/06/2025
What should be noted when installing a Type K thermocouple?
What should be noted when installing a Type K thermocouple?
Installation precautions for Type K thermocouples are critical to ensuring measurement accuracy and extending service life. Below is an introduction to the installation guidelines for Type K thermocouples, compiled from highly authoritative sources:1.Selection and Inspection Select the appropriate thermocouple type: Choose the right thermocouple based on the temperature range, medium properties, and required accuracy of the measurement environment. Type K thermocouples are suitable for temperatu
James
11/06/2025
 Causes and Preventive Measures of Fire and Explosion in Oil Circuit Breakers
Causes and Preventive Measures of Fire and Explosion in Oil Circuit Breakers
Causes of Fire and Explosion in Oil Circuit Breakers When the oil level in an oil circuit breaker is too low, the oil layer covering the contacts becomes too thin. Under the effect of the electric arc, the oil decomposes and releases flammable gases. These gases accumulate in the space beneath the top cover, mixing with air to form an explosive mixture, which can ignite or explode under high temperature. If the oil level inside the tank is too high, the released gases have limited space to expan
Felix Spark
11/06/2025
THD Measurement Error Standards for Power Systems
THD Measurement Error Standards for Power Systems
Error Tolerance of Total Harmonic Distortion (THD): A Comprehensive Analysis Based on Application Scenarios, Equipment Accuracy, and Industry StandardsThe acceptable error range for Total Harmonic Distortion (THD) must be evaluated based on specific application contexts, measurement equipment accuracy, and applicable industry standards. Below is a detailed analysis of key performance indicators in power systems, industrial equipment, and general measurement applications.1. Harmonic Error Standar
Edwiin
11/03/2025
Send inquiry
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.