What is the Maintenance of Transformers ?

Encyclopedia
Field: Encyclopedia
0
China

What is  the Maintenance of Transformers ?


Maintenance of transformers is essential to ensure their safe, stable and efficient operation, and the following are some common maintenance measures:


Periodic inspection


Appearance check: Check whether the transformer shell is damaged, deformed, and leaking oil.


Oil temperature check: Use an oil temperature gauge to measure the oil temperature and ensure that it is within the normal range.


Oil level check: Observe the oil level in the oil pillow. If the oil level is too low, the transformer oil should be added in time.


Sound check: Listen to the sound of the transformer when it is running. Normally, it should be a uniform humming sound. Abnormal sound may indicate a fault.


Cleaning and ventilation


Regularly clean the dust and dirt on the transformer shell and radiator to ensure good heat dissipation and ventilation.


Electrical test


The insulation resistance test is carried out regularly to check the insulation performance of the winding.Measure the DC resistance of the winding to determine whether there is a short circuit or open circuit in the winding.


Tap-changer maintenance


Check whether the tap changer is in good contact and operates flexibly.

Perform switching test and check on the tap-changer according to the specified period.


Gas relay inspection


Periodically check the gas relay for gas buildup.Test the operational reliability of the gas relay.


Dehumidifier maintenance


Check whether the moisture absorbent (usually silica gel) in the moisture absorbent is discolored, and if it is discolored, it should be replaced in time.


Cooling system maintenance


For air-cooled transformers, check whether the fan is operating normally and whether there is abnormal noise.For water-cooled transformers, check whether the water flow, pressure and temperature are normal.


Fastening part


Check whether the connection bolts and leads of the transformer are tight to prevent loosening.


Oil quality detection


Transformer oil is regularly extracted for testing to detect the breakdown voltage, acid value, water content and other indicators of the oil. If there is deterioration, it should be treated or replaced in time.


Recording and analysis


Establish maintenance records to record the contents, discovered problems, and solutions of each maintenance in detail.Operational data and maintenance records are analyzed to identify potential problems in advance and take preventive action.


Follow operating procedures


Before maintenance, ensure that the transformer is powered off and take reliable grounding measures by strictly following the relevant operation rules and safety regulations.


Emergency treatment plan


Develop emergency plans for possible transformer failures and emergencies to ensure that emergency situations can be handled quickly and effectively.


Give a tip and encourage the author!

Recommended

Classification of Equipment Defects for Relay Protection and Safety Automatic Devices in Substations
In daily operations, various equipment defects are inevitably encountered. Whether maintenance personnel, operation and maintenance staff, or specialized management personnel, all must understand the defect classification system and adopt appropriate measures according to different situations.According to Q/GDW 11024-2013 "Operation and Management Guide for Relay Protection and Safety Automatic Devices in Smart Substations," equipment defects are classified into three levels based on severity an
12/15/2025
Under What Conditions Will the Line Circuit Breaker Auto-Reclosing Signal Be Locked Out?
The line circuit breaker auto-reclosing signal will be locked out if any of the following conditions occur:(1) Low SF6 gas pressure in circuit breaker chamber at 0.5MPa(2) Insufficient energy storage in circuit breaker operating mechanism or low oil pressure at 30MPa(3) Busbar protection operation(4) Circuit breaker failure protection operation(5) Line distance protection zone II or zone III operation(6) Short lead protection operation of circuit breaker(7) Presence of remote tripping signal(8)
12/15/2025
Application of Auto-Reclosing Residual Current Protective Devices in Lightning Protection for Communication Power Supplies
1. Power Interruption Problems Caused by RCD False Tripping During Lightning StrikesA typical communication power supply circuit is shown in Figure 1. A residual current device (RCD) is installed at the power supply input terminal. The RCD primarily provides protection against electrical equipment leakage currents to ensure personal safety, while surge protective devices (SPDs) are installed on power supply branches to protect against lightning intrusions. When lightning strikes occur, the senso
12/15/2025
Reclosing Charge Time: Why Does Reclosing Require Charging? What Effects Does Charging Time Have?
1. Function and Significance of Reclosing ChargingReclosing is a protective measure in power systems. After faults such as short circuits or circuit overloads occur, the system isolates the faulty circuit and then restores normal operation through reclosing. The function of reclosing is to ensure continuous operation of the power system, improving its reliability and safety.Before performing reclosing, the circuit breaker must be charged. For high-voltage circuit breakers, the charging time is g
12/15/2025
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.