Safety Precautions for Electrical System

Electrical4u
Field: Basic Electrical
0
China

Electrical Safety Precautions

Actual safety requires whole hearted cooperation, from all levels of workers involved in the work. It is need not to say, that all the people engaged in the electrical work should well aware of all safety rules and regulations related to the work they are executing. The workers executing the work should be extremely disciplined. Electrical work should not be done by wearing loose dresses.

Before starting the work, the working place should be made neat and clean. The place should also be sufficiently illuminated before work. All levels of voltage should be considered equally dangerous. Even the voltage levels which cannot produce electrical shock should also not be ignored. We shall first confirm the circuit is dead before touching it for repairing maintenance and any others works.


    • We have to switch off, isolate and properly earth the circuit before doing any work with the circuit.

    • We shall only execute the work after getting properly issued work permit from the concerned operating personal.

    • The work permit can only be issued after making the circuit completely dead, isolated and earthed.

    • We must display Danger Board at the place of work.

    • We should not allow any unauthorized person to enter in the working place.

    • We should not put any new equipment into the service without necessary testing by authority.

    • All electrical equipments, bays, circuits, should be identified by properly viewable labels to avoid any mistake.

personal protective equipments

  • We should not work on electrical circuit during heavy lightning storm.

  • We should wear shoes having sewn soles, preferably insulated rubber soles.

  • We should not wear suspenders, arm bands, with metal buckets or other metal parts. We also do not wear metal key chain or metal keepers for key rings or watch rings outside the clothing during work. We should always, take extra precaution while work in extra damp area.

  • When there is a hurry to do the work, the tired and exhausted workers should be avoided to do so.

  • We should not toss the tools or working materials to other person. It is better to deliver the tools and materials hand to hand.

  • We should not keep any tools at the edge of equipment cabinet or structure from where these may fall off.

  • We should not do anything which may startle the person working in hazardous condition.

Statement: Respect the original, good articles worth sharing, if there is infringement please contact delete.

Give a tip and encourage the author!

Recommended

HECI GCB for Generators – Fast SF6 Circuit Breaker
1.Definition and Function1.1 Role of the Generator Circuit BreakerThe Generator Circuit Breaker (GCB) is a controllable disconnect point located between the generator and the step-up transformer, serving as an interface between the generator and the power grid. Its primary functions include isolating generator-side faults and enabling operational control during generator synchronization and grid connection. The operating principle of a GCB is not significantly different from that of a standard c
01/06/2026
Design Principles for Pole-Mounted Distribution Transformers
Design Principles for Pole-Mounted Distribution Transformers(1) Location and Layout PrinciplesPole-mounted transformer platforms should be located near the load center or close to critical loads, following the principle of “small capacity, multiple locations” to facilitate equipment replacement and maintenance. For residential power supply, three-phase transformers may be installed nearby based on current demand and future growth projections.(2) Capacity Selection for Three-Phase Pole-Mounted Tr
12/25/2025
Transformer Noise Control Solutions for Different Installations
1.Noise Mitigation for Ground-Level Independent Transformer RoomsMitigation Strategy:First, conduct a power-off inspection and maintenance of the transformer, including replacing aged insulating oil, checking and tightening all fasteners, and cleaning dust from the unit.Second, reinforce the transformer foundation or install vibration isolation devices—such as rubber pads or spring isolators—selected based on the severity of vibration.Finally, strengthen sound insulation at weak points of the ro
12/25/2025
Rockwill Passes Single-Phase Ground Fault Test for Smart Feeder Terminal
Rockwill Electric Co., Ltd. has successfully passed the real-scenario single-phase-to-ground fault test conducted by the Wenzhou of China Electric Power Research Institute for its DA-F200-302 hood-type feeder terminal and integrated primary-secondary pole-mounted circuit breakers—ZW20-12/T630-20 and ZW68-12/T630-20—receiving an official qualified test report. This achievement marks Rockwill Electric as a leader in single-phase ground fault detection technology within distribution networks.The DA
12/25/2025
Send inquiry
+86
Click to upload file

IEE Business will not sell or share your personal information.

Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.