Key attributes

Brand ROCKWILL
Model NO. Surge Arresters 160 to 500kV High Strength Polymer Housed Surge Arresters
Rated voltage 550kV
Series code X
Series YH10WZH/X
Description

Overview

Standard YH10WZ, PH3 and PH4 station class arresters are available for use on system voltages from 22.86 kV to 500 kV (24 kV max to 550 kV max). They offer an attractive alternative to porcelain housed arresters (MVN family), without sacrificing any reduction in protective capability or energy handling capability, for cases where the high mechanical strength of porcelain is not required and lower weight would be an advantage. Additionally, the YH10WZ, PH3 and PH4 families (up to 230kV MCOV) meet the requirements for High Seismic Performance per IEEE Standard 693-2018.

YH10WZH arresters are available for use on system voltages from 161 to 500 kV. These arresters offer a high strength alternative to the YH10WZ arresters, without sacrificing protective capability or energy handling capability.

Construction:

 "Tube" design, using fiberglass reinforced epoxy tube overmolded with silicone rubber weathershed housing
    Single column of MOV discs and aluminum spacers (as required) centrally located within housing
    Disc column held under high spring compression between ductile iron end fittings affixed to housing
    Directional pressure relief system built integrated into end fittings

At-a-Glance:

High leakage distance designs (standard designs at least 28% more leakage distance than IEEE C62.11 minimum); higher leakage distance designs available for high pollution areas
    Up to 47% lighter than comparable porcelain arresters
    Resilient polymer housing resistant to mechanical damage
    Tested to 63kA rated short circuit current; can handle reclosures with no concern for housing fragmentation

Technology parameters

YH10WZX Electrical Characteristics

Standard Arrester Catalog Number Duty Cycle Rating (kV) MCOV (kV) Temporary overvoltage capability (kVrms) Maximum steep current impulse residual voltage (kV) Maximum switching impulse residual voltage (kV) Maximum switching impulse residual voltage (kV)
1s 10s 1.5kA 3kA 5kA 10kA 20kA 40kA
YH10WZH144GA115 144 115 170 163 390 282 290 303 315 335 363 399
YH10WZH168GA131 168 131 194 186 445 321 331 345 358 382 413 455
YH10WZH172GA140 172 140 207 199 475 343 353 368 383 408 442 486
YH10WZH180GA144 180 144 213 204 489 353 363 379 394 420 454 500
YH10WZH192GA152 192 152 225 216 516 373 384 400 416 443 480 528
YH10WZH240GA190 240 190 281 269 645 466 480 500 524 559 599 660
YH10WZH258GA209 258 209 309 296 709 532 528 550 572 609 659 726
YH10WZH264GA212 264 212 313 301 719 540 535 558 580 618 669 736
YH10WZH276GA220 276 220 325 312 746 560 555 579 602 641 694 764
YH10WZH288GA230 288 230 340 326 780 586 581 605 629 671 726 799
YH10WZH294GA235 294 235 347 333 797 598 593 618 643 685 741 816
YH10WZH312GA245 312 245 362 347 831 624 618 645 670 714 773 851
YH10WZH396GA318 396 318 470 451 1192 810 803 837 870 927 1003 1005
YH10WZH420GA335 420 335 495 475 1255 853 846 881 916 977 1057 1064
YH10WZH444GA353 444 353 522 501 1323 899 891 929 966 1029 1114 1126

The YH10WZX arresters are lightweight and are more resistant to fragmenting than traditional porcelain arresters. YH10WZX arresters are typically applied to system voltages higher than 500 kV where the energy requirements are higher than required for lower voltage systems.

YH10WZX Physical Characteristics

Standard Arrester Catalog Number Duty Cycle Rating (kV) MCOV (kV) Creepage Distance - Inches (mm) Total Height - Inches (mm) Recommended Minimum Clearance - Inches (mm) Net Weight - Pounds (kg) Drawing Figure
Phase to Ground Phase to Phase
YH10WZH144GA115AA 144 115 184 (4676) 68.9 (1750) 25.1 (638) 28.9 (734) 346 (157) 1
YH10WZH168GA131AA 168 131 184 (4676) 68.9 (1750) 28.8 (732) 33.1 (841) 350 (159) 1
YH10WZH172GA140AA 172 140 184 (4676) 68.9 (1750) 30.9 (785) 35.4 (899) 353 (160) 1
YH10WZH180GA144AA 180 144 225 (5704) 78.8 (2001) 31.8 (808) 36.5 (927) 401 (182) 2
YH10WZH192GA152AA 192 152 225 (5704) 78.8 (2001) 33.6 (853) 38.6 (980) 404 (184) 2
YH10WZH240GA190AA 240 190 285 (7230) 112 (2856) 42.5 (1080) 48.5 (1232) 607 (276) 3
YH10WZH258GA209AA 258 209 285 (7230) 112 (2856) 46.9 (1191) 53.5 (1359) 614 (279) 3
YH10WZH264GA212AA 264 212 285 (7230) 112 (2856) 47.6 (1209) 54.3 (1379) 615 (280) 3
YH10WZH276GA220AA 276 220 285 (7230) 112 (2856) 49.4 (1255) 56.4 (1433) 617 (280) 3
YH10WZH288GA230AA 288 230 326 (8291) 122 (3108) 51.7 (1313) 59.0 (1499) 651 (296) 3
YH10WZH294GA235AA 294 235 326 (8291) 122 (3108) 52.9 (1344) 60.3 (1532) 652 (296) 3
YH10WZH312GA245AA 312 245 326 (8291) 122 (3108) 55.2 (1402) 62.9 (1598) 656 (298) 3
YH10WZH396GA318AA 396 318 449 (11408) 152 (3862) 72.1 (1831) 82.1 (2085) 828 (376) 3
YH10WZH420GA335AA 420 335 469 (11913) 176 (4470) 76.1 (1933) 86.5 (2197) 993 (451) 4
YH10WZH444GA353AA 444 353 469 (11913) 176 (4470) 80.2 (2037) 91.2 (2316) 998 (454) 4

These arresters are typically applied to system voltages higher than 500 kV where the energy requirements are higher than required for lower voltage systems. If a high energy rated arrester is required for a lower system voltage, Hubbell Power Systems can provide these. Please contact your Hubbell Power Systems Representative at 1.573.682.5521 for more information.

YH10WZX Electrical Characteristics

Standard Arrester Catalog Number Duty Cycle Rating (kV) MCOV (kV) Temporary overvoltage capability (kVrms) Maximum steep current impulse residual voltage (kV) Maximum switching impulse residual voltage (kV) Maximum lightning impulse residual voltage (kV)
1s 10s 20kA 2kA 1.5kA 3kA 5kA 10kA 20kA 40kA
YH10WZX396GA318AA 396 318 462 442 1018 748 742 773 804 857 927 1021
YH10WZX420GA335AA 420 335 487 466 1072 788 781 815 847 903 977 1075
YH10WZX444GA353AA 444 353 513 491 1130 831 823 858 892 951 1029 1133
YH10WZX588GA470AA 588 470 541 517 1190 875 868 905 940 1002 1085 1194

YH10WZX Physical Characteristics

Standard Arrester Catalog Number Duty Cycle Rating (kV) MCOV (kV) Creepage Distance - Inches (mm) Total Height - Inches (mm) Recommended Minimum Clearance - Inches (mm) Net Weight - Pounds (kg) Drawing Figure
Phase to Ground Phase to Phase
YH10WZX396GA318AA 396 318 449 (11408) 152 (3862) 67.0 (1702) 77.0 (1956) 1080 (491) 3
YH10WZX420GA335AA 420 335 469 (11913) 176 (4470) 71.0 (1803) 81.0 (2057) 1285 (584) 4
YH10WZX444GA353AA 444 353 469 (11913) 176 (4470) 75.0 (1905) 85.0 (2159) 1294 (588) 4
YH10WZX588GA470AA 588 470 736 (18694) 259 (6579) 100 (2540) 114 (2896) 1847 (840) 5

Know your supplier

Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 108000m² Total staff: 700+ Highest Annual Export(usD): 150000000
Services
Business Type: Design/Manufacture/Sales
Main Categories: Medium and High Voltage Switchgear/Power and Distribution Transformers/Instrument Transformers and Sensors/Lightning Protection and Electrical Insulation/Substations and E-Houses/Electrical Panel and Controlgear
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.
Login
or continue with
New here?
Register