| Marca | ROCKWILL |
| Serie | JDS |
Description
As a pioneer and the first dedicated original manufacturer in China's earthing transformer industry, decades of in-depth technical cultivation have enabled us to accumulate strong strength and even establish the original standards for industry development. From breakthroughs in core technology R&D to large-scale mass production and delivery, we have built an end-to-end independent ecosystem. Leveraging leading and stable product performance as well as extremely reliable quality, we have become a trusted choice in the field of power grid construction.
This three - phase 11kV/22kV grounding transformer is tailor - made for medium - voltage power grids. By creating an artificial neutral point, it accurately achieves the grounding protection function and is suitable for various distribution system scenarios. When facing single - phase grounding faults, it can effectively handle them, building a solid defense for the stable operation of urban power grids and industrial power facilities, and ensuring the reliable power supply of the power system.
Main technical parameter
Some of these earthing transformers cover voltage levels including:3.3kV / 6kV / 11kV / 15kV / 20kV / 22kV / 30kV / 33kV / 34.5kV / 36kV / 44kV / 66kV / 88kV / 110kV / 132kV / 145kV / 150kV / 220kV / 275kV / 330kV / 400kV, etc. The current withstand time ranges from 1s, 2s, 3s, 5s, 6s, 8s, 9s, 10s, 30s, 60s, 1hour to 2hours, and customization is available.
Number of phases |
Three rows |
Output voltage |
400V |
Frequency |
50/60Hz |
Input voltage |
11kV 20kV 22kV 30kV 33KV 34.5kV 36kV |
High pressure rating |
11KV/22KV/33KV |
Low pressure rating |
0.4 KV |
Number of coils |
Three Windings |
Link category |
Dyn11 Yyno |
Coil structure |
toroidal |
Certification |
IEC60076 |
Insulation level: |
Dyn11 Yyno |
Application |
Industrial Equipments |
Standard |
IEC60076 |
Use |
Power transformer |
Class |
Oil - Immersed Transformer |
Product name |
Grounding Transformer |
Application Environment Description
Neutral Grounding Systems:Suitable for ungrounded, resistance-grounded, or arc-suppression-coil grounded medium-voltage distribution networks. Limits fault current and improves power supply reliability.
Harsh Physical Environments:IP54/IP56 protection rating, resistant to salt mist and dust. Suitable for altitudes up to 3000m and ambient temperatures from -25°C to +45°C.
Space-Constrained Locations:Compact dry-type design suitable for confined spaces such as underground substations, data centers, and ship engine rooms.
New Energy and Industrial Applications:Neutral grounding protection for systems including wind/solar power plants, rail transit, mining facilities, and oil platforms.
Special Electrical Environments:Compatible with systems containing harmonic pollution, frequent start-stop loads, and smart grids requiring coordination with protection devices.
Il tempo di resistenza al guasto si riferisce al massimo tempo che un trasformatore di messa a terra può resistere agli stress termici e meccanici generati dalla corrente di guasto senza subire danni, alla capacità breve nominale. È la base fondamentale per la progettazione dell'isolamento e della struttura. Gli standard IEEE 32 e IEC 60076-5 specificano quattro tipi di durate standard: ① 10 secondi: adatto ai sistemi di protezione rapida (come la protezione differenziale a fibra ottica), dove i guasti possono essere isolati entro 10 secondi; ② 30 secondi: il livello di resistenza più diffuso, adatto al tempo di azione della protezione a relè di molte reti di distribuzione e sistemi di trasmissione; ③ 60 secondi: utilizzato per i vecchi sistemi o le reti elettriche complesse con tempi di azione della protezione lunghi; ④ 1 ora: applicabile solo ai sistemi di messa a terra ad alta resistenza, dove la corrente di guasto è piccola ma richiede un monitoraggio a lungo termine.