Transformateurs de mise à la terre/triphasés 11kV 22kV

  • Customization Three - phase 11kV 20kV 22kV 30kV grounding/earthing transformers Original Manufacturer
  • Customization Three - phase 11kV 20kV 22kV 30kV grounding/earthing transformers Original Manufacturer

Attributs clés

Marque ROCKWILL
Série JDS
Description

Description

As a pioneer and the first dedicated original manufacturer in China's earthing transformer industry, decades of in-depth technical cultivation have enabled us to accumulate strong strength and even establish the original standards for industry development. From breakthroughs in core technology R&D to large-scale mass production and delivery, we have built an end-to-end independent ecosystem. Leveraging leading and stable product performance as well as extremely reliable quality, we have become a trusted choice in the field of power grid construction.

This three - phase 11kV/22kV grounding transformer is tailor - made for medium - voltage power grids. By creating an artificial neutral point, it accurately achieves the grounding protection function and is suitable for various distribution system scenarios. When facing single - phase grounding faults, it can effectively handle them, building a solid defense for the stable operation of urban power grids and industrial power facilities, and ensuring the reliable power supply of the power system.

Features

  • Flexible Voltage Adaptation: Supports 11kV and 22kV voltage systems, accurately matches the specifications of common medium - voltage power grids, is widely adaptable to diverse power application scenarios, and has strong compatibility.

  • Intelligent Fault Management: When encountering single - phase faults, it quickly suppresses arc - grounding overvoltages, greatly reduces fault currents, reduces the risk of damage to power equipment, and improves the operation and maintenance efficiency of the system.

  • Reliable and Robust Structure: Adopts high - quality iron cores, durable windings, and is matched with a robust shell. It effectively resists the erosion of harsh environments such as moisture and dust, ensures the long - term stable operation of the equipment, and reduces maintenance costs.

  • Comprehensive Safety Assurance: Stably provides neutral point grounding, prevents voltage fluctuations and insulation faults from the source, safeguards the safety of the power grid and associated electrical equipment, and builds a solid foundation for the safety of the power system.

Main technical parameter

Some of these earthing transformers cover voltage levels including:3.3kV / 6kV / 11kV / 15kV / 20kV / 22kV / 30kV / 33kV / 34.5kV / 36kV / 44kV / 66kV / 88kV / 110kV / 132kV / 145kV / 150kV / 220kV / 275kV / 330kV / 400kV, etc. The current withstand time ranges from 1s, 2s, 3s, 5s, 6s, 8s, 9s, 10s, 30s, 60s, 1hour to 2hours, and customization is available.

Number of phases

Three rows

Output voltage

400V

Frequency

50/60Hz

Input voltage

11kV  20kV 22kV 30kV 33KV 34.5kV 36kV

High pressure rating

11KV/22KV/33KV

Low pressure rating

0.4 KV

Number of coils

Three Windings

Link category

Dyn11 Yyno

Coil structure

toroidal

Certification

IEC60076

Insulation level:

Dyn11 Yyno

Application

Industrial Equipments

Standard

IEC60076

Use

Power transformer

Class

Oil - Immersed Transformer

Product name

Grounding Transformer

Application Environment Description

  • Neutral Grounding Systems:Suitable for ungrounded, resistance-grounded, or arc-suppression-coil grounded medium-voltage distribution networks. Limits fault current and improves power supply reliability.

  • Harsh Physical Environments:IP54/IP56 protection rating, resistant to salt mist and dust. Suitable for altitudes up to 3000m and ambient temperatures from -25°C to +45°C.

  • Space-Constrained Locations:Compact dry-type design suitable for confined spaces such as underground substations, data centers, and ship engine rooms.

  • New Energy and Industrial Applications:Neutral grounding protection for systems including wind/solar power plants, rail transit, mining facilities, and oil platforms.

  • Special Electrical Environments:Compatible with systems containing harmonic pollution, frequent start-stop loads, and smart grids requiring coordination with protection devices.

Solutions - grounding/earthing transformers

  • Services de maintenance intelligents et solutions durables pour les transformateurs de terre de type Z
    Services de maintenance intelligents et solutions durables pour les transformateurs de terre de type ZLes transformateurs de terre de type Z sont essentiels pour stabiliser les systèmes électriques non mis à la terre ou en triangle, en fournissant un chemin d'impédance faible pour les courants de séquence nulle en cas de défaut. L'intégration de pratiques de maintenance intelligentes et durables améliore leur fiabilité tout en minimisant l'impact environnemental. Voici une analyse structurée des

Bibliothèque de ressources documentaires grounding/earthing transformers

Public.
Rockwill Electric Group Profile Rockwill Electric Group Profile
Brochure
English

Questions fréquentes

Le temps de résistance à la faute fait référence au temps maximum qu'un transformateur de terre peut supporter les contraintes thermiques et mécaniques générées par le courant de faute sans subir de dommages sous capacité court-circuit nominale. C'est la base fondamentale pour la conception de l'isolation et de la structure. Les normes IEEE 32 et IEC 60076-5 spécifient quatre types de durées standard : ① 10 secondes : adaptées aux systèmes de protection rapides (comme la protection différentielle à fibre optique), où les fautes peuvent être isolées en moins de 10 secondes ; ② 30 secondes : le niveau de résistance le plus courant, adapté au temps de fonctionnement de la protection relais de la plupart des réseaux de distribution et de transport ; ③ 60 secondes : utilisées pour les systèmes anciens ou les réseaux électriques complexes avec un temps de fonctionnement de protection long ; ④ 1 heure : applicable uniquement aux systèmes de mise à la terre à haute résistance, où le courant de faute est faible mais une surveillance à long terme est nécessaire.

Lors de la sélection, il faut suivre le principe "temps de résistance ≥ temps d'action de la protection + marge de sécurité pour le traitement de la faute". Par exemple, pour un système de 110 kV utilisant une protection surintensité conventionnelle, le temps d'action de la protection est d'environ 15 secondes, et un produit avec un niveau de résistance de 30 secondes doit être sélectionné pour éviter que l'équipement ne brûle en raison d'un temps de résistance insuffisant.

Connaître votre fournisseur

Boutique en ligne
Taux de livraison à temps
Temps de réponse
100.0%
≤4h
Présentation de l'entreprise
Espace de travail: 108000m² Nombre total d'employés: 700+ Exportation Annuelle Maximale (USD): 150000000
Services
Type de business: Conception/Fabrication/Ventes
Catégories principales: transformateur de courant/Postes de transformation préfabriqués et salles électriques préfabriquées/Isolation contre la foudre et protection contre la foudre/appareils électriques à haute tension/Panneaux électriques et dispositifs de commande/transformateur
Demande
+86
Cliquer pour téléverser un fichier
Télécharger
Obtenir l'application commerciale IEE-Business
Utilisez l'application IEE-Business pour trouver du matériel obtenir des solutions se connecter avec des experts et participer à la collaboration sectorielle en tout lieu et à tout moment soutenant pleinement le développement de vos projets et activités dans le secteur de l'énergie
Connexion
ou continuer avec
Nouvel utilisateur ?
S’inscrire