Ania nga tool nagkalkula sa operating voltage sa usa ka electric motor batas sa current, active power, ug power factor.
Ipasulod ang mga parameters sa motor aron ma-automatically calculate:
Operating voltage (V)
Nag-suporta sa single-, two-, ug three-phase systems
Real-time bidirectional calculation
Voltage validation
Calculation sa Voltage:
Single-phase: V = P / (I × PF)
Two-phase: V = P / (√2 × I × PF)
Three-phase: V = P / (√3 × I × PF)
Kung diin:
P: Active power (kW)
I: Current (A)
PF: Power factor (cos φ)
Ejemplo 1:
Three-phase motor, I=10A, P=5.5kW, PF=0.85 →
V = 5.5 / (√3 × 10 × 0.85) ≈ 373.6 V
Ejemplo 2:
Single-phase motor, I=5A, P=0.92kW, PF=0.8 →
V = 0.92 / (5 × 0.8) = 230 V
Ang ipasabot nga data kailangan accurate
Ang voltage dili mahimo mag-negative
Gamiton ang high-precision instruments
Ang voltage mog-agad-agad depende sa load