Description
This tool calculates the starting capacitor value (μF) required for a single-phase induction motor to start properly.
Input motor parameters to automatically calculate:
- Starting capacitor value (μF)
- Supports 50Hz and 60Hz systems
- Real-time bidirectional calculation
- Capacitor validation
Key Formula
Starting Capacitor Calculation:
C_s = (1950 × P) / (V × f)
Where:
C_s: Starting capacitor (μF)
P: Motor power (kW)
V: Voltage (V)
f: Frequency (Hz)
Example Calculations
Example 1:
Motor power=0.5kW, Voltage=230V, Frequency=50Hz →
C_s = (1950 × 0.5) / (230 × 50) ≈ 84.8 μF
Example 2:
Motor power=1.5kW, Voltage=230V, Frequency=50Hz →
C_s = (1950 × 1.5) / (230 × 50) ≈ 254 μF
Important Notes
- Starting capacitor is only used during startup
- Use CBB-type capacitors only
- Must be disconnected after startup
- Voltage and frequency must match