36S1000K-CC Transformer Price Calculator

HZ
$/t
$/t
$/t
$/t
Description

36S1000K-CC oil immersed distribution transformer pricing calculator is a costing budgeting calculator for capacity not exceed than 1000kVA, and rated voltage not exceed 36kV level, full copper winding oil filled distribution transformer price calculation. all design is complied with IEC60076 standard.

Give a tip and encourage the author!
Recommended
Maximum short-circuit current with transformer substation
Maximum short-circuit current with transformer substation
This tool calculates the maximum symmetrical short-circuit current at the output of a transformer substation, based on IEC 60865 and IEEE C37.100 standards. Results are essential for selecting circuit breakers, fuses, busbars, and cables, as well as verifying equipment’s short-circuit withstand capability. Input Parameters Power Net Fault (MVA): Short-circuit power of upstream network, indicating source strength. Higher values lead to higher fault currents. Primary Voltage (kV): Rated voltage on the high-voltage side of the transformer (e.g., 10 kV, 20 kV, 35 kV). Secondary Voltage (V): Rated voltage on the low-voltage side (typically 400 V or 220 V). Transformer Power (kVA): Apparent power rating of the transformer. Voltage Fault (%): Short-circuit impedance percentage (U k %), provided by manufacturer. Key factor in determining fault current. Joule Effect Losses (%): Load loss as a percentage of rated power (P c %), used to estimate equivalent resistance. Medium Voltage Line Length: Length of MV feeder from transformer to load (in m, ft, or yd), affecting line impedance. Line Type: Choose conductor configuration: Overhead line Unipolar cable Multipolar cable Medium Voltage Wire Size: Conductor cross-section, selectable in mm² or AWG, with Copper or Aluminum material options. Medium Voltage Conductors in Parallel: Number of identical conductors connected in parallel; reduces total impedance. Conductor Material: Copper or Aluminum, affecting resistivity. Low Voltage Line Length: Length of LV circuit (m/ft/yd), usually short but significant. Low Voltage Wire Size: Cross-sectional area of LV conductor (mm² or AWG). Low Voltage Conductors in Parallel: Number of parallel conductors on the LV side. Output Results Three-phase short-circuit current (Isc, kA) Single-phase short-circuit current (Isc1, kA) Peak short-circuit current (Ip, kA) Equivalent impedance (Zeq, Ω) Short-circuit power (Ssc, MVA) Reference Standards: IEC 60865, IEEE C37.100 Designed for electrical engineers, power system designers, and safety assessors conducting short-circuit analysis and equipment selection in low-voltage distribution systems.
Related Products
Send inquiry
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.