| Thương hiệu | ROCKWILL |
| Chuỗi | JDS |
Description
As a pioneer and the first dedicated original manufacturer in China's earthing transformer industry, decades of in-depth technical cultivation have enabled us to accumulate strong strength and even establish the original standards for industry development. From breakthroughs in core technology R&D to large-scale mass production and delivery, we have built an end-to-end independent ecosystem. Leveraging leading and stable product performance as well as extremely reliable quality, we have become a trusted choice in the field of power grid construction.
This three - phase 11kV/22kV grounding transformer is tailor - made for medium - voltage power grids. By creating an artificial neutral point, it accurately achieves the grounding protection function and is suitable for various distribution system scenarios. When facing single - phase grounding faults, it can effectively handle them, building a solid defense for the stable operation of urban power grids and industrial power facilities, and ensuring the reliable power supply of the power system.
Main technical parameter
Some of these earthing transformers cover voltage levels including:3.3kV / 6kV / 11kV / 15kV / 20kV / 22kV / 30kV / 33kV / 34.5kV / 36kV / 44kV / 66kV / 88kV / 110kV / 132kV / 145kV / 150kV / 220kV / 275kV / 330kV / 400kV, etc. The current withstand time ranges from 1s, 2s, 3s, 5s, 6s, 8s, 9s, 10s, 30s, 60s, 1hour to 2hours, and customization is available.
Number of phases |
Three rows |
Output voltage |
400V |
Frequency |
50/60Hz |
Input voltage |
11kV 20kV 22kV 30kV 33KV 34.5kV 36kV |
High pressure rating |
11KV/22KV/33KV |
Low pressure rating |
0.4 KV |
Number of coils |
Three Windings |
Link category |
Dyn11 Yyno |
Coil structure |
toroidal |
Certification |
IEC60076 |
Insulation level: |
Dyn11 Yyno |
Application |
Industrial Equipments |
Standard |
IEC60076 |
Use |
Power transformer |
Class |
Oil - Immersed Transformer |
Product name |
Grounding Transformer |
Application Environment Description
Neutral Grounding Systems:Suitable for ungrounded, resistance-grounded, or arc-suppression-coil grounded medium-voltage distribution networks. Limits fault current and improves power supply reliability.
Harsh Physical Environments:IP54/IP56 protection rating, resistant to salt mist and dust. Suitable for altitudes up to 3000m and ambient temperatures from -25°C to +45°C.
Space-Constrained Locations:Compact dry-type design suitable for confined spaces such as underground substations, data centers, and ship engine rooms.
New Energy and Industrial Applications:Neutral grounding protection for systems including wind/solar power plants, rail transit, mining facilities, and oil platforms.
Special Electrical Environments:Compatible with systems containing harmonic pollution, frequent start-stop loads, and smart grids requiring coordination with protection devices.
Thời gian chịu đựng sự cố là thời gian tối đa mà máy biến áp nối đất/đất có thể chịu được các ứng suất nhiệt và cơ học do dòng điện sự cố tạo ra mà không bị hỏng dưới dung lượng ngắn mạch định mức. Đây là cơ sở chính cho thiết kế cách điện và cấu trúc. Tiêu chuẩn IEEE 32 và IEC 60076-5 quy định bốn loại thời gian tiêu chuẩn: ① 10 giây: phù hợp với hệ thống bảo vệ tác động nhanh (như bảo vệ vi sai quang), nơi các sự cố có thể được tách biệt trong vòng 10 giây; ② 30 giây: mức chịu đựng phổ biến nhất, phù hợp với thời gian tác động của bảo vệ rơle của hầu hết các mạng phân phối và hệ thống truyền tải; ③ 60 giây: được sử dụng cho các hệ thống cũ hoặc lưới điện phức tạp có thời gian tác động bảo vệ dài; ④ 1 giờ: chỉ áp dụng cho các hệ thống tiếp đất có điện trở cao, nơi dòng điện sự cố nhỏ nhưng cần theo dõi lâu dài.