| Marca | ROCKWILL |
| Série | JDS |
Description
As a pioneer and the first dedicated original manufacturer in China's earthing transformer industry, decades of in-depth technical cultivation have enabled us to accumulate strong strength and even establish the original standards for industry development. From breakthroughs in core technology R&D to large-scale mass production and delivery, we have built an end-to-end independent ecosystem. Leveraging leading and stable product performance as well as extremely reliable quality, we have become a trusted choice in the field of power grid construction.
This three - phase 11kV/22kV grounding transformer is tailor - made for medium - voltage power grids. By creating an artificial neutral point, it accurately achieves the grounding protection function and is suitable for various distribution system scenarios. When facing single - phase grounding faults, it can effectively handle them, building a solid defense for the stable operation of urban power grids and industrial power facilities, and ensuring the reliable power supply of the power system.
Main technical parameter
Some of these earthing transformers cover voltage levels including:3.3kV / 6kV / 11kV / 15kV / 20kV / 22kV / 30kV / 33kV / 34.5kV / 36kV / 44kV / 66kV / 88kV / 110kV / 132kV / 145kV / 150kV / 220kV / 275kV / 330kV / 400kV, etc. The current withstand time ranges from 1s, 2s, 3s, 5s, 6s, 8s, 9s, 10s, 30s, 60s, 1hour to 2hours, and customization is available.
Number of phases |
Three rows |
Output voltage |
400V |
Frequency |
50/60Hz |
Input voltage |
11kV 20kV 22kV 30kV 33KV 34.5kV 36kV |
High pressure rating |
11KV/22KV/33KV |
Low pressure rating |
0.4 KV |
Number of coils |
Three Windings |
Link category |
Dyn11 Yyno |
Coil structure |
toroidal |
Certification |
IEC60076 |
Insulation level: |
Dyn11 Yyno |
Application |
Industrial Equipments |
Standard |
IEC60076 |
Use |
Power transformer |
Class |
Oil - Immersed Transformer |
Product name |
Grounding Transformer |
Application Environment Description
Neutral Grounding Systems:Suitable for ungrounded, resistance-grounded, or arc-suppression-coil grounded medium-voltage distribution networks. Limits fault current and improves power supply reliability.
Harsh Physical Environments:IP54/IP56 protection rating, resistant to salt mist and dust. Suitable for altitudes up to 3000m and ambient temperatures from -25°C to +45°C.
Space-Constrained Locations:Compact dry-type design suitable for confined spaces such as underground substations, data centers, and ship engine rooms.
New Energy and Industrial Applications:Neutral grounding protection for systems including wind/solar power plants, rail transit, mining facilities, and oil platforms.
Special Electrical Environments:Compatible with systems containing harmonic pollution, frequent start-stop loads, and smart grids requiring coordination with protection devices.
O tempo de resistência a falhas refere-se ao tempo máximo que um transformador de aterramento/ponto de terra pode suportar as tensões térmicas e mecânicas geradas pela corrente de falha sem danos, sob a capacidade de curto-circuito nominal. É a base central para o design de isolamento e estrutural. As normas IEEE 32 e IEC 60076-5 especificam quatro tipos de durações padrão: ① 10 segundos: adequado para sistemas de proteção de ação rápida (como proteção diferencial por fibra óptica), onde as falhas podem ser isoladas em 10 segundos; ② 30 segundos: o nível de resistência mais predominante, adequado para o tempo de ação da proteção relé de maioria das redes de distribuição e sistemas de transmissão; ③ 60 segundos: usado para sistemas antigos ou redes elétricas complexas com tempo longo de ação de proteção; ④ 1 hora: aplicável apenas a sistemas de aterramento de alta resistência, onde a corrente de falha é pequena, mas é necessária uma monitorização a longo prazo.