Transformadores de aterramento/terra de três fases 11kV 22kV

  • Customization Three - phase 11kV 20kV 22kV 30kV grounding/earthing transformers Original Manufacturer
  • Customization Three - phase 11kV 20kV 22kV 30kV grounding/earthing transformers Original Manufacturer

Atributos-chave

Marca ROCKWILL
Série JDS
Descrição

Description

As a pioneer and the first dedicated original manufacturer in China's earthing transformer industry, decades of in-depth technical cultivation have enabled us to accumulate strong strength and even establish the original standards for industry development. From breakthroughs in core technology R&D to large-scale mass production and delivery, we have built an end-to-end independent ecosystem. Leveraging leading and stable product performance as well as extremely reliable quality, we have become a trusted choice in the field of power grid construction.

This three - phase 11kV/22kV grounding transformer is tailor - made for medium - voltage power grids. By creating an artificial neutral point, it accurately achieves the grounding protection function and is suitable for various distribution system scenarios. When facing single - phase grounding faults, it can effectively handle them, building a solid defense for the stable operation of urban power grids and industrial power facilities, and ensuring the reliable power supply of the power system.

Features

  • Flexible Voltage Adaptation: Supports 11kV and 22kV voltage systems, accurately matches the specifications of common medium - voltage power grids, is widely adaptable to diverse power application scenarios, and has strong compatibility.

  • Intelligent Fault Management: When encountering single - phase faults, it quickly suppresses arc - grounding overvoltages, greatly reduces fault currents, reduces the risk of damage to power equipment, and improves the operation and maintenance efficiency of the system.

  • Reliable and Robust Structure: Adopts high - quality iron cores, durable windings, and is matched with a robust shell. It effectively resists the erosion of harsh environments such as moisture and dust, ensures the long - term stable operation of the equipment, and reduces maintenance costs.

  • Comprehensive Safety Assurance: Stably provides neutral point grounding, prevents voltage fluctuations and insulation faults from the source, safeguards the safety of the power grid and associated electrical equipment, and builds a solid foundation for the safety of the power system.

Main technical parameter

Some of these earthing transformers cover voltage levels including:3.3kV / 6kV / 11kV / 15kV / 20kV / 22kV / 30kV / 33kV / 34.5kV / 36kV / 44kV / 66kV / 88kV / 110kV / 132kV / 145kV / 150kV / 220kV / 275kV / 330kV / 400kV, etc. The current withstand time ranges from 1s, 2s, 3s, 5s, 6s, 8s, 9s, 10s, 30s, 60s, 1hour to 2hours, and customization is available.

Number of phases

Three rows

Output voltage

400V

Frequency

50/60Hz

Input voltage

11kV  20kV 22kV 30kV 33KV 34.5kV 36kV

High pressure rating

11KV/22KV/33KV

Low pressure rating

0.4 KV

Number of coils

Three Windings

Link category

Dyn11 Yyno

Coil structure

toroidal

Certification

IEC60076

Insulation level:

Dyn11 Yyno

Application

Industrial Equipments

Standard

IEC60076

Use

Power transformer

Class

Oil - Immersed Transformer

Product name

Grounding Transformer

Application Environment Description

  • Neutral Grounding Systems:Suitable for ungrounded, resistance-grounded, or arc-suppression-coil grounded medium-voltage distribution networks. Limits fault current and improves power supply reliability.

  • Harsh Physical Environments:IP54/IP56 protection rating, resistant to salt mist and dust. Suitable for altitudes up to 3000m and ambient temperatures from -25°C to +45°C.

  • Space-Constrained Locations:Compact dry-type design suitable for confined spaces such as underground substations, data centers, and ship engine rooms.

  • New Energy and Industrial Applications:Neutral grounding protection for systems including wind/solar power plants, rail transit, mining facilities, and oil platforms.

  • Special Electrical Environments:Compatible with systems containing harmonic pollution, frequent start-stop loads, and smart grids requiring coordination with protection devices.

Soluções - grounding/earthing transformers

  • Serviços de Manutenção Inteligentes e Soluções Sustentáveis para Transformadores de Aterramento do Tipo Z
    Serviços de Manutenção Inteligente e Soluções Sustentáveis para Transformadores de Aterramento do Tipo ZOs transformadores de aterramento do tipo Z são críticos para estabilizar sistemas de energia não aterrados ou conectados em delta, fornecendo um caminho de baixa impedância para correntes de sequência zero durante falhas. Integrar práticas de manutenção inteligente e sustentabilidade aumenta a confiabilidade, enquanto minimiza o impacto ambiental. Abaixo está uma análise estruturada de soluçõ

Biblioteca de Recursos de Documentação grounding/earthing transformers

Public.
Rockwill Electric Group Profile Rockwill Electric Group Profile
Brochure
English

Perguntas Frequentes

O tempo de resistência a falhas refere-se ao tempo máximo que um transformador de aterramento/ponto de terra pode suportar as tensões térmicas e mecânicas geradas pela corrente de falha sem danos, sob a capacidade de curto-circuito nominal. É a base central para o design de isolamento e estrutural. As normas IEEE 32 e IEC 60076-5 especificam quatro tipos de durações padrão: ① 10 segundos: adequado para sistemas de proteção de ação rápida (como proteção diferencial por fibra óptica), onde as falhas podem ser isoladas em 10 segundos; ② 30 segundos: o nível de resistência mais predominante, adequado para o tempo de ação da proteção relé de maioria das redes de distribuição e sistemas de transmissão; ③ 60 segundos: usado para sistemas antigos ou redes elétricas complexas com tempo longo de ação de proteção; ④ 1 hora: aplicável apenas a sistemas de aterramento de alta resistência, onde a corrente de falha é pequena, mas é necessária uma monitorização a longo prazo.

Durante a seleção, deve-se seguir o princípio de "tempo de resistência ≥ tempo de ação da proteção + redundância no tratamento de falhas". Por exemplo, para um sistema de 110kV utilizando proteção de sobrecorrente convencional, o tempo de ação da proteção é de cerca de 15 segundos, e deve-se selecionar um produto com nível de resistência de 30 segundos para evitar queimaduras no equipamento devido a tempo de resistência insuficiente.

Conheça seu fornecedor

Loja online
Taxa de entrega no prazo
Tempo de resposta
100.0%
≤4h
Visão geral da empresa
Local de Trabalho: 108000m² Número total de funcionários: 700+ Maior Valor de Exportação Anual (USD): 150000000
Serviços
Tipo de Negócio: Design/Fabricação/Vendas
Categorias Principais: Transformador/Subestação compacta e sala elétrica pré-fabricada/Isolamento contra raios e proteção contra descargas atmosféricas/aparelhos de alta tensão/Painéis elétricos e dispositivos de controle/transformador