Recloser a vácuo de alta tensão para exterior 27kV

  • Customization 27kV 33kV 33.5kV 34.5kV 35kV Outdoor High - Voltage Vacuum Three-phase recloser/reclosure

Atributos-chave

Marca ROCKWILL
Série RCW
Descrição

Description:

Pioneer in China’s recloser industry and the first source manufacturer dedicated to this field — this is our identity forged by decades of deep cultivation. Over the past decades, we have consolidated our development foundation through technological breakthroughs, led the industry direction by formulating standards, and successfully built a fully independent system covering core technology R&D, large-scale mass production and delivery.

The RCW series automatic circuit reclosers are designed for use in overhead distribution lines and distribution substations. They are compatible with power systems operating at 50/60Hz, covering voltage classes from 11kV to 38kV. With a rated current capacity of up to 1250A, these reclosers integrate multiple functions, including control, protection, measurement, communication, fault detection, and real - time monitoring of closing and opening operations. Composed of an integration terminal, current transformer, permanent magnetic actuator, and a dedicated recloser controller, the RCW series vacuum reclosers offer a comprehensive solution for power distribution network management.

Features:

  • Flexible Current Ratings: Optional ratings within the rated current range to suit diverse application needs.

  • Customizable Protection: A variety of optional relay protection and logic schemes for users to choose from, ensuring adaptability to different system requirements.

  • Versatile Communication: Optional communication protocols and I/O ports available, enabling seamless integration with various monitoring and control systems.

  • User - Friendly Software: Equipped with PC software that supports controller testing, setup, programming, and updates, simplifying operation and maintenance.

Parameters:

The voltage classes of some of these Automatic Reclosers include 6kV, 6.3kV, 6.6kV, 6.9kV, 7.2kV, 10kV, 10.5kV, 11kV, 11.5kV, 12kV, 13.2kV, 13.8kV, 14.5kV, 14.4kV, 15kV, 15.5kV, 15.6kV, 17.5kV, 20kV, 21.9kV, 22kV, 24kV, 30kV, 33kV, 33.5kV, 34.5kV, 35kV, 36kV, 38kV, 38.5kV, 40.5kV, 44kV, 45kV, 46kV, 66kV and 69kV. Rated Short-Circuit Breaking Current includes 8kA, 12.5kA, 16kA, 20kA, 25kA, 31.5kA and customization is available.

Item

Specification

Rated maximum voltage

27kV

Rated maximum current

1250A

Rated frequency

50Hz

Rated short circuit breaking current

12.5kA

Rated peak value withstand current

31.5kA

Rated 1min power frequency withstand voltage (Three-phase Silicone rubber pole (unable the gas))

70kV

Rated lightning impulse voltage (Three-phase Silicone rubber pole (unable the gas))

150kV

Operation sequence

C-0.5-CO-2-CO-5-CO (Magnetic actuator)

Mechanical life

n:30000 (Magnetic actuator)

Power supply and operating voltage

110/220V (Customized)

Ratio of current transformer

400/1A (Customized)

Number of voltage sensors (Three-phase Silicone rubber pole (unable the gas))

≤3

Opening time

≤30ms (Magnetic actuator)

Closing time

≤40ms (Magnetic actuator)

Minimum creepage distance

31, level4 (mm/kV)

Minimum distance between phases

380mm

Potential transformer

110/220V (Customized)

Cable length

6,8,12m (Customized)

Cable clamp (Three-phase Silicone rubber pole (unable the gas))

2-hole NEMA

Lightning arrester

≤6

Mounting type

Single / double column

With optional relay protection & logics for user choice

Instantaneous over-current protection

Timing over-current protection

Negative sequence over-current protection

Directional over-current protection(⁽¹⁾)

Over-voltage protection / Under voltage protection

Programmable protection relay curves (total 10 nos ANSI/IEC curves)

Cold load pickup protection TCC + Hot line tag

Earth protection E/F SEF + Zone- Sequence Co-ordination

More relay functions can be customized

With optional communication protocols & I/O port for user choice

RS-232 and RS-485 ports supporting

DNP3.0 communication protocol support

Modbus communication protocol is optional

IEC 60870-501 communication protocol support

IEC 60870-5-104 communication protocol support

The recloser can communicate through GPRS(or) GSM(or) GPRS/GSM module with English or Specified language

With optional functions for use

Rated currents, System phase current,

Rated voltages, System phase voltage and secondary low voltage power supply voltage Frequency

power (kWh), reactive power (kVarh), power factor

With optional reclosing interval for user pre-program

reclosing times setting support

Dead time setting support

With events recording function

SOE 10000 operations record

Fault record and normal operation record

Note:mean should customized by manufacturer if needed

External dimensions:

企业微信截图_17103058136732.png

Environmental requirement:

Maximum temperature:

+40°C

Minimum temperature:

-30°C

Monthly average humidity

95%

Humidity:

90%

Above sea level:

2500m or higher

Ambient air Not apparently polluted by corrosive and flammable gas, vapor


 What are the key points for the selection of outdoor vacuum reclosers?

  • System Parameter Matching: Choose a recloser that matches the rated voltage, rated current, and short-circuit current levels of the power system. Ensure that the rated voltage of the recloser is equal to or higher than the system voltage, the rated current meets the requirements of the line load current, and the rated short-circuit breaking and making currents are greater than the maximum possible short-circuit current in the system.

  • Reclosing Performance Requirements: Consider the specific requirements of the power system for the reclosing function, such as the number of reclosures, reclosing time intervals, and reclosing success rate. Based on different application scenarios and power supply reliability requirements, select a recloser with appropriate reclosing performance. For example, for critical power supply lines, a recloser with a higher number of reclosures and flexible reclosing time intervals may be required.

  • Type of Operating Mechanism: Choose an appropriate operating mechanism based on actual needs. Spring-operated mechanisms are suitable for outdoor environments where high reliability is required and maintenance conditions are relatively poor. Permanent magnet-operated mechanisms are better suited for applications requiring high action speed and frequent operations.

  • Environmental Adaptability: Given the harsh conditions of outdoor environments, consider the environmental adaptability of the recloser. This includes weather resistance, pollution resistance, and water and dustproof performance. Selecting a recloser with good environmental adaptability ensures stable performance during long-term outdoor operation.

  • Brand and Quality: Choose well-known brands and high-quality recloser products. These products have strict quality control systems in design, manufacturing, and testing, ensuring the performance and reliability of the product. Additionally, good after-sales service is an important factor to consider when choosing a brand, as it ensures timely resolution of issues that may arise during equipment operation.


Biblioteca de Recursos de Documentação Vacuum recloser

Public.
27kV automatic recloser technology specification
Technical Data
English
Restricted
10 to 38kV auto vacuum break recloser Catalog
Catalogue
English
Consulting
Restricted
15kV/27kV/38kV outdoor auto break vacuum recloser brochure
Brochure
English
Consulting
Restricted
Specification for 33kV Vacuum Automatic Recloser by Kenya Power and Lighting Company Limited (KPLC)
Others
English
Consulting
Restricted
SEC SPECIFICATIONS FOR SMART MV AUTO-RECLOSER
Others
English
Consulting
Public.
DEKRA Recloser Test Report
Test Report
English
Public.
RCW-E38M/1250-20 MV Outdoor Vacuum Recloser
Drawings
English

Perguntas Frequentes para Vacuum recloser

Q: A Rockwill oferece uma alternativa custo-efetiva que é mais econômica do que a série RCW+ padrão?
A:

Sim. A configuração RCWP oferece uma opção otimizada em termos de custo dentro da família RCW+. Inclui sensores duplos (tensão + corrente), controlador topo de linha e 30.000 operações mecânicas com mecanismo de operação de ímã permanente acionando acoplamento trifásico.

Para alcançar um ponto de preço mais acessível, as seguintes opções de downgrade estão disponíveis:

  • Remover caixa de bloqueio de ímã permanente
  • Remover função de bloqueio
  • Rebaixar especificação do sensor de tensão
  • Rebaixar especificação do controlador (por exemplo, de topo de linha para padrão)

Isso permite que os clientes comecem com uma plataforma base compatível e confiável, pagando apenas pelos recursos de que realmente precisam.

Q: A Rockwill realmente oferece uma garantia de qualidade de 10 anos e substituição gratuita?
A:

Sim. A Rockwill apoia a série RCW com uma das garantias mais abrangentes da indústria de religadores:

  • Garantia de 10 anos cobrindo o religador completo, incluindo o interrompedor a vácuo, o mecanismo operacional de ímã permanente e a eletrônica de controle
  • Substituição gratuita para qualquer falha resultante de defeitos de material ou fabricação durante o período de garantia
  • Sem condições ocultas — termos de garantia diretos sem exclusões complexas
 
Q: Quais são as principais diferenças entre o religador da série RCW da Rockwill e um disjuntor a vácuo do tipo ZW32
A:
  • Objetivo de Design: Recloser projetado com lógica de religamento automático — o VCB do tipo ZW32 é um disjuntor básico ou chave de demarcação
  • Material: Borracha de silicone / Epoxy (superioridade em envelhecimento e absorção de água) — moldado DMC/SMC (maior absorção de água, envelhecimento mais rápido)
  • Lógica de Proteção: Controle completo do recloser com curvas de proteção configuráveis — lógica de recloser limitada ou inexistente
  • Compatibilidade com a Rede: Projetado com controle integrado de recloser, sensores e comunicação para automação de distribuição internacional (IEC 62271-111 / ANSI C37.60) — VCB autônomo que requer controlador externo para automação; projetado principalmente para proteção básica
  • Relatórios de Teste: Relatórios completos de teste de tipo disponíveis — varia de acordo com o fabricante

Resumo: Um VCB do tipo ZW32 não pode ser substituído diretamente por um recloser na maioria das aplicações de automação de distribuição internacional. A série RCW fornece a lógica de proteção, integração de sensores e inteligência de controle necessárias para a implementação de redes inteligentes modernas.

Conheça seu fornecedor

Loja online
Taxa de entrega no prazo
Tempo de resposta
100.0%
≤4h
Visão geral da empresa
Local de Trabalho: 108000m² Número total de funcionários: 700+ Maior Valor de Exportação Anual (USD): 150000000
Serviços
Tipo de Negócio: Design/Fabricação/Vendas
Categorias Principais: aparelhos de alta tensão/transformador
Produtos Relacionados
Conhecimentos Relacionados
  • Religadores a vácuo Rockwill RCW: quais são as vantagens de sua coordenação de proteção em quatro etapas?
    O "mecanismo de coordenação de proteção em quatro etapas" — tipicamente uma sequência de quatro operações combinadas com curvas tempo-corrente rápidas/lentas — é o núcleo da automação de distribuição e da auto-recuperação de falhas em linhas aéreas.Esta coordenação em quatro etapas (por exemplo, padrões de disparo "1 rápido + 3 lentos" ou "2 rápidos + 2 lentos") aplicada nos religadores a vácuo da série RCW oferece as seguintes vantagens significativas:1. Implementação Perfeita da Es
    07/01/2026
Enviar consulta
+86
Clique para fazer upload do arquivo
Baixar
Obter Aplicativo Comercial IEE-Business
Use o aplicativo IEE-Business para encontrar equipamentos obter soluções conectar-se com especialistas e participar da colaboração setorial em qualquer lugar e a qualquer hora apoiando totalmente o desenvolvimento de seus projetos e negócios no setor de energia
Login
ou continuar com
Novo aqui?
Registrar