| Brand | ROCKWILL |
| Model NO. | Single Phase Automatic Voltage Regulator 7.62 kV 13.8 kV 19.92 kV 34.5 kV |
| Rated voltage | 34.5kV |
| Rated normal current | 100A |
| Rated frequency | 50/60Hz |
| Series | RVR-1 |
|
Voltage (kV) |
Current (A) |
Capacity (kVA) |
BIL (kV) |
Power Frequency Withstand Voltage (kV) |
Insulation Class |
|
6/6.35 |
50 |
30/32 |
75/95 |
28 |
A |
|
100 |
60/64 |
||||
|
150 |
90/95 |
||||
|
200 |
120/127 |
||||
|
300 |
180/191 |
||||
|
400 |
240/254 |
||||
|
500 |
300/318 |
||||
|
600 |
360/381 |
||||
|
11 |
50 |
55 |
|||
|
100 |
110 |
||||
|
150 |
165 |
||||
|
200 |
220 |
||||
|
300 |
330 |
||||
|
400 |
440 |
||||
|
500 |
550 |
||||
|
600 |
660 |
||||
|
15 |
50 |
75 |
125/150 |
50 |
|
|
100 |
150 |
||||
|
150 |
225 |
||||
|
200 |
300 |
||||
|
300 |
450 |
||||
|
400 |
600 |
||||
|
500 |
750 |
||||
|
22 |
50 |
110 |
|||
|
100 |
220 |
||||
|
150 |
330 |
||||
|
200 |
440 |
||||
|
300 |
660 |
||||
|
33 |
50 |
165 |
170/200 |
70 |
|
|
100 |
330 |
||||
|
150 |
495 |
||||
|
200 |
660 |
||||
|
250 |
825 |
||||
|
300 |
990 |
|
Voltage (kV) |
Current (A) |
Capacity (kVA) |
BIL (kV) |
Power Frequency Withstand Voltage (kV) |
Insulation Class |
|
7.62 |
50 |
38 |
60/75 |
20 |
A |
|
100 |
76 |
||||
|
150 |
114 |
||||
|
219 |
167 |
||||
|
328 |
250 |
||||
|
438 |
333 |
||||
|
546 |
416 |
||||
|
13.8 |
50 |
69 |
95/125 |
38 |
|
|
100 |
138 |
||||
|
150 |
207 |
||||
|
200 |
276 |
||||
|
300 |
414 |
||||
|
400 |
552 |
||||
|
14.4 |
50 |
72 |
|||
|
100 |
144 |
||||
|
200 |
288 |
||||
|
300 |
432 |
||||
|
400 |
576 |
||||
|
19.92 |
50 |
100 |
170/200 |
70 |
|
|
100 |
200 |
||||
|
167 |
333 |
||||
|
200 |
400 |
||||
|
335 |
667 |
||||
|
34.5 |
50 |
165 |
|||
|
100 |
330 |
||||
|
150 |
495 |
||||
|
200 |
660 |
Reference Photo

1.Stability: Strictly designed in compliance with IEC 60076 standards, equipped with an intelligent closed-loop control and precise step voltage regulation mechanism. It real-time monitors voltage fluctuations and performs automatic fine-tuning. Core components are verified through type tests to ensure a voltage error of ≤±1%.
2.Safety: Built-in overvoltage/overcurrent/overtemperature protection, insulation protection, and arc-extinguishing design for tap changers. The entire process complies with IEC 60076 safety specifications, and it supports automatic shutdown in case of faults to eliminate operational risks.
Yes, we offer flexible OEM customization. We can tailor key parameters such as voltage (6 kV~34.5 kV), capacity, and control functions according to customers' specific power system requirements, while ensuring full compliance with IEC 60076 standards.