• JDZXW-36W2 Outdoor Voltage Transformer
JDZXW-36W2 Outdoor Voltage Transformer
discuss personally
Model
JDZXW-36W2
Basic info
Brand Wone Store
Model NO. JDZXW-36W2 Outdoor Voltage Transformer
Rated frequency 50/60Hz
Primary voltage 35/√3kV
Secondary voltage 110/√3V
Series JDZXW
Product Detail

Product Overview

JDZXW-36W2 voltage transformer adopts outdoor epoxy resin material casting and single pole insulated voltage transformer, is widely used for measuring current, electric energy and protective relaying in the electric system with the frequency 50Hz or 60Hz and highest voltage for equipment 36 kV (Up to ~40.5kV).

The iron core adopts advanced cold-rolled silicon steel sheet. High voltage outgoing line of primary winding was fetched out from top of the product; outgoing line of secondary winding was fetched out from transverse side of the product.

Key Features

  • Outdoor Protection Design:Adopts silicone rubber composite insulation jacket with IP67 protection rating, resisting salt fog, dust, UV radiation, and other harsh environmental factors to ensure long-term outdoor operational stability. The external insulation creepage distance ≥31mm/kV, suitable for Class Ⅲ and above pollution areas, effectively reducing the risk of fouling flashover accidents.

  • High-precision Voltage Conversion:Utilizes high-quality silicon steel core and optimized electromagnetic design, with voltage ratio error controlled within Class 0.2 and phase difference ≤10', providing precise voltage signals for metering devices and relay protection systems to meet high-precision measurement requirements of power systems.

  • Wide Temperature Adaptability:Operates within the temperature range of -40℃~+70℃, using low-temperature tough epoxy resin and high-temperature resistant insulation materials to ensure stable performance in extreme temperature environments and avoid insulation aging caused by temperature changes.

  • High Insulation Reliability:The insulation system passes 36kV/75kV/170kV withstand voltage tests with partial discharge ≤5pC, and is equipped with built-in overvoltage protection devices to effectively prevent damage from switching overvoltage and lightning impulse.

Main technical parameter

  • Rated primary voltage:30/√3kV or 33/√3kV or 34.5/√3kV or 35/√3kV etc

  • Rated secondary voltage:100/√3V or 110/√3V or 115/√3V or 120/√3V

  • Rated voltage of residual voltage windings:100/ 3V or 110/ 3V or 115/ 3V or 120/ 3V

  • Technical standard accords with IEC 60044-2.2003 or IEEE etc

Other parameters pls see as follow:

Remarks: Upon request we are glad to offer transformers according to other standards or with non-standard technical specs.

Know your supplier
Wone Store
Main Categories
High voltage/Low voltage/Wire cable/Instrument meters/New energy/Tester/Production equipment/Generator/Electrical fittings/Integrated Electrical Equipment/Instrument Transformer/Equipment Parts
Business Type
Sales
Highest Annual Export (USD)
$300000000
Professional Experience
1 years
Workplace
1000m²
占位
占位
Related Products
Related Knowledges
Analysis of Partial Discharge Principle (1)
Analysis of Partial Discharge Principle (1)
Analysis of Partial Discharge Principle (1)Under the action of an electric field, in an insulation system, discharge occurs only in some regions and does not penetrate between the conductors with the applied voltage. This phenomenon is called partial discharge. If partial discharge occurs near a conductor surrounded by gas, it can also be called corona.Partial discharge can occur not only at the edge of a conductor but also on the surface or inside an insulator. The discharge occurring on the su
Leon
07/19/2025
What types of FACTS controllers are there?
What types of FACTS controllers are there?
According to the type of connection FACTS Controller with the power system, it is classified as;Series Connected ControllerShunt Connected ControllerCombined Series-Series ControllerCombined Shunt-Series ControllerSeries-Connected ControllersSeries controllers introduce a voltage in series with the line voltage, typically using capacitive or inductive impedance devices. Their primary function is to supply or absorb variable reactive power as needed.When a transmission line is heavily loaded, the
Edwiin
07/19/2025
What are FACTS and related technologies?
What are FACTS and related technologies?
FACTS (Flexible Alternating Current Transmission System) refers to a power electronics-based system that uses static devices to enhance the power transfer capability and controllability of AC transmission networks.These power electronic devices are integrated into conventional AC grids to boost key performance metrics, including:Power transfer capacity of transmission linesVoltage stability and transient stabilityVoltage regulation precisionSystem reliabilityThermal limits of transmission infras
Edwiin
07/19/2025
What are the differences between HVAC and HVDC?
What are the differences between HVAC and HVDC?
Difference Between HVAC and HVDCElectricity generated in power plants is transmitted over long distances to electrical substations, which then distribute it to consumers. The voltage used for long-distance power transmission is extremely high, and we will explore the reasons for this high voltage later. Additionally, the transmitted power can be in either alternating current (AC) or direct current (DC) form. Therefore, power can be transmitted using either HVAC (High Voltage Alternating Current)
Edwiin
07/19/2025
What are the Advantages of HVDC over HVAC?
What are the Advantages of HVDC over HVAC?
What are the Advantages of HVDC over HVAC?Electricity travels long distances before reaching consumers. Power plants, often remote, supply electricity through hundreds of miles and multiple substations. High-voltage transmission reduces line losses, with both AC and DC used. Though AC is familiar via utility poles and home outlets, HVDC offers unique advantages in power transmission.The goal of power transmission is to minimize losses and costs. While both face influencing factors, HVDC has more
Edwiin
07/19/2025
Is the neutral - point grounding method of the power grid of 110kV and above only the neutral - point direct grounding method?
Is the neutral - point grounding method of the power grid of 110kV and above only the neutral - point direct grounding method?
Neutral - Point Grounding Modes and Protection of Transformers in Power GridsFor systems ranging from 110 kV to 500 kV, an effective grounding method shall be adopted. Specifically, under all operating conditions, the ratio of zero - sequence reactance to positive - sequence reactance X0/X1 of the system should be a positive value and not exceed 3. Meanwhile, the ratio of zero - sequence resistance to positive - sequence reactance R0/X1should also be a positive value and not exceed 1.In 330 kV a