• JZW-72.5 Outdoor Voltage Transformer
JZW-72.5 Outdoor Voltage Transformer
discuss personally
Model
JZW-72.5
Basic info
Brand Wone Store
Model NO. JZW-72.5 Outdoor Voltage Transformer
Rated frequency 50/60Hz
Primary voltage 66/√3kV
Secondary voltage 110/√3V
Series JZW
Product Detail

Product Overview

JZW-72.5 voltage transformer, epoxy resin casting and outdoor installation, is widely used for measuring current, electric energy and protective relaying in the power system with the frequency of 50Hz or 60 Hz and rated voltage of 66kV or 69kV.

The product can be operated on many circumstances such as the areas of altiplano, tropical area, chillness, coastland and dirtiness etc.

Key Features

  • High Voltage Rating Adaptability:With a rated voltage of 72.5kV, it is specially designed for medium-to-high voltage outdoor substations, enabling precise system voltage measurement to meet metering, protection, and monitoring needs of grids up to 72.5kV.

  • Fully Sealed Weather-resistant Structure:Featuring silicone rubber composite insulators and a stainless steel housing, it achieves IP67 protection rating, offering excellent moisture, dust, and salt fog resistance. It withstands strong UV radiation and extreme temperatures from -40℃ to +70℃, adapting to harsh outdoor environments like deserts and coastal areas.

  • Anti-fouling Flashover & Explosion-proof Design:With external insulation creepage distance ≥35mm/kV, anti-fouling flashover skirts, and a hydrophobic coating, it suits Class Ⅳ pollution areas. Certified to IEC 60076-11 explosion-proof standards, it integrates a pressure relief device to ensure no explosion risk during faults.

  • High-precision Voltage Transformation:Utilizing low-loss silicon steel sheets and foil winding technology, it maintains voltage ratio error ≤0.2% and phase difference ≤10', meeting 0.2-class metering accuracy requirements to provide precise voltage data for power grids.

  • Low Power Consumption & Long Lifespan:With no-load loss ≤60VA and load loss ≤150VA, it saves 15% energy compared to traditional transformers. The epoxy resin casting insulation system ensures a 40-year service life, reducing replacement frequency and O&M costs.

Main technical parameter

  • Highest voltage for equipment: 72.5kV

  • Rated primary voltage: 66/√3kV or 69/√3kV etc

  • Limiting output :2000VA

  • Rated power-frequency withstand voltage: 140kV

  • Rated lightning impulse withstand voltage: 325kV or 350kV

  • Rated insulation level: 72.5/140/325kV or  72.5/140/350 kV

  • Technical standard accords with IEC 60044-2:2003 Part2 Instrument transformers-Part2: inductive voltage transformers or IEEE STD C57.13-2008

Remarks: Upon request we are glad to offer transformers according to other standards or with non-standard technical specs.

 

Know your supplier
Wone Store
Main Categories
High voltage/Low voltage/Wire cable/Instrument meters/New energy/Tester/Production equipment/Generator/Electrical fittings/Integrated Electrical Equipment/Instrument Transformer/Equipment Parts
Business Type
Sales
Highest Annual Export (USD)
$300000000
Professional Experience
1 years
Workplace
1000m²
占位
占位
Related Products
Related Knowledges
Analysis of Partial Discharge Principle (1)
Analysis of Partial Discharge Principle (1)
Analysis of Partial Discharge Principle (1)Under the action of an electric field, in an insulation system, discharge occurs only in some regions and does not penetrate between the conductors with the applied voltage. This phenomenon is called partial discharge. If partial discharge occurs near a conductor surrounded by gas, it can also be called corona.Partial discharge can occur not only at the edge of a conductor but also on the surface or inside an insulator. The discharge occurring on the su
Leon
07/19/2025
What types of FACTS controllers are there?
What types of FACTS controllers are there?
According to the type of connection FACTS Controller with the power system, it is classified as;Series Connected ControllerShunt Connected ControllerCombined Series-Series ControllerCombined Shunt-Series ControllerSeries-Connected ControllersSeries controllers introduce a voltage in series with the line voltage, typically using capacitive or inductive impedance devices. Their primary function is to supply or absorb variable reactive power as needed.When a transmission line is heavily loaded, the
Edwiin
07/19/2025
What are FACTS and related technologies?
What are FACTS and related technologies?
FACTS (Flexible Alternating Current Transmission System) refers to a power electronics-based system that uses static devices to enhance the power transfer capability and controllability of AC transmission networks.These power electronic devices are integrated into conventional AC grids to boost key performance metrics, including:Power transfer capacity of transmission linesVoltage stability and transient stabilityVoltage regulation precisionSystem reliabilityThermal limits of transmission infras
Edwiin
07/19/2025
What are the differences between HVAC and HVDC?
What are the differences between HVAC and HVDC?
Difference Between HVAC and HVDCElectricity generated in power plants is transmitted over long distances to electrical substations, which then distribute it to consumers. The voltage used for long-distance power transmission is extremely high, and we will explore the reasons for this high voltage later. Additionally, the transmitted power can be in either alternating current (AC) or direct current (DC) form. Therefore, power can be transmitted using either HVAC (High Voltage Alternating Current)
Edwiin
07/19/2025
What are the Advantages of HVDC over HVAC?
What are the Advantages of HVDC over HVAC?
What are the Advantages of HVDC over HVAC?Electricity travels long distances before reaching consumers. Power plants, often remote, supply electricity through hundreds of miles and multiple substations. High-voltage transmission reduces line losses, with both AC and DC used. Though AC is familiar via utility poles and home outlets, HVDC offers unique advantages in power transmission.The goal of power transmission is to minimize losses and costs. While both face influencing factors, HVDC has more
Edwiin
07/19/2025
Is the neutral - point grounding method of the power grid of 110kV and above only the neutral - point direct grounding method?
Is the neutral - point grounding method of the power grid of 110kV and above only the neutral - point direct grounding method?
Neutral - Point Grounding Modes and Protection of Transformers in Power GridsFor systems ranging from 110 kV to 500 kV, an effective grounding method shall be adopted. Specifically, under all operating conditions, the ratio of zero - sequence reactance to positive - sequence reactance X0/X1 of the system should be a positive value and not exceed 3. Meanwhile, the ratio of zero - sequence resistance to positive - sequence reactance R0/X1should also be a positive value and not exceed 1.In 330 kV a
Leon
07/19/2025
×
Inquiry
Download