Dispositivum Intelligentis Ad Arcus Supprimendum (pro Systematibus 3–35 kV Non-Connexis)

  •  Intelligent Arc Suppression Device (for 3–35 kV Ungrounded Systems)
  •  Intelligent Arc Suppression Device (for 3–35 kV Ungrounded Systems)
  •  Intelligent Arc Suppression Device (for 3–35 kV Ungrounded Systems)

Attributa principalia

Marca Rw Energy
Numerus Modeli Dispositivum Intelligentis Ad Arcus Supprimendum (pro Systematibus 3–35 kV Non-Connexis)
Votum nominatum 35kV
Frequenta nominata 50Hz
Series RMRXHG

Descriptiones productorum a fornitori

Descriptio

In retebus electricitatis Sinensium, quae operantur in tensionibus 3–35 kV, pleraque systemata cum neutro non connecto operantur. Normae permittunt operationem post defectum uniphasicum ad terram usque ad duas horas, quod minuit costus operationis et augit fiduciam suppeditationis. Tamen, cum capacitas systematis crescat et lineae aereae progressim per lineas catenarias substituantur, currentus capacitivus systematis ad terram significanter augebitur.
Cum defectus uniphasicus ad terram evenit, magnus currentus capacitivus facit ut arcus defectus difficilis sit extinguendus, quod evadere potest in arcus intermittentes. Resultantes supra-tensiones arcus ad terram et supra-tensiones ferroresonantiae gravia pericula ad securitatem retei praebent. Inter haec, supra-tensio arcus uniphasici ad terram est maxime critica—phasae non defectuosae potest crescere ad 3–3.5× suam normalem tensionem phasalem. Expositio continua huiusmodi nivei damnum apparatus insulatorii efficiet; degradatio cumulativa loca debilitat, quae ad fracturam insulatorii ad terram, defectus interphasales, defectus insulatorii motorum, explosiones catenarum, saturatio PT et ferroresonantia causante combustionem PT, et explosiones protectorum ducit.

Traditione, in retebus bobines suppressionis arcuum ad neutrum installantur ut currentum capacitivum compensent et probabilitatem arcuum reducant. Tamen propter limites inhaerentes bobinorum suppressionis arcuum—praesertim difficultatem efficaciter currentum (notabiliter componentes altae frequentiae) quae apparatus nocent compensandi—mitigatio saepe est insufficiens.
Ex studio extenso talium bobinorum, RMRXHG Apparatum Intelligentem Suppressionis Arcuum edidimus, qui ad supprimendum et protegendum systemata non connecta contra supra-tensiones longaevi ex defectibus arcus ad terram designatus est.

Ambitus Applicationis

  • Applicabile ad systemata mediae tensionis 3–35 kV.
  • Adaptatum ad systemata neutra non connecta, systemata resonans connecta (per bobinum suppressionis arcuum), et systemata alta resistencia connecta.
  • Adaptatum ad rete dominatum a lineis catenariis, mixta lineis catenariis et aereis, vel rete dominatum a lineis aereis.

Functiones Fundamentales

  • Durante operatione normali, apparatum signala PT monitorat et functiones alarmis, trip, et lockout systematis praebet. Includit detectionem defectus uniphasici ad terram, locationem puncti transitus defectus, suppressionem arcuum, suppressionem harmonicorum, alarmum supra-tensionis, et functiones registrationis defectus.
  • Registra parametra sicut tempus defectus, typus defectus, phasam defectus, tensionem lineam, et currentem neutrum, facilitans analysis defectus.
  • Cum defectus uniphasicus ad terram evenit, apparatum respondet intra 30 ms, determinat typum defectus, et automatica electionem suppressionis arcuum (bobinus suppressionis arcuum, resistens ad terram, vel alia methoda) facit.
  • Supprimit arcus ad terram continuos, minuens periculum fracturae insulatorii, defectus interphasales, vel explosiones apparatus.
  • Praebet monitoring disconnectionis PT, praeventans actiones falsas ex defectibus PT.
  • Habet technologiam commutationis PTK intelligentis, quae supra-tensiones continuas ex defectibus arcus ad terram suppressit, tutando securitatem apparatus.
  • Supportat communicationem RS-485 et protocolum MODBUS pro acquisitione datarum et monitoring remotus.

Functiones Additionales

  • Configurari potest cum circuitu selectionis neutri automatico.
  • Operatur cum apparatu RMRXL selectionis defectus parvi currentis ad accuratiam detectionis defectus meliorandam.
  • Modus "eliminatio" optionalis: technologia specialis dischargit residuum charge et praeventat damnum ferroresonantiae PTs.
  • Moduli suppressionis harmonicorum additionales customizabiles ab usuariis disponibiles sunt.

Principium Operationis

  • Controller continuo voltages secundarias PTs in connectione open-delta monitorat.
  • Cum defectus uniphasicus ad terram evenit, mutationes in voltages secundaris PT (Ua, Ub, Uc) analysantur ad typum defectus determinandum.
  • Pro defectibus metallicis ad terram, apparatum cito isolat punctum defectus, emittit signala trip, et tuto apparatus et personale protegit.
  • Pro defectibus arcus ad terram intermittenti, systema characteristica defectus detexit et unitatem suppressionis intra 30–40 ms automatica operat, praeventans escalationem supra-tensionis.
  • Pro systematibus resonans connectis, apparatum supra-tensiones transitorias et stationarias suppressit, securitatem recovery systematis assecurans.

Characteres Principales

  • Registratio datarum: Registat voltus, currentes et parametras fault pro analysi et resolutione problematum.
  • Celeris responsio: tempus actionis 30-40 ms, rapiditer reprimens arcu-ground fault.
  • Recuperatio automatica: Capax cito extinguendi arcus transitorios et restituendi operationem systematis.
  • Operatio extensa: Permittit retia operari usque ad 2 horas cum fault uniphasicis ground, minuendo tempus et costus intermissionis.
  • Protectio comprehensiva: Non affecta ab topologia systematis aut conditionibus operativis.
  • Alta fidelitas: Equipata cum monitor PT auxiliaris ad praeventionem malfuctionum.
  • Selectio fault sagax: Automatica identificans characteristica grounding, meliorans accurate.
  • Design flexibilis: Supportat plures modos operativos pro diversis configurationibus retialium.
Cognosce tui fornitori
Venditio Online
Ratio praestabilitae tradendae
Tempus responsionis
100.0%
≤4h
Brevis Descriptio Societatis
Locus Operis: 30000m² Numerus omnium laborantium: Summa Annua Exportatio (USD): 100000000
Locus Operis: 30000m²
Numerus omnium laborantium:
Summa Annua Exportatio (USD): 100000000
Servitia
Genus Negotii: Design/Fabricatio/Venditio
Categorias Principales: robot/Energia nova/Instrumenta inspectionis/apparatus electrum altum voltus/Apparatus electri bassa tensione/Instrumenta et mensurae
Gubernatio vitae
Servitia gestionis curae integralis pro quaestu, usu, conservatione et post-venditionem apparatus electricorum, securitatem operationis, continuationem imperii et usum electricitatis sine cura garantia.
Fornitori instrumentorum praeteritus est certificationem qualificationis platformae et iudicium technicum, ut ex fonte conformitas, professionalitas et fiducia servantur.

Producta Connexa

Cognitio Connexa

  • Quid est Definitio Energiae Electricae Formula Unitas Energiae Electricae
    Quid est Energia Electrica?Antequam explicemus quid sit energia electrica, conamur iterum perquirere differentia potentialis inter duo puncta in campus electricus.Ponamus differentiam potentialis inter punctum A et punctum B in campo electrico esse v volt.Secundum definitionem differentiae potentialis possumus dicere, si una unitas positiva electrica, id est corpus continens unam coulombum positivam, ab A ad B transierit, operis v joules faciet.Nunc, si non una coulombum, sed q coulomborum ab A
    03/09/2024
Non invenisti adhuc opportunos fornitoris ut te inveniant Citationem Nunc Accipe
Non invenisti adhuc opportunos fornitoris ut te inveniant
Citationem Nunc Accipe
Inquiry
+86
Click to upload file
Descarica
Obtine Applicatio Commerciale IEE-Business
Utiliza app IEE-Business ad inveniendum apparatus obtinendumque solutiones coniungendum cum peritis et participandum in collaboratione industriale ubique et semper propter totam supportionem tuorum projectorum electricitatis et negotiorum