High voltage disconnect switch trader 126kV 145kV 252kV 420kV 550kV

  • High voltage disconnect switch trader 126kV 145kV 252kV 420kV 550kV

Key attributes

Brand ROCKWILL
Model NO. High voltage disconnect switch trader 126kV 145kV 252kV 420kV 550kV
Rated voltage 550kV
Rated normal current 4000A
Rated frequency 50/60Hz
Rated peak value withstand current 160kA
Rated short-time withstand current 63kA
Series DS6B
Description

Product Introduction

The HV disconnect switch is outdoor high-voltage equipment for 50Hz/60Hz three-phase AC systems. This disconnect switch performs no-load line switching, circuit rearrangement and power flow regulation, while providing safe insulation for busbars, circuit breakers and other HV devices. The HV disconnect switch can switch inductive, capacitive and bus transfer current.
With a single-post double-arm scissor telescopic structure, the disconnect switch fits perfectly for busbar layout. It can be mounted directly under busbars with small footprint, delivering outstanding energy-saving benefits for substations with double busbars and bypass busbars.
Matched with JW10 earthing switch, the HV disconnect switch supports lower-layer busbar grounding; upper-layer busbars need independent earthing switches. 363kV and 550kV disconnect switch adopt SRCJ8 motor actuators for single-pole operation and three-pole linkage; 126kV and 252kV HV disconnect switch use SRCJ3 motor actuators for three-pole linkage. The earthing switch is fitted with SRCS manual actuator for synchronous three-pole operation.
The  disconnect switch has passed official industry certification. Its structural design and overall performance comply with national standards, reaching international advanced level of similar HV disconnect switch products.
The HV disconnect switch is composed of three single poles and actuators, including base, post insulator, operating insulator and conductive assembly. Conductive parts consist of gear box, foldable conductive arms and fixed contacts for overhead busbars.
Driven by the actuator and four-link scissor mechanism, the disconnect switch completes closing and opening operations, forming stable insulation clearance after switch-on.

Main Characteristics

  • Excellent conductive structure: Open layout with central conductor arrangement; balance spring adopts aluminum cover sealing. Key transmission parts are exposed for easy installation and debugging. Bearing with dust cover and sealed structure ensures good dustproof performance.
  • Large contact clamping area: Double-arm scissor structure enables wide rated contact coverage, making the HV disconnect switch suitable for both soft and hard busbars.
  • Open visible gear box, convenient for installation, debugging and maintenance. Integrated crank arm design reduces transmission links and improves efficiency and reliability. Double-bearing rotating shaft ensures flexible and stable operation of the disconnect switch.
  • Electromechanical separation design: Conductive components, springs and mechanical driving parts are isolated, avoiding current interference and improving the operational stability of the HV disconnect switch.
  • Supports one-key sequence control and double confirmation function expansion.

Main technical parameters

Among these voltage levels 225kV/230kV/330kV/345kV disconnect switches, the rated short-circuit breaking current is 63kA, and customization is available.

NO

Specifications

Unit

Value

1

Product model

 

DS6B-126D

DS6B-145D

DS6B - 252D

DS6B - 420D

DS6B-550D

Rated voltage

kV

126

145

252

420

550

3

1min power frequency withstand voltage (r.m.s)

Phase to phase to earth

kV

230

275

460

520

740

Across isolating distance

kV

230(+70)

315

460(+145)

610

740(+315)

4

Lightning impulse withstand voltage (peak 1.2/50μs)

Phase to phase to earth

kV

550

750

1050

1425

1675

Across isolating distance

kV

550(+100)

750

1050(+200)

1425(+240)

1675(+450)

5

Rated frequency

HZ

50/60

6

Rated current

A

2000/3150

2000/3150

2000/2500/3150/4000/5000

4000

4000

7

Rated short - time withstand current (r.m.s)

kA

50

104

125/160

164

160

8

Rated peak withstand current

kA

125

104

50/63

63

63

9

Rated short - circuit withstand time

S

3

3

3

2

3

10

Wiring terminal static mechanical load -

Longitudinal

N

1250

1250

2000

4000

4000

Horizontal

N

750

800

1500

2000

2000

Vertical

N

1000

1000

1250

1500

2000

11

Creepage distances

mm

3150,3906

3625,4495

6300,7812

10500,13020

13750

12

Mechanical life

Times

10000

13

Motor operating mechanism

Model

SRCJ7

SRCJ3

SRCJ8

14

Motor voltage

V

AC380/DC220

15

Control circuit’s voltage

V

AC220/DC220/DC110

16

Opening/closing time

S

12±1

16±1

17

Manual operating mechanism

Model

SRCS

18

Electromagnetic lock’s voltage

V

AC220/DC220/DC110

Applicable Service Conditions

This HV disconnect switch adapts to outdoor substation environments, suitable for conventional temperature, altitude and general polluted areas. It runs reliably in high-altitude, coastal humid and industrial corrosion sites with good seismic and anti-pollution performance.

Order Notice

  • Specify model, rated voltage, rated current, short-time withstand current and creepage distance for the disconnect switch.
  • Confirm whether the HV disconnect switch is matched with earthing switch.
  • Clarify soft or hard type of upper busbar.
  • Provide outer diameter of tubular busbar if required.
  • Select installation layout: cross-over or parallel arrangement for the disconnect switch.
  • Confirm actuator model, motor voltage, control voltage and auxiliary switch contact quantity.

FAQ for High voltage disconnect switch

Q: How do these 550kV disconnectors (Siemens, Hitachi, GE, and XD Group) perform in terms of key electrical parameters such as rated voltage, rated current, and withstand current?
A:

Basic Electrical Parameters

  • Rated Voltage: All four models from Siemens, Hitachi Energy, GE, and Pinggao are rated for 550 kV.

  • Rated Current: The Siemens, Hitachi, and Pinggao models are rated for 4000A. The GE PKG Gen3-550 offers a higher rated current of 5000A, making it suitable for applications with higher power flow requirements.

  • Short-Circuit Withstand: All models demonstrate identical performance, with a short-time withstand current of 63 kA for 3 seconds.

  • Peak Withstand Current: All models share the same peak withstand current rating of 171 kA.

Q: What are the interlocking regulations for bypass disconnectors in thermal power plants and substations?
A:
 The interlocking regulations for bypass disconnectors in thermal power plants and substations are as follows:
  • The bypass disconnector of each line can only be operated when the bypass circuit breaker is open and its bypass bus disconnector is closed. For the operation of the line bypass disconnector, it can only be operated when its outgoing line earthing switch is open.
  • The bypass bus-side disconnector of the bypass circuit breaker can only be operated when the bypass circuit breaker is open and the disconnector connected for bus tie operation is open.
  • The earthing switch on the bypass bus side of the bypass circuit can only be operated when the disconnector on the bypass bus side of the bypass circuit breaker is open.
  • The earthing switch on the bypass circuit breaker side of the bypass circuit can only be operated when the bypass circuit breaker and its bypass bus-side disconnector are open, and the disconnector connected for bus tie operation is open.

Know your supplier

Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 108000m² Total staff: 700+ Highest Annual Export(usD): 150000000
Services
Business Type: Design/Manufacture/Sales
Main Categories: High Voltage Electrical Apparatus/Electric transformer
Related Products
Related Knowledges
  • Installation Requirements and Procedures for 10 kV High-Voltage Disconnect Switches
    First, the installation of 10 kV high-voltage disconnect switches must meet the following requirements. The first step is to select an appropriate installation location, typically near the switchgear power supply in the power system to facilitate operation and maintenance. At the same time, sufficient space must be ensured at the installation site to accommodate equipment placement and wiring.Secondly, equipment safety must be fully considered—for example, lightning protection and explosion-proo
    11/20/2025
  • Common Issues and Handling Measures for 145kV Disconnector Control Circuits
    The 145 kV disconnector is a critical switching device in substation electrical systems. It is used in conjunction with high-voltage circuit breakers and plays an important role in power grid operation:First, it isolates the power source, separating equipment under maintenance from the power system to ensure personnel and equipment safety;Second, it enables switching operations to change the system operating mode;Third, it is used to interrupt small-current circuits and bypass (loop) currents.Re
    11/20/2025
  • What are the six operating principles of disconnect switches?
    1. Operating Principle of the DisconnectorThe operating mechanism of the disconnector is connected to the active pole of the disconnector via a connecting tube. When the main shaft of the mechanism rotates 90°, it drives the insulating pillar of the active pole to rotate 90°. The bevel gears inside the base drive the insulating pillar on the other side to rotate in the opposite direction, thereby achieving opening and closing operations. The active pole, through inter-pole linkage tubes, drives
    11/19/2025
  • 36kV Disconnect Switch Selection Guide & Key Parameters
    Selection Guidelines for 36 kV Disconnect SwitchesWhen selecting the rated voltage, ensure that the disconnect switch’s rated voltage is equal to or higher than the nominal voltage of the power system at the installation point. For example, in a typical 36 kV power network, the disconnect switch must have a rated voltage of at least 36 kV.For rated current, selection should be based on the actual long-term load current. Generally, the switch’s rated current must be no less than the maximum conti
    11/19/2025
  • Copper Conductor Size vs Temperature Rise in 145kV Disconnectors
    The relationship between the temperature-rise current of a 145 kV disconnector and copper conductor size lies in balancing current-carrying capacity and heat dissipation efficiency. The temperature-rise current refers to the maximum continuous current a conductor can carry without exceeding its specified temperature rise limit, and the copper conductor size directly influences this parameter.Understanding this relationship begins with the physical properties of the conductor material. Copper’s c
    11/19/2025
  • Design of an Intelligent Control System for Fully Enclosed Disconnectors in Distribution Lines
    Intelligentization has become an important development direction for power systems. As a critical component of the power system, the stability and safety of 10 kV distribution network lines are vital to the overall operation of the power grid. The fully enclosed disconnector, as one of the key devices in distribution networks, plays a significant role; thus, achieving its intelligent control and optimized design is of great importance for enhancing the performance of distribution lines.This pape
    11/17/2025
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.