Relais Tension Triphasé GRV8-03 ad 08

  • GRV8-03 to 08 3 Phase  Voltage Relay
  • GRV8-03 to 08 3 Phase  Voltage Relay
  • GRV8-03 to 08 3 Phase  Voltage Relay
  • GRV8-03 to 08 3 Phase  Voltage Relay
  • GRV8-03 to 08 3 Phase  Voltage Relay

Attributa principalia

Marca Switchgear parts
Numerus Modeli Relais Tension Triphasé GRV8-03 ad 08
Frequenta nominata 45Hz-65Hz
Series GRV8

Descriptiones productorum a fornitori

Descriptio

Relayta GRV8-03 ad 08 trium phasium voltage monitoring sunt claves ad stabilem operationem et securitatem apparatorum trium phasium systematum electricorum. Sua mensura alta precisione, optiones flexibilis configurationis, functiones tutelares fideles, et design compactus faciunt eam bene operari in variis scenariis applicationis sicut automatio industrialis, dispositiva mobilis, commutatio potentiae, et tutela potentiae. Elige series GRV8 ad praebendum solutionem professionalis et fidelis voltage monitoring pro tuo systemate electrico.
Caracteristica productu relayta GRV8-03 ad 08 trium phasium voltage monitoring:
1. Mensura vera RMS:
Per usu technologiae mensurae verae valoris effectivi, potest accurate reflectere actualis formam undae voltage reti, efficaciter respondere necessitatibus voltage monitoring in ambientibus distortionis harmonicae vel formae undae, et praebere plus fideles normas tutelares.
2. Lata optio rated voltage:
Praebet 8 standardis specifica rated voltage (GRV8-03 ad 08) ad eligendum, quae copiantur niveles mainstream industriales voltage mundiales, cum bona applicabilitate globali, simplificando electionem apparatorum et managementum inventarii.
3. Methodi flexibiles cabling:
Supportat duos communes methodos cabling trium phasium systematum, 3-phasa 3-wire (Delta) et 3-phasa 4-wire (Wye/Star), ad adaptandum ad differentes structuras rete distributionis.
4. Voltage monitoring alta precisione:
Precisione mensurae voltage est controlata intra ≤ 1% ad accurate determinandum status systematis voltage et evitandum maloperationem vel fallit tutelarum.
5. Indicatio status intuitiva:
Equipatus cum LED indicatoribus luminosis, clariter demonstrat currentis status operativus relay (sicut supply power, type fault, status output, etc.), facilitans diagnosin et maintenance velociter in situ.
6. Design compactus, spatio salvari:
Adoptans design ultra-thin, cum latitudine tantum 18mm, supportat installationem standard 35mm DIN rail, salvans pretiosum spatium installationis intus cabinetum controlis, specialiter aptum pro occasionibus spatio limitatis.

Advantages relayta GRV8-03 ad 08 trium phasium voltage monitoring:
1. Applicabilitas lata:
Multi specifica voltage et design dualis modi cabling satisfaciunt necessitatibus applicationis diversarum regionum et systematum mundiales.
2. Fidelitas alta:
Combinatio technologiae mensurae verae valoris effectivi et monitoring alta precisione assecurat accuratiam et temporelitatem actionum tutelaris in variis complexibus ambientibus rete.
3. Installatio facilis:
Corpus ultra-thin et compactum et methodus installationis standard DIN rail simplificat processum installationis et salvat spatium cabinetum controlis.
4. Maintenance intuitiva:
Indicatio status LED clara facilitat rapidam comprehensionem status apparatorum a operatoribus et facilitat troubleshooting et maintenance.
5. Cost-effectiveness alta:
Functiones trium phasium voltage monitoring et protectionis praebita ad costum rationabilem effective reducit periculum failure equipmenti et costus maintenance.

Parametri technici M460 M265
Function Monitoring 3-phase voltage
Terminali monitoring L1-L2-L3 L1-L2-L3-N
Terminali supply L1-L2 L1-N
Range voltage 220-230-240-380-400-415-440-460(P-P) 127-132-138-220-230-240-254-265(P-N)
Rated supply frequency 45Hz-65Hz
Range measuring 176V-552V 101V-318V
Voltage threshold adjustment 2%-20%of Unselected
Adjustment of asymmetry threshold 5%-15%
Hysteresis 2%
Phase failure value 70% of Un selected
Min=165V
70% of Un selected
Time delay Adjustable 0.1s-10s,10%
Measurement error ≤1%
Run up delay at power-up 0.5s time delay
Konb setting accuracy 10% of the scale value
Supply indication green LED
Output indication red LED
Reset time 1000ms
Output 1×SPDT
Current rating 10A/AC1
Switching voltage 250VAC/24VDC
Min. breaking capacity DC 500mW
Temperature coefficient 0.05%/℃,at=20℃(0.05%℉,at=68℉)
Mechanical life 1×107
Electrical life(AC1) 1×105
Operating temperature -20℃ to +55℃(-4℉ to 131℉)
Storage temperature -35℃ to +75℃(-22℉ to 158℉)
Mounting/DIN rail Din rail EN/IEC 60715
Protection degree IP40 for front panel/IP20 terminals
Operating position any
Overvoltage category III.
Pollution degree 2
Max.cable size(mm 2) solid wire max.1×2.5or 2×1.5/with sleeve max.1×2.5(AWG 12)
Tightening torque 0.8Nm
Dimensions 90×18×64mm
Weight   61g-66g
Cognosce tui fornitori
Venditio Online
Ratio praestabilitae tradendae
Tempus responsionis
100.0%
≤4h
Brevis Descriptio Societatis
Locus Operis: 1000m² Numerus omnium laborantium: Summa Annua Exportatio (USD): 300000000
Locus Operis: 1000m²
Numerus omnium laborantium:
Summa Annua Exportatio (USD): 300000000
Servitia
Genus Negotii: Venditio
Categorias Principales: pars componentium/Instrumenta inspectionis/apparatus electrum altum voltus/Apparatus electri bassa tensione/Instrumenta et mensurae/Instrumenta productiva/Ferramentae electricitatis
Gubernatio vitae
Servitia gestionis curae integralis pro quaestu, usu, conservatione et post-venditionem apparatus electricorum, securitatem operationis, continuationem imperii et usum electricitatis sine cura garantia.
Fornitori instrumentorum praeteritus est certificationem qualificationis platformae et iudicium technicum, ut ex fonte conformitas, professionalitas et fiducia servantur.

Producta Connexa

Cognitio Connexa

  • Culpae et Tractatio Terrae Unipolaris in Lineis Distributionis 10kV
    Characteristica et Instrumenta Detegendi Defectus Terrae Monofasiales1. Characteristica Defectuum Terrae MonofasialiumSigna Centralia Admonitionis:Campanula admonitionis sonat, et lucerna indicativa inscripta „Defectus Terrae in Sectione Omnibus [X] kV [Y]“ accenditur. In systematibus ubi punctum neutrum per bobinam Petersen (bobinam suppressionis arcus) ad terram connectitur, lucerna indicativa „Bobina Petersen Operatur“ etiam accenditur.Indicationes Voltmetri Monitoris Isolationis:Tensio phase
    01/30/2026
  • Modus operationis terre iunctae puncti neutralis pro transformatoribus retis electricitatis 110kV~220kV
    Dispositio modi operis terrae puncti neutralis pro transformatoribus rete electricitatis 110kV~220kV debet exigentias tolerationis insulationis puncti neutralis transformatorum complere, et simul conari ut impedimentum sequentiae nullae stationum transformationis fere immutatum maneat, dum certatur ne impedimentum sequentiae nullae compositum in quocumque puncto raptus circuiti systematis ultra ter impedimentum sequentiae positivae compositum excedat.Pro transformatoribus 220kV et 110kV in novis
    01/29/2026
  • Cur Quare Substationes Lapidem Gravem Calculos et Rupem Fractam Utuntur
    Cur Quare Substationes Utuntur Lapidibus, Gravibus, Piscinis et Saxis Tritis?In stationibus transformationis, instrumenta ut transformatores electricitatis et distributionis, lineae transmissionis, transformatores tensionis, transformatores currentis et commutatores disiunctionis omnia terram exigunt. Praeter terram, nunc profundius explorabimus cur gravia et saxa trita in stationibus transformationis saepe utuntur. Quamquam videantur ordinaria, isti lapides partem criticam iuxtaque functionalem
    01/29/2026
  • Cur autem nucleus transformatoris tantum in uno puncto terram tangere debet Nonne terra multipuncta fidelius est
    Cur ergo nucleus transformatoris terram tangere debet?In operatione, nucleus transformatoris, simul cum structuris, partibus et componentibus metallicis quae fixant nucleum et spiras, in forti campo electrico situs est. Sub influentia huius campi electrici, potentialem relativum altum ad terram comparatum acquirunt. Si nucleus non terra tangitur, differentia potentialis inter nucleum et structuras claudicantes et vas terratum existet, quae possit ad intermitterentiam dismissionem ducere.Praetere
    01/29/2026
  • Intellegere Terram Neutralis Transformatoris
    I. Quid est Punctum Neutrum?In transformatoribus et generatoribus, punctum neutrum est locus specificus in spira ubi absoluta tensio inter hunc locum et singula terminalia externa aequalis est. In diagrammate infra, punctumOrepraesentat punctum neutrum.II. Cur Punctum Neutrum Terrendum Est?Modus connexionis electricae inter punctum neutrum et terram in systemate AC triphasico diciturmodus terrendi puncti neutri. Hic modus directe afficit:Securitatem, fidem et oeconomiciam retelectrici;Selectione
    01/29/2026
  • Quid est Differentia Inter Transformatores Rectificatores et Transformatores Potentiae?
    Quid est transformator rectificans?"Conversio potentiae" est terminus generalis qui conversionem, inversionem et conversionem frequentiae comprehendit, inter quas conversio praecipue usitatissima est. Apparatus rectificans convertit potentiam AC input in DC output per rectificationem et filtrationem. Transformator rectificans servit ut transformator alimentationis pro talibus apparatibus rectificantibus. In applicationibus industrialibus, plerumque alimenta DC obtinentur per combinandum transfor
    01/29/2026
Non invenisti adhuc opportunos fornitoris ut te inveniant Citationem Nunc Accipe
Non invenisti adhuc opportunos fornitoris ut te inveniant
Citationem Nunc Accipe
Inquiry
+86
Click to upload file
Descarica
Obtine Applicatio Commerciale IEE-Business
Utiliza app IEE-Business ad inveniendum apparatus obtinendumque solutiones coniungendum cum peritis et participandum in collaboratione industriale ubique et semper propter totam supportionem tuorum projectorum electricitatis et negotiorum