• ODM factory GPRS Watt hour meter with 4G or 3G communication
  • ODM factory GPRS Watt hour meter with 4G or 3G communication
  • ODM factory GPRS Watt hour meter with 4G or 3G communication
ODM factory GPRS Watt hour meter with 4G or 3G communication
$90.00
Model
EM-230/5(30)
EM-230/5(32)
EM-230/5(40)
EM-230/5(45)
EM-230/5(50)
EM-230/5(80)
EM-230/5(100)
Basic info
Brand Wone
Model NO. ODM factory GPRS Watt hour meter with 4G or 3G communication
Rated voltage 230V
Rated normal current 5(30)A
Rated frequency 50(Hz)
Methods of Communication Bluetooth
Series D124066
Product Detail

Description

Meter support 4G communication, with fall back capability to 2G and 3G. The meter has three operating modes: STS token mode, currency prepaid mode and postpaid mode, which can be switched through communication. 

Features

  • Support load ground connection, bypass detection, open cover detection, influence of external magnetic field, abnormal voltage record, live&neutral wire metering.

  • Anti-tamper when Neutral missing: when Neutral missing, the meter still can work(battery support).

  • Divide into weekday timetable and weekend timetable, with 8 time period and 8 tariffs. Every timetable has a backup table for remote updating of backup timetable and configure the switching time. Meter will automatically switch the tariff table at the switching time.

  • Meter support 4G communication, with fall back capability to 2G and 3G.

  • Open cover, magnetic field, load ground connection, reserve current, over-voltage, low-voltage, low-frequency, overload, power-fail, low remaining power, and token record.

  • Meter measures voltage, current, active power, reactive power, frequency, power factor, MD in the current month, MD of last 1 month, MD of last 2 month, total output energy of the current month, total output energy of last 5 month, and total reactive energy.

  • Meter has 3 operation modes: STS token mode, currency prepaid mode and post-paid (traditional) mode, which can be switched.

  • And the currency mode can be divided into tariff mode and step price mode. Modes can be configured through communication.

  • Enter 20-digit token via keypad of meter or IHD, the meter display will be green Pic 1 if recharging is successful, will be red Pic 2 if is failed.

Specifications

Main
Range D124066
Product or Componet Type Energy meter
Country of origin China
Complementary
Phase Single Phase
Type of measurement

----

Metering type

Measurement

Device Application

Energy Charge

Accuracy class Active power 1.0 
Rated Current 5(100) A

Rated Voltage

230V

Network Frequency 50
Technology Type Electronic
Display Type LCD display(LCD 6+2 = 999999.99kWh)
Impulse Constant

1000imp/kWh(LED)   1000imp/kvarh

Maximum value measured 99999.99kWh
Tariff input 8 tariffs
Communication port protocol DLMS/COSEM(IEC62056)
Communication port support Bluetooth
Local signalling

------

Number of inputs -------
Number of Outputs --------------
Output voltage 230V
Mounting Mode Clip-on
Mounting Support ----
Connections - terminals

-------

Standards

IEC62052-11:2003, IEC62053-21:2003, IEC 62056-21,IEC62055-41:2018



Environment
IP degree of protection

IP54

Relative humidity <95%
Ambient air temperature for operation -20…70 °C
Ambient Air Temperature for Storage --30…80 °C
Operating altitude ---
Dimensions 176.8*117*58mm
Packing Units
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 178mm
Package 1 Width 119mm
Package 1 Length 60mm
Package 1 Weight 1.000kg



Connection Diagram

image.png



Dimensions


image.png









Know your supplier
Wone
Main Categories
High voltage/Low voltage/Wire cable/Instrument meters/New energy/Tester/Production equipment/Generator/Electrical fittings/Integrated Electrical Equipment
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$50,000,000
Professional Experience
1 years
Workplace
65666m²m²
占位
占位
Related Products
Related Knowledges
Analysis of Partial Discharge Principle (1)
Analysis of Partial Discharge Principle (1)
Analysis of Partial Discharge Principle (1)Under the action of an electric field, in an insulation system, discharge occurs only in some regions and does not penetrate between the conductors with the applied voltage. This phenomenon is called partial discharge. If partial discharge occurs near a conductor surrounded by gas, it can also be called corona.Partial discharge can occur not only at the edge of a conductor but also on the surface or inside an insulator. The discharge occurring on the su
Leon
07/19/2025
What types of FACTS controllers are there?
What types of FACTS controllers are there?
According to the type of connection FACTS Controller with the power system, it is classified as;Series Connected ControllerShunt Connected ControllerCombined Series-Series ControllerCombined Shunt-Series ControllerSeries-Connected ControllersSeries controllers introduce a voltage in series with the line voltage, typically using capacitive or inductive impedance devices. Their primary function is to supply or absorb variable reactive power as needed.When a transmission line is heavily loaded, the
Edwiin
07/19/2025
What are FACTS and related technologies?
What are FACTS and related technologies?
FACTS (Flexible Alternating Current Transmission System) refers to a power electronics-based system that uses static devices to enhance the power transfer capability and controllability of AC transmission networks.These power electronic devices are integrated into conventional AC grids to boost key performance metrics, including:Power transfer capacity of transmission linesVoltage stability and transient stabilityVoltage regulation precisionSystem reliabilityThermal limits of transmission infras
Edwiin
07/19/2025
What are the differences between HVAC and HVDC?
What are the differences between HVAC and HVDC?
Difference Between HVAC and HVDCElectricity generated in power plants is transmitted over long distances to electrical substations, which then distribute it to consumers. The voltage used for long-distance power transmission is extremely high, and we will explore the reasons for this high voltage later. Additionally, the transmitted power can be in either alternating current (AC) or direct current (DC) form. Therefore, power can be transmitted using either HVAC (High Voltage Alternating Current)
Edwiin
07/19/2025
What are the Advantages of HVDC over HVAC?
What are the Advantages of HVDC over HVAC?
What are the Advantages of HVDC over HVAC?Electricity travels long distances before reaching consumers. Power plants, often remote, supply electricity through hundreds of miles and multiple substations. High-voltage transmission reduces line losses, with both AC and DC used. Though AC is familiar via utility poles and home outlets, HVDC offers unique advantages in power transmission.The goal of power transmission is to minimize losses and costs. While both face influencing factors, HVDC has more
Edwiin
07/19/2025
Is the neutral - point grounding method of the power grid of 110kV and above only the neutral - point direct grounding method?
Is the neutral - point grounding method of the power grid of 110kV and above only the neutral - point direct grounding method?
Neutral - Point Grounding Modes and Protection of Transformers in Power GridsFor systems ranging from 110 kV to 500 kV, an effective grounding method shall be adopted. Specifically, under all operating conditions, the ratio of zero - sequence reactance to positive - sequence reactance X0/X1 of the system should be a positive value and not exceed 3. Meanwhile, the ratio of zero - sequence resistance to positive - sequence reactance R0/X1should also be a positive value and not exceed 1.In 330 kV a
Leon
07/19/2025
×
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!