• Product
  • Suppliers
  • Manufacturers
  • Solutions
  • Free tools
  • Knowledges
  • Experts
  • Communities
Search


Indoor high-voltage load break switch with fuse

  • Indoor high-voltage load break switch with fuse

Key attributes

Brand ROCKWILL
Model NO. Indoor high-voltage load break switch with fuse
Rated voltage 6kV
Rated normal current 400A
Rated frequency 50/60Hz
Series RMR
Description

Product Overview

The RMR - 12, RMR - 12R, and RMR - 12R/S load break switches are high - voltage electrical appliances installed indoors. They are suitable for AC 50Hz, 6kV or 10kV networks to break and close load and overload currents. They can also be used as switches for breaking and closing no - load long lines, no - load transformers, and capacitors. The load break switches with RN3 - type fuses (RMR - 12R, RMR - 12R/S) can cut off short circuits and be used as protection switches.This load break switch can be operated with CS3 - type and CS2 - type manual operating mechanisms.

Key Features

  • Multi - scenario Current Control:Suitable for 50Hz, 6kV/10kV AC networks. It can stably break and close load and overload currents, and also support the switching operations of no - load long lines, no - load transformers, and capacitors, covering multiple operation and maintenance scenarios of the distribution network.
  • Extended Short - circuit Protection:After being equipped with an RN3 - type fuse (such as the RMR - 12R series), it has the ability to cut off short - circuit currents. It can be used as a protection switch to provide short - circuit fault protection for equipment and lines, simplifying the protection configuration of the distribution network.
  • Installation Scenario Adaptation:With an indoor installation design and a compact structure, it is suitable for typical indoor power distribution facilities such as ring main units and box - type substations, meeting the construction and renovation needs of indoor power distribution systems in urban distribution networks, industrial and mining enterprises, etc.
  • Operating Mechanism Compatibility:It supports CS3 and CS2 - type manual operating mechanisms, adapts to different operating habits and existing equipment support systems, reduces the cost of renovation and replacement, and improves the flexibility of on - site operation and maintenance.
  • Mature Technical Architecture:Iterated based on the classic RMR series, it has stable arc - extinguishing performance, a long mechanical service life, and high long - term operation reliability, reducing the frequency of equipment failures and operation and maintenance workload.

Technical Parameters

Indoor high-voltage load break switch with fuse

Indoor high-voltage load break switch with fuse

Operating Environmental Conditions

  • Altitude: Not exceeding 1000 meters;
  • Ambient air temperature: Not higher than +40°C and not lower than -10°C;
  • Indoor places with air relative humidity not exceeding 90% (when the temperature is +25°C);
  • Environments free from conductive dust;
  • Environments free from corrosive gases that damage metals and insulation;
  • Places without severe vibration and impact;
  • Environments without fire and explosion hazards.

Know your supplier

Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 108000m² Total staff: 700+ Highest Annual Export(usD): 150000000
Services
Business Type: Design/Manufacture/Sales
Main Categories: High Voltage Electrical Apparatus/Electric transformer
Related Products
Related Knowledges
  • How has g3 technology changed the global climate?
    The Alternative to SF6 for High Voltage ApplicationsRemoving Greenhouse Gases from the GridNineteen of the warmest years on record have occurred since 2000, where greenhouse gases (GHGs) are at the root cause of climate change. Sulfur hexafluoride (SF₆), an insulating gas used in high-voltage switchgear, is estimated to contribute 23,500 times more than carbon dioxide (CO₂) to the greenhouse effect and can remain in the atmosphere for 3,200 years. Previously, Power Generation and Transmission ut
    05/09/2026
  • Difference Between Maintenance Earthing Switches and Fast Earthing Switches?
    Maintenance earthing switches and fast earthing switches (FES) are two types of switches with distinct characteristics.Maintenance Earthing SwitchesThese are typically configured alongside the disconnectors on both sides of a circuit breaker. Their sole purpose is to provide safety grounding on both sides of the circuit breaker during equipment maintenance.Fast Earthing Switches (FES)These are positioned on the line side of the outgoing disconnector in an outgoing circuit. They serve two primary
    05/08/2026
  • SiC MOSFET Solid State Circuit Breakers for Low Voltage Protection
    1. Core Principle SummaryIn simple terms, its core principle can be summarized as a three-step AC-DC-AC conversion, with the key step being to increase the frequency first, then transform the voltage.2. Working PrincipleRectification:First, the input line-frequency AC power (e.g., 50 Hz or 60 Hz) is rectified into DC power using power electronic devices (such as IGBTs). This step converts low-frequency AC into stable DC, preparing it for subsequent processing.High-Frequency Chopping (Inversion):
    05/03/2026
  • Solid-State Circuit Breakers Set to Revolutionize Circuit Protection
    Custom modules built with SiC MOSFETs minimize the impacts of short circuits and overloadsNearly every electrical engineer has wondered at some point whether it is possible to design a non-mechanical circuit breaker. There are plenty of reasons for this line of thought: would it not be better to use semiconductors to interrupt faults or handle overload conditions?However, deeper investigation inevitably reveals major obstacles. For one thing, the breakdown voltage of familiar power devices is ar
    05/03/2026
  • 2025 Complete Guide to Solar Cell Selection-Scenario Adaptation
    Solar Panel – Comprehensive Guide to Solar Cell SelectionA systematic selection reference for photovoltaic engineers and technicians, covering technical principles, key parameters, application scenarios and development trends.Data baseline: 2024–2025 industrial mass-production levels (CPIA data)1. The Role of Solar Cells in Photovoltaic SystemsMore than 90% of the conversion efficiency and power generation performance of PV modules are determined by solar cells. As the core semicondu
    05/03/2026
  • Technological Evolution of Silicon Carbide (SiC) Based DC Solid-State Circuit Breakers
    1. Introduction: Protection Challenges in the DC Distribution EraAs the global energy transition accelerates, DC microgrids, high-voltage DC (HVDC) power supplies for data centers, and large-scale energy storage systems have become critical components of power systems. However, DC systems lack a natural zero-crossing point and possess extremely low system impedance, leading to a rapid rate of rise of fault current (di/dt). Traditional mechanical circuit breakers, limited by millisecond-level ope
    04/25/2026
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.