Dead Tank Circuit Breakers for high performance- 12kV to 252kV

  • Dead Tank Circuit Breakers for high performance- 12kV to 252kV

Key attributes

Brand ROCKWILL
Model NO. Dead Tank Circuit Breakers for high performance- 12kV to 252kV
Rated voltage 252kV
Rated normal current 4000A
Rated frequency 50/60Hz
Rated short circuit breaking current 50kA
Series RHD
Description

Product introduction

As China's first source factory specializing in GIS tank circuit breakers, we hold a pioneering position in the industry with decades of accumulated technical experience. Leveraging advanced R&D capabilities and mature manufacturing technologies, our products are widely recognized for their market-leading reliability and performance.

RHD-40.5/72.5/138/145/252 Dead Tank circuit breaker is a new generation of open high-voltage electrical equipment developed independently ,The tank type circuit breaker is composed of the entrance bushing, lead-out bushing, CT, arc extinguishing chamber, chassis, operating mechanism, etc. It can be used in the high-cold and high-altitude area, At present, the new generation of tank products have reached the leading domestic and international advanced level in advanced technology and quality reliability.

Main characteristic

  •  Good anti-seismic performance, the product is equivalent to the seismic grade of GlS.

    • Horizontal arrangement of arc extinguishing chamber, low center of gravity.

    • Auto seismic frequency: The porcelain column breaker is about 4.5 Hz, and the tank circuit breaker is about 13.5 Hz.

  • The electric tracing band solution can be used in the high-cold region, which can not be realized by the porcelain column circuit breaker.

  • The product can be used in an area of 5000m , the standard configuration of the arc extinguishing chamber & drive system can only be fixed with the height of the outlet casing.

  •  The tank type circuit breakers integrates the straight through current transformer, the product covers a small area the quality is stable, and the on-site maintenance work is small. At the same time, it solves the problems such as the small margin of CT insulation ,the limitation of CT capacity and the high cost ,aging, cracking and explosion of the CT.

  •  Design of an arc extinguishing chamber:Horizontal Structure, it adopts thermal expansion and auxiliary pressure gas extinguishing technology, which has small operation work, excellent breaking performance and more than 20 electrical life.

  • Environment adaptability:It is suitable for severe environment conditions (such as severe pollution, water fog, hall, etc.), high - altitude area, high altitude area, earthquake area, the box body is sealed with air bag type, and the body protection grade is lP66.

  • The CT of variable ratio and multi-level combination can be attached, high accuracy, easy to add capacity, and meet 80% or the operating frequency voltage under the value of 5Pc, can be configured with TPY.

  •  Complete CT protection measures: CT shell is sealed at both ends of the shell and has special ant-condensation design.

  • The light spring operating mechanism adopts the overall cast aluminum frame. Breaking spring , closing spring and buffer are arranged in a centralized manner, and all adopt spiral double pressure spring, compact structure, not easy to fatigue.

  • The product is small, with integrated design, integrated supply, integrated installation conditions.

  • With the breaking capacity of the 4000A back-to-back capacitor bank.

Main technical parameters

Among these, some SF6 tank circuit breakers cover non-standard voltage levels including Customizable Voltage Ratings: 12kV-252kV with a rated short-circuit breaking current of 50kA or 63kA, and we offer customization services.

NO

Name

Unit

Data

1

Rated voltage

kV

40.5

72.5

145

252

2

Operational altitude

M

≤5000

3

Operating ambient   temperature

-40~55

4

Operating pollution   class

Class

5

Wind speed resistance

m/s

34

6

Aseismatic class

 

AG5

Order Notice:

  • Model and format of circuit breaker.

  • Rated electrical parameters (voltage, current, break current, etc).

  • Working conditions for using (environment temperature, altitude, and environment pollution level).

  • Operating voltage of operating mechanism and motor voltage.

  • The number of current transformer, current ratio, class combination and secondary load.

  • Names and quantities of spare items needed, parts and special equipment and tools(to be otherwise ordered).

 

Documentation Resource Library Dead Tank circuit breaker

Restricted
Dead Tank Circuit Breakers Catalog
Catalogue
English
Consulting
Restricted
138kV Station Switchgear Technical Specification with IEC
Technical Data
Chinese
Consulting
Restricted
138kV Station Switchgear Technical Specification with IEEE&ANSI
Technical Data
English
Consulting

FAQ for Dead Tank circuit breaker

Q: What are the structural characteristics of the tank circuit breaker?
A:

Integral Tank Structure:

  • Integral Tank Structure: The breaker's arc quenching chamber, insulating medium, and related components are sealed within a metal tank filled with an insulating gas (such as sulfur hexafluoride) or insulating oil. This forms a relatively independent and sealed space, effectively preventing external environmental factors from affecting the internal components. This design enhances the insulation performance and reliability of the equipment, making it suitable for various harsh outdoor environments.

Arc Quenching Chamber Layout:

  • Arc Quenching Chamber Layout: The arc quenching chamber is typically installed inside the tank. Its structure is designed to be compact, enabling efficient arc quenching within a limited space. Depending on different arc quenching principles and technologies, the specific construction of the arc quenching chamber may vary, but generally includes key components such as contacts, nozzles, and insulating materials. These components work together to ensure that the arc is quickly and effectively extinguished when the breaker interrupts the current.

Operating Mechanism:

  • Operating Mechanism: Common operating mechanisms include spring-operated mechanisms and hydraulic-operated mechanisms.

  • Spring-Operated Mechanism: This type of mechanism is simple in structure, highly reliable, and easy to maintain. It drives the opening and closing operations of the breaker through the energy storage and release of springs.

  • Hydraulic-Operated Mechanism: This mechanism offers advantages such as high output power and smooth operation, making it suitable for high-voltage and high-current class breakers.

Q: What are the leakage rate requirements for the arc quenching chamber of a tank-type circuit breaker?
A:

The leakage rate of SF₆ gas must be controlled at an extremely low level, typically not exceeding 1% per year. SF₆ gas is a potent greenhouse gas, with a greenhouse effect 23,900 times that of carbon dioxide. If a leak occurs, it can not only cause environmental pollution but also lead to a decrease in the gas pressure within the arc quenching chamber, affecting the performance and reliability of the circuit breaker.

To monitor the leakage of SF₆ gas, gas leakage detection devices are typically installed on tank-type circuit breakers. These devices help to promptly identify any leaks so that appropriate measures can be taken to address the issue.

Q: What are the requirements for monitoring the gas decomposition products of the SF6 tank circuit breaker?
A:

During the normal operation and interruption processes of a circuit breaker, SF₆ gas can decompose, producing various decomposition products such as SF₄, S₂F₂, SOF₂, HF, and SO₂. These decomposition products are often corrosive, toxic, or irritating, and therefore require monitoring.If the concentration of these decomposition products exceeds certain limits, it may indicate abnormal discharges or other faults within the arc quenching chamber. Timely maintenance and handling are necessary to prevent further damage to the equipment and to safeguard personnel health.

Q: What are the core differences and key selection points of SF6 tank circuit breakers with voltage levels of 138kV/145kV/252kV?
A:

145kV is a mainstream standard grade in China, 138kV is an American standard specification, and 252kV is suitable for higher-voltage scenarios. Core differences and selection points: ① Insulation and parameters — the break spacing and rated SF6 pressure (0.7MPa) of 252kV are both higher than the other two; 138kV and 145kV can share some structures but require adjustment of the voltage sampling threshold; ② Key selection points — 138kV prioritizes matching interfaces of imported equipment, 145kV focuses on maturity, and 252kV needs to verify the breaking capacity of ≥63kA and the insulation coordination test report.

Know your supplier

Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 108000m² Total staff: 700+ Highest Annual Export(usD): 150000000
Services
Business Type: Design/Manufacture/Sales
Main Categories: High Voltage Electrical Apparatus/Electric transformer
Related Products
Related Knowledges
  • Case Studies of Installation and Manufacturing Defects in 110kV HV Circuit Breaker Porcelain Insulators
    1. SF6 gas leakage occurred in the ABB LTB 72 D1 72.5 kV circuit breaker.Inspection revealed gas leakage at the fixed contact and cover plate area. This was caused by improper or careless assembly, where the dual O-rings slipped and were misplaced, resulting in gas leakage over time.2. Manufacturing Defects on the Outer Surface of 110kV Circuit Breaker Porcelain InsulatorsAlthough high-voltage circuit breakers typically have their porcelain insulators protected with covering materials during tra
    12/16/2025
  • Overview of Defect Diagnosis Methods for High-Voltage AC Circuit Breakers
    1. What are the characteristic parameters of the coil current waveform in high-voltage circuit breaker operating mechanisms? How to extract these characteristic parameters from the original trip coil current signal?Answer: The characteristic parameters of the coil current waveform in high-voltage circuit breaker operating mechanisms may include the following: Steady-state peak current: The maximum steady-state current value in the electromagnet coil waveform, representing the position where the
    12/16/2025
  • Chinese tank-type filter manufacturer successfully develops 550 kV tank-type filter bank circuit breaker.
    Good news has come from a Chinese tank-type filter manufacturer: its independently developed 550 kV tank-type filter bank circuit breaker has successfully passed all type tests, marking the official completion of the product’s development.In recent years, with the continuous growth of electricity demand, power grids have placed increasingly higher performance demands on electrical equipment. Keeping pace with the times, the Chinese tank-type filter manufacturer has actively responded to the nati
    11/19/2025
  • Hydraulic Leak & SF6 Gas Leakage in Circuit Breakers
    Leakage in Hydraulic Operating MechanismsFor hydraulic mechanisms, leakage can cause short-term frequent pump starting or excessively long re-pressurization time. Severe internal oil seepage in valves may lead to pressure loss failure. If hydraulic oil enters the nitrogen side of the accumulator cylinder, it can cause abnormal pressure rise, which affects the safe operation of SF6 circuit breakers.Apart from failures caused by damaged or abnormal pressure detection devices and pressure component
    10/25/2025
  • 500kV SF₆ tank circuit breaker insulation pull rod discharge fault cause analysis and treatment
    As a key component of circuit breakers, the insulating pull - rod is an important insulating and transmission part of Gas - Insulated Switchgear (GIS) equipment. It is required to have high reliability in terms of mechanical and electrical properties. Generally, insulating pull - rods rarely malfunction, but once a failure occurs, it can have serious consequences for the circuit breaker.The 550kV circuit breaker in a certain power station has a single - break horizontal arrangement, with the mod
    05/21/2025
  • Research on the Application Mode and Operation Monitoring of Tank-type Circuit Breaker Heating Tapes in 500kV Substations in High-Cold Areas
    At present, most low - voltage switchgear assemblies in China mainly use SF₆ gas at a pressure of 0.5 - 0.6 MPa as the insulating medium. However, when the ambient temperature drops to around - 32.5°C, the SF₆ gas will quickly liquefy, resulting in serious problems with the insulation and interrupting capabilities of the product. To avoid affecting the operation of low - voltage switchgear assemblies in alpine regions, tracing heaters are often used to prevent the liquefaction of SF₆ gas