series 150 A commutatoris ex terna operatione de IEE-Business

  • cooper power series 150 A externally operated tap-changer switch
  • cooper power series 150 A externally operated tap-changer switch

Attributa principalia

Marca Transformer Parts
Numerus Modeli series 150 A commutatoris ex terna operatione de IEE-Business
Votum nominatum 35kV
currus electricus nominatus 150A
Numerus phaseorum Three phase
Tensio sustentans frequentia industriale 50kV/min
Numerus interfacium 7-Position
Typus contactus installandi "T" Handle
Series cooper power series

Descriptiones productorum a fornitori

Descriptio

Generalis
Pericula quae ad manualem mutationem internam tap distributorum transformatorum cum suis Cooper Power™ series 150 A externa operata tap-changer switch eo quod lineae manipuli non necesse est exponi conductoribus altae tensionis et calidis fluidis transformatorum.

Tap-changer commutatores eliminant necessitatem demontandi transformatores tignorum pro adjustmente tensionis et expositione interioris tank transformatoris ad contaminationem. Illi sunt designati pro usu in distributorum transformatoribus repletis oleo transformatorio, Envirotemp™ FR3™ fluido, vel aequivalente approbato.

Tap-changer commutatores sunt disponibiles cum quinque aut septem positionibus commutationis, et pro applicationibus sidewall- vel covermounted. Corpus commutatoris, rotor, et axis facti sunt ex materia polyester altae fortitudinis plena vitre. Axis operativus est sigillatus contra effluvium per duos Viton® O-rings resistentes altae temperaturae. Sigillum conicum compressionem controllat et praeventit overtightening.

Tap-changer commutator est keyt ad parietem tank ut praeventur movimentum corporis commutatoris durante commutatione. Positiones commutatoris facile mutantur per extractionem manubri spring-loaded, vertendo eum ad positionem desideratam, et permitto pointer cadere in placida index slotted. Manubrium operativum pad-lockable magis leverage praebet, manu operari potest et habet screw lock. Facile legibiliter litterae albae elevatae in placido nigrum index clare identificant positionem commutatoris.
Omnes cuprum, parva resistencia, pinch-type contacts self-wiping connections praebent. Pro facilitate connectionis, bolt tabs, bolt tabs cum 1/4-20 stud, 16-14 AWG, 12-10 AWG, 8 AWG vel 6 AWG crimp terminales disponibiles sunt. Commutatores cum crimp terminalibus habent foramina tappata inboard additionalia pro faciendo separatim connectiones ring tongue terminal sine mutatione contactuum commutatoris. Omnes terminales habent recessus hex ad tenendum capita boltonum 7/16 inch hex de hardware standard 1/4 inch pro rapidis, facilis connectionibus.

 

Si plus parametrorum noscere opus est, quaesumus catalogum datae inspecta.↓

Vel benigne nos continge.→


 

Bibliotheca Documentorum Rerum
Restricted
cooper power series 150 A externally operated tap-changer switch catalog data
Operation manual
English
Consulting
Consulting
Cognosce tui fornitori
Venditio Online
Ratio praestabilitae tradendae
Tempus responsionis
100.0%
≤4h
Brevis Descriptio Societatis
Locus Operis: 1000m² Numerus omnium laborantium: Summa Annua Exportatio (USD): 300000000
Locus Operis: 1000m²
Numerus omnium laborantium:
Summa Annua Exportatio (USD): 300000000
Servitia
Genus Negotii: Design/Venditio
Categorias Principales: Ferramentae electricitatis
Gubernatio vitae
Servitia gestionis curae integralis pro quaestu, usu, conservatione et post-venditionem apparatus electricorum, securitatem operationis, continuationem imperii et usum electricitatis sine cura garantia.
Fornitori instrumentorum praeteritus est certificationem qualificationis platformae et iudicium technicum, ut ex fonte conformitas, professionalitas et fiducia servantur.

Producta Connexa

Cognitio Connexa

  • Accidentia Transformatoris Principalis et Questiones Operationis Gas Luminis
    1. Registri accidentis (XIX Martii, MMXIX)Hora XVI:XIIX die XIX Martii, MMXIX, monitorium background reportavit actionem gas levis transformatoris principis numeri III. Conformiter Codex Operationis Transformatorum Electricitatis (DL/T572-2010), personale operationis et maintenance (O&M) inspectavit statum in situ transformatoris principis numeri III.Confirmatio in situ: Panel non-electricus protectionis WBH transformatoris principis numeri III reportavit actionem gas levis phase B corpus tr
    02/05/2026
  • Culpae et Tractatio Terrae Unipolaris in Lineis Distributionis 10kV
    Characteristica et Instrumenta Detegendi Defectus Terrae Monofasiales1. Characteristica Defectuum Terrae MonofasialiumSigna Centralia Admonitionis:Campanula admonitionis sonat, et lucerna indicativa inscripta „Defectus Terrae in Sectione Omnibus [X] kV [Y]“ accenditur. In systematibus ubi punctum neutrum per bobinam Petersen (bobinam suppressionis arcus) ad terram connectitur, lucerna indicativa „Bobina Petersen Operatur“ etiam accenditur.Indicationes Voltmetri Monitoris Isolationis:Tensio phase
    01/30/2026
  • Modus operationis terre iunctae puncti neutralis pro transformatoribus retis electricitatis 110kV~220kV
    Dispositio modi operis terrae puncti neutralis pro transformatoribus rete electricitatis 110kV~220kV debet exigentias tolerationis insulationis puncti neutralis transformatorum complere, et simul conari ut impedimentum sequentiae nullae stationum transformationis fere immutatum maneat, dum certatur ne impedimentum sequentiae nullae compositum in quocumque puncto raptus circuiti systematis ultra ter impedimentum sequentiae positivae compositum excedat.Pro transformatoribus 220kV et 110kV in novis
    01/29/2026
  • Cur Quare Substationes Lapidem Gravem Calculos et Rupem Fractam Utuntur
    Cur Quare Substationes Utuntur Lapidibus, Gravibus, Piscinis et Saxis Tritis?In stationibus transformationis, instrumenta ut transformatores electricitatis et distributionis, lineae transmissionis, transformatores tensionis, transformatores currentis et commutatores disiunctionis omnia terram exigunt. Praeter terram, nunc profundius explorabimus cur gravia et saxa trita in stationibus transformationis saepe utuntur. Quamquam videantur ordinaria, isti lapides partem criticam iuxtaque functionalem
    01/29/2026
  • Cur autem nucleus transformatoris tantum in uno puncto terram tangere debet Nonne terra multipuncta fidelius est
    Cur ergo nucleus transformatoris terram tangere debet?In operatione, nucleus transformatoris, simul cum structuris, partibus et componentibus metallicis quae fixant nucleum et spiras, in forti campo electrico situs est. Sub influentia huius campi electrici, potentialem relativum altum ad terram comparatum acquirunt. Si nucleus non terra tangitur, differentia potentialis inter nucleum et structuras claudicantes et vas terratum existet, quae possit ad intermitterentiam dismissionem ducere.Praetere
    01/29/2026
  • Intellegere Terram Neutralis Transformatoris
    I. Quid est Punctum Neutrum?In transformatoribus et generatoribus, punctum neutrum est locus specificus in spira ubi absoluta tensio inter hunc locum et singula terminalia externa aequalis est. In diagrammate infra, punctumOrepraesentat punctum neutrum.II. Cur Punctum Neutrum Terrendum Est?Modus connexionis electricae inter punctum neutrum et terram in systemate AC triphasico diciturmodus terrendi puncti neutri. Hic modus directe afficit:Securitatem, fidem et oeconomiciam retelectrici;Selectione
    01/29/2026
Non invenisti adhuc opportunos fornitoris ut te inveniant Citationem Nunc Accipe
Non invenisti adhuc opportunos fornitoris ut te inveniant
Citationem Nunc Accipe
Inquiry
+86
Click to upload file
Descarica
Obtine Applicatio Commerciale IEE-Business
Utiliza app IEE-Business ad inveniendum apparatus obtinendumque solutiones coniungendum cum peritis et participandum in collaboratione industriale ubique et semper propter totam supportionem tuorum projectorum electricitatis et negotiorum