7.6KVPole Mounted 32 Step Single Phase Oil Immersed Type Voltage Regulator 译为拉丁语: Regulator Voltae Immersae in Oleum Unipolaris Scalae 32 Fixus in Columna 7.6KV

  • Continuous / Step voltage regulation step voltage regulator 6kV 6.35kV 11kV 15kV 22kV 33kV – IEEE

Attributa principalia

Marca ROCKWILL
Numerus Modeli 7.6KVPole Mounted 32 Step Single Phase Oil Immersed Type Voltage Regulator 译为拉丁语: Regulator Voltae Immersae in Oleum Unipolaris Scalae 32 Fixus in Columna 7.6KV
Votum nominatum 11kV
Frequenta nominata 50/60Hz
Numerus phaseorum Single-phase
Series RVR

Descriptiones productorum a fornitori

Descriptio

Product Overview

RVR-1 uniphasis step voltage regulator est autotransformator oleoimmersus cum integrato on-load tap changer, designatus ad automaticam stabilisationem distributionis lineae voltaginis. Offert ±10% regulationem in 32 finibus gradibus (circa 0.625% quilibet), certans consistentiam voltaginis per variabilia conditionia oneris.

Gradus voltaginis ab 2,500V (60 kV BIL) ad 19,920V (150 kV BIL), cum capacitatibus currentis ab 50A ad 1665A et kVA ratingibus ab 38.1 ad 1000. Unitas compatibilis est cum systematis 50Hz et 60Hz et potest instaurari in pole-mounted, pad-mounted, vel in substationibus.

Product Features

  • Precise Voltage Regulation
    ±10% adjustment in 32 automatic steps (approx. 0.625% per step)

  • Digital Controller
    Programmable settings, communication (optional: GPRS/GSM/Bluetooth), and data logging

  • Flexible Installation
    Supports pole mounting with brackets, pad-mount base, or substation mounting with optional elevating platforms

  • Versatile Voltage Matching
    Equipped with internal potential taps or external ratio correction transformer for system compatibility

Key Advantages

  • Certified Quality
    ISO9001 & ISO14001 certified; each unit is fully type-tested before delivery

  • Robust & Reliable
    Built for harsh environments with minimal maintenance requirements

  • Flexible Packaging Options
    Export-grade seaworthy wooden boxes available in single or double-unit formats to reduce shipping cost

  • Professional Support
    Fast pre-sales response, real-time production updates, and long-term after-sales service

Application Scenarios

  • Rural & Urban Distribution Networks
    Compensates for voltage drops along long feeder lines

  • Industrial Zones
    Ensures voltage stability for large machinery and sensitive equipment

  • Renewable Energy Integration
    Maintains voltage stability in grids with wind or solar input

  • Substation Use
    Enhances voltage control across secondary distribution systems

Technical Specifications

Bibliotheca Documentorum Rerum
Restricted
6kV to 34.5kV Single Phase Automatic Voltage Regulator Brochure
Catalogue
English
Consulting
Consulting
FAQ
Q: Quomodo normae IEEE selectionem regulatorum tensionis graduali 33kV tangunt
A:

Standard IEEE C57.15/C57.116 definivit requisitos essentiales pro regulatoribus 33kV:

  • Severitas Experimenti: Imperat tolerationem impulsi fulminis (110kV) et experimenta elevationis caloris (max 55°C)

  • Protocollae Securitatis: Postulat dispositiva delevionis pressionis et tolerationem currentis defectus (25kA/2s)

  • Metricae Praestantiae: Specificat accurateam tensionis ±0.5% et efficaciam minimam 96% a 50-100% oneri

  • Valorem Conformitatis: Modello certificato ab IEEE securitatem compatibilitatis rete et facilitat processus approbationis utilitatis
    Hae standardes directe correlant ad vita servitii longior 20% et costus maintenance reducere 35% in deploymentibus agri.

Q: Quid est differentia inter regulam tensionis continuam et gradatim in regulatoribus tensionis gradatim?
A:

Regulatores tensionis graduali duos modos distinctos correctionis tensionis praebent:

  • Regulatio Gradualis: Tensionem in incrementis fixis (typice ±10% in gradu 0.625-1.25%) per mutatores tap adiustat. Idonea pro reticulis stabilibus ubi adiustamenta accurata sufficient.

  • Regulatio Continua: Correctionem lenem, sine gradibus, per conversionem electronicae potestatis praebet. Perfecta pro reticulis volatilibus cum fluctuationibus frequentibus (exempli gratia, zonas integrationis renovabilium).
    Omnes formae (6kV-33kV) normis IEEE C57.15 obtemperant, cum versiones gradualis 32 positiones mutatorum tap et versiones continuae ±1% accurate output sub omnibus conditionibus oneris conservantes.

Cognosce tui fornitori
Venditio Online
Ratio praestabilitae tradendae
Tempus responsionis
100.0%
≤4h
Brevis Descriptio Societatis
Locus Operis: 108000m²m² Numerus omnium laborantium: 700+ Summa Annua Exportatio (USD): 150000000
Locus Operis: 108000m²m²
Numerus omnium laborantium: 700+
Summa Annua Exportatio (USD): 150000000
Servitia
Genus Negotii: Design/Fabricatio/Venditio
Categorias Principales: apparatus electrum altum voltus/transformator
Gubernatio vitae
Servitia gestionis curae integralis pro quaestu, usu, conservatione et post-venditionem apparatus electricorum, securitatem operationis, continuationem imperii et usum electricitatis sine cura garantia.
Fornitori instrumentorum praeteritus est certificationem qualificationis platformae et iudicium technicum, ut ex fonte conformitas, professionalitas et fiducia servantur.

Producta Connexa

Cognitio Connexa

  • Impactus Praejudicialis Bias Directi Currentis in Transformeribus ad Stationibus Energiae Renovabilis Proximis Electrodis Terrae UHVDC
    Impactus DC Bias in Transformeribus ad Stationes Energeticae Renovabiles Proximas Electrodis Terrae UHVDCCum electrum terrae systematis transmissionis Ultra-Alta-Voltura Directa (UHVDC) sit prope stationem energeticae renovabilis, currus reditus per terram fluens potest causare incrementum potentialis terrae circa aream electri. Hoc incrementum potentialis terrae ducit ad mutationem potentialis puncti neutri transformatorum proximorum, inducendo bias DC (vel offset DC) in eorum nucleis. Talis bi
    01/15/2026
  • HECI GCB for Generators – Cepus SF₆ Circuit Breaker
    1. Definitio et Functio1.1 Munus Interruptoris Circuiti GeneratorisInterruptor Circuitus Generatoris (GCB) est punctum disiunctionis controllabile situatum inter generator et transformator incrementalis, servans ut interficium inter generator et rete electricitatis. Principales eius functiones includunt isolationem defectuum lateris generatoris et facilitationem controlis operationis durante synchronizatione generatoris et connectione ad rete. Principium operativum GCB non differt significanter
    01/06/2026
  • Apparatus Distributionis Transformatorisque Experimentatio Inspectio et Conservatio
    1. Manutentio et Inspectio Transformatoris Aperi interruptorem circuitus bassae tensionis (LV) transformatoris in manu, remove fusum alimenti controlis, et pende signum “Noli Claudere” super manubrium commutationis. Aperi interruptorem circuitus altae tensionis (HV) transformatoris in manu, claudi commutatorem terrae, exsolvare totaliter transformatorem, claude armarium interruptoris HV, et pende signum “Noli Claudere” super manubrium commutationis. Pro manutentione transformatoris sicci: primo
    12/25/2025
  • Quomodo Resistentiam Isolationis Transformatorum Distributionis Probes
    In operibus practicis, resistentia insulationis transformatorum distributionis saepe bis metitur: resistentiam inter spiram alti voltaginis (HV) et spiram bassi voltaginis (LV) plus vasum transformatoris, et resistentiam inter spiram LV et spiram HV plus vasum transformatoris.Si ambae mensurationes valores acceptabiles praebent, indicat quod insulatio inter spiram HV, spiram LV, et vasum transformatoris est probata. Si una mensuratio deficiat, testes pairwise resistentiae insulationis inter omne
    12/25/2025
  • Principia Design pro Transformeribus Distributionis in Columna Fixis
    Principia Design Pro Distributionibus Transformerum in Polum Fixis(1) Principia Locorum et DispositionumPlataformae transformerum in polum fixarum debent collocari iuxta centrum oneris aut prope onera critica, secundum principium “parva capacitas, plura loca” ad facilitatem substitutionis et maintenance. Ad distributionem electricitatis domesticam, transformatores triphasici possunt instaurari iuxta necessitatem praesentem et projectiones futurorum incrementorum.(2) Selectio Capacitatis pro Tran
    12/25/2025
  • Solutio Controlis Stridoris Transformatorum pro Diversis Installationibus
    1. Mitigatio sonoris pro camera transformatoris independente in superficie terraeStrategia mitigationis:Primum, fac inspectionem et maintenance cum potestate interrupta, includens renovationem olei insulantis vetustatis, examinationem et consolidationem omnium fixorum, et mundationem pulvis a unitate.Deinde, reficere fundamentum transformatoris vel installare dispositiva isolationis vibrationis—ut gommae vel isolatores springalis—selecta secundum gravitatem vibrationis.Tandem, fortificare insula
    12/25/2025

Solutiones Relatae

  • Design Solution of 24kV Siccum Aera Insulatum Ring Main Unit
    Combinatio Solidi Insulationis Adiuvantis + Insulationis Aereae Siccae repraesentat directionem pro RMU 24kV. Per requirementa insulationis cum compactitate equilibrata et adiuvante solidum insulationis, testes insulationis sine magnificatione significativa dimensionum inter phasos et inter phasos et terram transigi possunt. Inclusio columnae pole solidificat insulationem pro interruptore vacuo et conductoribus eius coniunctis.Maintinendo spatium phasorum exiens 24kV ad 110mm, intensitas electri
    08/16/2025
  • Optimizatio Design Schematum pro Unitate Circulorum Principalium Aere Insulata 12kV ad Minuendam Probabilitatem Disruptionis Emissionis
    Cum celeri progressus industriae electricitatis, conceptus ecologicus de carbonis minore, energiae servanda, et conservatione ambientis profundissime integratus est in designum et fabricam productorum electricorum pro distributione et generatione electricitatis. Unitas Distributiva Circuli (RMU) est dispositivum electricum clavem in retibus distributionis. Securitas, conservatio ambientis, fides operativa, efficacia energetica, et oeconomia sunt tendentiae inevitabiles in eius progressu. RMUs tr
    08/16/2025
  • Analyse communium problematum in unitatibus principali circuitu isolatis gas 10kV (RMUs)
    Introductio:​​RMUs insulati gaseis 10kV sunt amplissime usitati propter multas suas utilitates, sicut quod sint perfecte clausi, habeant excellentem insulativam qualitatem, non requirant maintenance, sint compacti, et praebent installationem flexibilem et commodam. In hoc stadio, paulatim facti sunt nodus criticus in rete distributionis urbano anulari et iocabuntur partem significativam in systemate distributionis electricitatis. Difficultates in RMUs insulatis gaseis possunt graviter impingere
    08/16/2025
Instrumenta Libera Cognata
Non invenisti adhuc opportunos fornitoris ut te inveniant Citationem Nunc Accipe
Non invenisti adhuc opportunos fornitoris ut te inveniant
Citationem Nunc Accipe
Inquiry
Descarica
Obtine Applicatio Commerciale IEE-Business
Utiliza app IEE-Business ad inveniendum apparatus obtinendumque solutiones coniungendum cum peritis et participandum in collaboratione industriale ubique et semper propter totam supportionem tuorum projectorum electricitatis et negotiorum