Intelligent Dual Power Controller

  • Intelligent Dual Power Controller
  • Intelligent Dual Power Controller

Key attributes

Brand Rw Energy
Model NO. Intelligent Dual Power Controller
Rated voltage 230V ±20%
Rated frequency 50/60Hz
Electric energy consumption ≤5W
Series RWD-LC
Description

Description

With the development of society, people have higher and higher requirements for power supply reliability. In many cases, two power supplies are used to ensure the reliability of power supply, which requires a product to switch reliably between two power supplies. The intelligent dual power automatic conversion device produced by our company is mainly composed of a high-voltage vacuum circuit breaker with electric dual isolation and a dual power intelligent backup self-input controller. Applied to AC 50HZ, rated voltage 12KV, rated current up to 1250A dual power supply system, when one power failure or undervoltage occurs, the isolation switch automatically switches to the other, the whole process automatically switches to the other normal power supply. Reliable guarantee of continuity of power supply

The controller has a variety of protection functions such as short circuit, three-stage overcurrent, single-phase ground, undervoltage, reclosing and prepaid, which effectively avoids unnecessary re-supply shock when the load fails. When the common power supply fails, the switching device can automatically switch with the standby power supply to ensure reliability and safety. It is especially suitable for important places where power is not allowed, as an important electrical control device to ensure continuous power supply, it is a self-throwing self-restoring dual power automatic switching device matching with high voltage vacuum circuit breaker. The products are widely used in 10kV distribution lines in oil fields and mines, and 10kV lines in industrial and mining enterprises to ensure real-time power supply of important loads. It has the characteristics of small footprint, small investment, convenient debugging and maintenance, and is an ideal switchgear for realizing power supply automation.

Support communication methods: wireless (GSM/GPRS/CDMA), Ethernet, WIFI, optical fiber, power carrier, RS232/485,RJ45, etc., and can access other station equipment (such as TTU, FTU, DTU, etc.).

Main function introduction

1. Protection relay functions:

AST    Double line Protection,

49     Thermal Overload (Over load), 

50 Three-section of Overcurrent (Ph.OC),

50G/N/SEF Sensitive Earth Fault (SEF),

27/59 Under/Over Voltage (Ph.OV/Ph.UV), 

51C Cold load pickup (Cold load).

2. Supervision functions:

60CTS CT Supervision,

60VTS VT Supervision. 

3. Control functions:

79 Auto Reclose,

86 Lockout>>>>>>.

circuit-breaker control.

4. Monitoring Functions: 

1) Primary currents for Phases and Zero sequence current,

2) Primary PT Voltage,

3) Frequency,

4) Binary Input/Output status, 

5) Trip circuit healthy/failure,

6) Time and date,

7) Fault records,

8) Event records.

5. Data Storage functions:

1) Event Records,

2) Fault Records,

3) Measurands

Technology parameters

 paramete.png

Device structure

RWD-LC-尺寸.png

双电源控制器的应用方案.png

About customization

The following optional functions are available: Upgrade SMS Function. Upgrade RS485/RS232 socket.

For detailed customization, please contact the salesman.

Q: What is a high voltage dual power switch?

A: The high-voltage dual power switch is a device used to automatically switch between two high-voltage power supplies. When one power supply fails (such as power failure, abnormal voltage, etc.), it can quickly switch the load to another normal power supply to ensure the continuity of power supply.

Q: Where is it mainly used?

A: In hospitals, data centers, large factories and other places where continuity of power supply is highly required. For example, during hospital surgery, a sudden power outage may endanger the patient's life, and the use of high-voltage dual power switch can avoid this situation.

Q: How fast does it switch?

A: Generally speaking, the switching time can reach the millisecond level, which can minimize the time of load power failure and avoid damage to the equipment.

Documentation Resource Library Recloser Controllers

Restricted
RWK-38 Line Sectionalizing Load Break Switch Controller electrical drawing
Drawings
English
Consulting
Restricted
RWK-38 Line Sectionalizing Load Break Switch Controller installation drawing
Drawings
English
Consulting

Certifcations Recloser Controllers

FAQ for Recloser Controllers

Q: What input voltage ranges does the digital voltmeter support, and is it compatible with global power systems?
A:

It supports universal input ranges (e.g., AC 0-600V, DC 0-1000V) and wide power supply (AC 85-265V), compatible with 110V/220V/380V power systems in Europe, America, Asia and other regions, meeting global industrial application needs.

Q: Could you explain more details about OC1, OC2, and OC3?
A:

Three-Section Overcurrent Protection is a coordinated protection scheme widely used in power systems to detect and isolate faults (e.g., short circuits) while ensuring selective tripping. It consists of three stages with distinct operating characteristics based on current magnitude and time delay:

  1. Instantaneous Overcurrent Protection (Section I)

Function: Responds immediately to severe overcurrents exceeding a high-set threshold (e.g., 5–10 times the rated current).

Purpose: Rapidly clears close-in faults (near the protection device) to prevent equipment damage.

Key Feature: No intentional time delay (operates in milliseconds).

  1. Time-Delayed Overcurrent Protection (Section II)

Function: Triggers after a predefined short delay (e.g., 0.1–0.5 seconds) for moderate overcurrents (e.g., 2–5 times the rated current).

Purpose: Handles faults farther from the protection device, allowing downstream breakers to clear localized faults first (selectivity).

Coordination: Employs a time-graded scheme—higher fault currents (closer faults) trip faster, while lower currents (remote faults) trip slower.

  1. Backup Overcurrent Protection (Section III)

Function: Activates after a longer time delay (e.g., several seconds) for low-magnitude overcurrents (e.g., 1.2–2 times the rated current).

Purpose: Serves as a backup for primary protection (Sections I/II) and addresses overloads or persistent faults.

Characteristic: May use an inverse-time curve (trip time decreases as current increases).

Coordination Principle

The three sections work hierarchically:

Section I clears severe faults instantly.

Section II handles moderate faults with short delays, prioritizing system selectivity.

Section III provides backup protection, ensuring reliability if upstream protections fail.

This layered approach minimizes outage scope, balances speed and selectivity, and enhances grid stability.

Q: Can this device be upgraded to firmware in the future?
A:

Sure, this device cannot be upgraded online, but it requires offline firmware version upgrade using a burning device to upgrade more features or fix known bugs. As this device is a customized product, you need to provide us with the device's model number and version number when upgrading. Once we have determined the upgrade plan, we will contact you and provide you with the burning device and firmware upgrade package needed for the upgrade.

Know your supplier

Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 30000m² Total staff: 100 Highest Annual Export(usD): 100000000
Services
Business Type: Design/Manufacture/Sales
Main Categories: High Voltage Electrical Apparatus/Low Voltage Electrical Apparatus/Instrument meters/New energy/Tester/Robot
Related Products
Related Knowledges
  • Surge Arrester Structure and Electrical Testing Technology
    1.Critical Role of Surge Arresters in Power System Overvoltage ProtectionThe surge arrester serves as the primary line of defense against overvoltage in power systems. Its operational status directly determines the insulation safety of major equipment such as transformers, motors, and switchgear. Zinc Oxide Arresters (MOA), with their superior non-linear voltage-current characteristics, have become the most widely used protective devices in modern grids. Deeply understanding their internal confi
    04/11/2026
  • Comprehensive Comparison of Energy Efficiency Standards for Three-Phase Power Transformers
    1. OverviewThe national standard for "Minimum Allowable Values of Energy Efficiency and the Energy Efficiency Grades for Power Transformers" has undergone a major update. The new version, GB 20052-2024, was issued on April 29, 2024, and is scheduled for official implementation on February 1, 2025, at which time it will fully replace the current GB 20052-2020.This revision aligns with China's "Dual Carbon" goals, aiming to further enhance the energy efficiency of power equipment, phase out outdat
    04/10/2026
  • Technical Comparison of Recloser PMA vs SOM Mechanisms
    As devices that frequently break fault currents, recloser operating mechanisms must meet requirements for high consistency, extremely short opening and closing times, and tens of thousands of mechanical cycles. Traditional spring-operated mechanisms (SOM) achieve operation through mechanical energy storage and complex linkage systems, whereas permanent magnetic actuators (PMA) introduce direct electromagnetic drive and magnetic latching. As engineers with 29 years of experience, we know that mec
    04/08/2026
  • 110kV Transformer Partial Discharge Ultrasonic Localization Technology
    Importance of Partial Discharge Localization in 110kV Live Line TestingPartial discharge (PD) serves as a critical early warning sign of insulation deterioration within 110kV transformers. If left undetected, persistent discharge can cause irreversible carbonization of the oil-paper insulation, eventually leading to catastrophic dielectric failure. In the context of 110kV substation maintenance, ultrasonic localization has emerged as a primary diagnostic tool due to its high immunity to electrom
    04/08/2026
  • Main Transformer Accidents and Light Gas Operation Issues
    1. Accident Record (March 19, 2019)At 16:13 on March 19, 2019, the monitoring background reported a light gas action of No. 3 main transformer. In accordance with the Code for Operation of Power Transformers (DL/T572-2010), operation and maintenance (O&M) personnel inspected the on-site condition of No. 3 main transformer.On-site confirmation: The WBH non-electrical protection panel of No. 3 main transformer reported a Phase B light gas action of the transformer body, and the reset was ineff
    02/05/2026
  • Faults and Handling of Single-phase Grounding in 10kV Distribution Lines
    Characteristics and Detection Devices for Single-Phase Ground Faults1. Characteristics of Single-Phase Ground FaultsCentral Alarm Signals:The warning bell rings, and the indicator lamp labeled “Ground Fault on [X] kV Bus Section [Y]” illuminates. In systems with a Petersen coil (arc suppression coil) grounding the neutral point, the “Petersen Coil Operated” indicator also lights up.Insulation Monitoring Voltmeter Indications:The voltage of the faulted phase decreases (in
    01/30/2026
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.