• Low-Loss Three-Phase Photovoltaic Isolation Transformer
Low-Loss Three-Phase Photovoltaic Isolation Transformer
discuss personally
Model
SG-1250kVA
SG-300kVA
Basic info
Brand ROCKWILL
Model NO. Low-Loss Three-Phase Photovoltaic Isolation Transformer
Rated frequency 50/60Hz
Rated capacity 1250kVA
Phases Three-phase
Series SGG
Product Detail

Product Overview:

For many years, our company has specialized in manufacturing SD/SG(YSD) series single-phase and three-phase dry-type transformers dedicated to mechanical equipment, with capacities ranging from 1KVA to 3000KVA. Developed by referencing the latest similar products from Siemens, our SG series three-phase dry-type transformers not only provide voltage transformation in the power grid but also isolate third harmonics from the grid to equipment, reducing heat generation in machines and extending the service life of insulating materials. They are particularly suitable for imported equipment (380V input → 220V output, 380V input → any voltage output, 220V input → any voltage output) with specifications from 1KVA to 3000KVA.

Our SG and DG series dry-type isolation transformers are widely applicable to various power supply scenarios with AC 50-60HZ and input/output voltages not exceeding 3000V. All parameters, including input/output voltage levels, connection groups, tap positions, winding capacity distribution, secondary winding configurations, and whether a casing is required, are meticulously designed and manufactured according to user requirements.

Material Configuration Description of Transformer:

Transformers serve as the main components of various power supplies and electrical equipment. Isolation transformers consist of cylindrical windings and laminated cores, where the core is stacked with brand-new high-quality high-silicon silicon steel sheets using fully mitered joints. Our company employs advanced manufacturing processes, including imported Max high-speed automatic winding machines and a full set of vacuum pressure impregnation (VPI) equipment. The windings are formed using the skeletonless full-series winding method, and the transformers undergo vacuum impregnation to achieve insulation classes of F (155℃) or H (180℃).The input and output voltages of the transformer can be designed according to customer requirements, available in various specifications such as single-phase, three-phase, or multiple-way input/output configurations.

  •  Core:Made of brand-new high-quality high-silicon silicon steel sheets, mainly with materials of 0.35mm thick H18, H14, H12, and Z11 high-quality silicon steel sheets. We select the most suitable material based on customer requirements and usage conditions to optimize the transformer's performance design. (Conventional material: brand-new high-quality silicon steel sheets).

  • Wire:Using PEW, UEW, EIW, SEIW, FEAI enameled wires and glass fiber-covered wires, with temperature resistance grades of F (155℃), H (180℃), HC (200℃), and C (220℃). (Conventional temperature resistance grade: H grade, 180℃).

  • Insulating Materials:Adopting high-temperature resistant insulating paper as the insulating material, which has multiple properties of high-temperature insulation, flame retardancy, and moisture resistance.

  •  Insulating Material Terminal Blocks

  • For low-power applications: Using terminal blocks, which feature a beautiful appearance and excellent voltage resistance, temperature resistance, and flame retardant properties.

  • For high-power applications: Using high-quality copper busbars.

  •  Iron Feet:Mainly made of CNC bent cold-rolled steel plates, with environmentally friendly electroplating options such as multicolor plating (golden yellow), blue zinc (silver white), white zinc (ivory white), and surface anodizing (black).

Technical data:

Product Operating Conditions:

  • Applicable altitude: ≤ 5000m

  • Ambient temperature: -15℃~+45℃

  • Relative humidity: ≤ 90%

  • The installation site shall be free of gases, vapors, chemical deposits, dirt, conductive dust that seriously affect the insulation strength of the transformer, and free of other explosive, flammable, and corrosive substances.

Know your supplier
ROCKWILL
Rockwill Electric Group Global Manufacturer of High voltage and medium-voltage power equipment and smart grid solutions. Headquartered in Wenzhou, China. Serving 100+ countries with quality, innovation, and trust. What We Offer: • HV-MV switchgear (VCB, SF₆ circuit breakers, RMU, GIS) • Distribution transformers and substations • Smart grid and monitoring systems • Solar, wind, EV charging, and energy storage solutions • EPC turnkey power projects Certified: ISO 9001 / ISO 14001 / ISO 45001
Main Categories
High voltage
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$150,000,000
Professional Experience
16 years
Workplace
108000m²m²
占位
占位
Related Products
Related Knowledges
Analysis of Partial Discharge Principle (1)
Analysis of Partial Discharge Principle (1)
Analysis of Partial Discharge Principle (1)Under the action of an electric field, in an insulation system, discharge occurs only in some regions and does not penetrate between the conductors with the applied voltage. This phenomenon is called partial discharge. If partial discharge occurs near a conductor surrounded by gas, it can also be called corona.Partial discharge can occur not only at the edge of a conductor but also on the surface or inside an insulator. The discharge occurring on the su
Leon
07/19/2025
What types of FACTS controllers are there?
What types of FACTS controllers are there?
According to the type of connection FACTS Controller with the power system, it is classified as;Series Connected ControllerShunt Connected ControllerCombined Series-Series ControllerCombined Shunt-Series ControllerSeries-Connected ControllersSeries controllers introduce a voltage in series with the line voltage, typically using capacitive or inductive impedance devices. Their primary function is to supply or absorb variable reactive power as needed.When a transmission line is heavily loaded, the
Edwiin
07/19/2025
What are FACTS and related technologies?
What are FACTS and related technologies?
FACTS (Flexible Alternating Current Transmission System) refers to a power electronics-based system that uses static devices to enhance the power transfer capability and controllability of AC transmission networks.These power electronic devices are integrated into conventional AC grids to boost key performance metrics, including:Power transfer capacity of transmission linesVoltage stability and transient stabilityVoltage regulation precisionSystem reliabilityThermal limits of transmission infras
Edwiin
07/19/2025
What are the differences between HVAC and HVDC?
What are the differences between HVAC and HVDC?
Difference Between HVAC and HVDCElectricity generated in power plants is transmitted over long distances to electrical substations, which then distribute it to consumers. The voltage used for long-distance power transmission is extremely high, and we will explore the reasons for this high voltage later. Additionally, the transmitted power can be in either alternating current (AC) or direct current (DC) form. Therefore, power can be transmitted using either HVAC (High Voltage Alternating Current)
Edwiin
07/19/2025
What are the Advantages of HVDC over HVAC?
What are the Advantages of HVDC over HVAC?
What are the Advantages of HVDC over HVAC?Electricity travels long distances before reaching consumers. Power plants, often remote, supply electricity through hundreds of miles and multiple substations. High-voltage transmission reduces line losses, with both AC and DC used. Though AC is familiar via utility poles and home outlets, HVDC offers unique advantages in power transmission.The goal of power transmission is to minimize losses and costs. While both face influencing factors, HVDC has more
Edwiin
07/19/2025
Is the neutral - point grounding method of the power grid of 110kV and above only the neutral - point direct grounding method?
Is the neutral - point grounding method of the power grid of 110kV and above only the neutral - point direct grounding method?
Neutral - Point Grounding Modes and Protection of Transformers in Power GridsFor systems ranging from 110 kV to 500 kV, an effective grounding method shall be adopted. Specifically, under all operating conditions, the ratio of zero - sequence reactance to positive - sequence reactance X0/X1 of the system should be a positive value and not exceed 3. Meanwhile, the ratio of zero - sequence resistance to positive - sequence reactance R0/X1should also be a positive value and not exceed 1.In 330 kV a
Leon
07/19/2025
×
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!