• Product
  • Suppliers
  • Manufacturers
  • Solutions
  • Free tools
  • Knowledges
  • Experts
  • Communities
Search


15kV/1250A MV buitelukse vakuum outomatiese sirkuitreklaar

  • 15kV/1250A MV outdoor vacuum Auto Circuit recloser
  • 15kV/1250A MV outdoor vacuum Auto Circuit recloser
  • 15kV/1250A MV outdoor vacuum Auto Circuit recloser

Sleutelkenmerke

Handelmerk ROCKWILL
Modelnommer 15kV/1250A MV buitelukse vakuum outomatiese sirkuitreklaar
Gedraaide Spanning 15kV
Gedraaide stroom 1250A
Gedekte korte-sirkuitverbrekingstroom 25kA
Hoogfrequentie-spanningstoetsing 28kV/min
Gedekte blikseminslag spanning 95kV
Handmatige sluiting Yes
Meganiese slot No
Reeks RCW

Produkbeskrywings van die voorsienier

Beskrywing

Beschrywing:

Die RCW reeks outomatiese sirkuit-herlukkers kan gebruik word op oorkoppeling verspreidingslyne asook vir verspreidingsubstasie toepassings vir alle spangradowe van 11kV tot 38kV by 'n 50/60Hz kragstelsel. En die bepaalde stroom kan 1250A bereik. Die RCW reeks outomatiese sirkuit-herlukkers integreer die funksies van beheer, beskerming, meting, kommunikasie, foutopsporing, aanlyn monitering van sluiting of opening. Die RCW reeks vakuum herlukker is hoofsaaklik gekombineer met integrasie eindpunt, stroomtransformator, permanente magneet aktuator en sy herlukkerbestuurder.

Eienskappe:

  • Opsionele graads beskikbaar in die bepaalde stroomreeks.

  • Met opsionele relaibeskerming en logika vir gebruikerskeuse.

  • Met opsionele kommunikasie protokolle en I/O poorte vir gebruikers om te kies.

  • PC sagteware vir bestuurder toetsing, instelling, programmering, opdaterings.

Parameters

image.png

image.png


Omgewingsvereistes:

image.png

Produk wys:

不代手合正方形硅橡胶永磁.png

带手合正方形 硅橡胶永磁带手合.png

Wat is die vakuum boogblus fout van buite vakuum herlukkers en sy oplossing?

Vakuum Boogblussing Kamer Foute:

  • Verlaagde Vakuumvlak: Dit is 'n algemene probleem met vakuum boogblussing kamers. Die vakuum boogblussing kamer vertrou op 'n hoëvakuum om bogen te blus. As die vakuumvlak verlaag, sal sy isolasievermoë en boogblusvermoë beduidend verswak. Oorsake van 'n verlaagde vakuumvlak kan insluit swak sigting, soos verouderde of beskadigde sigtingsmateriaal, of piepkleine lekke tydens die vervaardigingsproses. Wanneer die vakuumvlak na 'n sekere punt verlaag, kan dit gelei tot onvolledige boogblussing tydens stroomonderbreking, wat gevolglik boogherontbranding en verdere lynfoute veroorsaak.

  • Kontakverslet: Tydens frekwente oop- en sluitoperasies, kan die kontakte van die vakuum boogblussing kamer as gevolg van boogerosi verslet raak. Kontakverslet verhoog kontakweerstand, wat kan lei tot ernstige verhitting van die kontakte wanneer normale stroom deurloop, wat die normale werking van die toerusting beïnvloed. Bovendien, tydens foutstroomonderbreking, kan die kontakte nie die hoë stroom hanteer nie, wat gevolglik kontakswelding of foute om die stroom te onderbreek, veroorsaak.

Oplossings vir Vakuum Boogblussing Kamer Foute:

Verlaagde Vakuumvlak:

  • Meet Vakuumvlak: Gebruik gespesialiseerde vakuumvlakmeetinstrumente, soos vakuumvlaktesters, om gereeld die vakuumvlak van die vakuum boogblussing kamer te kontroleer. Een die vakuumvlak gevind word om onder die spesifiseerde waarde te wees, moet die vakuum boogblussing kamer vinnig vervang word.

  • Vervang Sigtings: As jy vermoed dat swak sigting die verlaagde vakuumvlak veroorsaak, kontroleer en vervang die sigtings. Wanneer jy sigtings vervang, verseker jy dat jy hoëkwaliteit, kompatibel sigtingsmateriaal gebruik en die korrekte installasieprosedures volg om verdere lekkasies te voorkom.

Kontakverslet:

  • Gereelde Inspeksie: Kontroleer gereeld die verslettoestand van die kontakte deur waarneming vensters of deur die toestel te demontereer. Op grond van die mate van verslet, as die verslet die spesifiseerde limiet oorskry, moet die kontakte vinnig vervang word.

  • Optimaliseer Bedryfsparameters: Analiseer die oorsake van kontakverslet, soos of dit as gevolg van frekwente operasies of oormatige bedryfstroom is. As die probleem frekwente operasies is, oorweeg dan om die herlukker se herlukstrategie te optimaliseer om onnodige oop- en sluitoperasies te verminder. As die probleem oormatige bedryfstroom is, kontroleer die lynlasttoestande, pas die beskermingsinstellings aan, en vermy om die kontakte bloot te stel aan oormatige stroomimpakte.


Dokumentasie hulpbronbiblioteek
Restricted
Specification for 11kV Vacuum Automatic Recloser by Kenya Power and Lighting Company Limited (KPLC)
Other
English
Consulting
Consulting
Restricted
BREB 11kV Automatic Circuit Reclose Specification Submission Sheet
Other
English
Consulting
Consulting
Restricted
11kV Automatic Circuit Reclose Standard for Class III in Bangladesh
Other
English
Consulting
Consulting
Restricted
15 kV Pole Mount Auto Recloser Technical Specifications for Guyana Power & Light Incorporated (GPL)
Other
English
Consulting
Consulting
Restricted
15kV Switching Station requirements in Ethiopia
Other
English
Consulting
Consulting
Restricted
15kV/27kV/38kV outdoor auto break vacuum recloser brochure
Brochure
English
Consulting
Consulting
Restricted
10 to 38kV auto vacuum break recloser Catalog
Catalogue
English
Consulting
Consulting
Restricted
15kV automatic recloser technology specification
Technical Data Sheet
English
Consulting
Consulting
FAQ
Q: Wat is die hooftegnologiese alternatiewe vir SF6-gasvrye skakelaars?
A:

1. Vriendelike gasgemengde insulasietegnologie
CO ₂ en perfluorketon/nitriel menggase: soos CO ₂/C ₅ - PFK (perfluorketon) of CO ₂/C ₄ - PFN (perfluornitriel) menggase. Hierdie menggase kombinéer die booguitwysingsvermoë van CO ₂ en die hoë dielektriese sterkte van perfluorinerde ketone/nitrile, wat dit 'n vervanger maak vir SF ₆ in hoogspanningsvlakke. Byvoorbeeld, CO ₂/C ₄ - PFN menggas word kommersieel aangebring in hoogspanningskreukbrekers, met insulasie- en uitwysingsprestasie dalk naby aan SF ₆, en 'n beduidend verlaagde globale opwarmingpotensiaal (GWP).
Lug en perfluorketon menggas: In mediumdruktoepassings kan die mengsel van lug en C ₅ - PFK gebruik word as 'n insulasie-medium. Deur die mengverhouding en druk te optimaliseer, kan insulasieprestasie vergelykbaar met SF ₆ bereik word terwyl omgewingsimpak verminder word.
2. Vakuumkreukbreker-tegnologie
Vakuumbooguitwysingskamer: Deur die hoë insulasiekracht en vinnige booguitwysingsvermoë in 'n vakuumomgewing te gebruik, vervang dit die booguitwysingsfunksie van SF ₆. Vakuumkreukbrekers word wyd toegepas in die medium- en laespanningsvlakke, veral in scenario's met hoë omgewingsvereistes. Sy voordele is geen broeikasgas-emissies en uitsonderlike booguitwysingsprestasie, maar dit moet probleme soos vakuumsealing en kontakmateriaal oplos.
Kombinasie van vakuumkreukbreker en gasinsulering: In sommige mediumspanningsuitskakelaars word vakuumkreukbrekers gebruik as breek-elemente, gekombineer met droë lug of stikstof as insulasie-media, om omgewingsvriendelike gasgeïnsuleerde uitskakelaars (GIS) te vorm wat 'n balans tussen insulasie- en booguitwysingsprestasie bewaar.

Q: Wat is die verskil tussen 'n vakuum-sirkuiteil en 'n SF-sirkuiteil?
A:
  1. Hul kernverskil is die boogverdelende media: Vakuumonderbrekers gebruik 'n hoë vakuum (10⁻⁴~10⁻⁶Pa) vir isolering en boogverdeling; SF₆-onderbrekers verlaat op SF₆-gas, wat elektrone goed absorbeer om bogen te doof.
  2. Vir spanningsaanpassing: Vakuumonderbrekers is geskik vir medium-laagspanning (10kV, 35kV; sommige tot 110kV), selde 220kV+. SF₆-onderbrekers is geskik vir hoë-ultra hoëspanning (110kV~1000kV), hoofstroom vir ultra-hoëspanningsnetwerke.
  3. Vir prestasie: Vakuumonderbrekers doof bogen vinnig (<10ms), het 'n 63kA~125kA onderbreekvermoë, is geskik vir gereelde gebruik (bv. kragverspreiding) met langer leeftyd (>10,000 siklusse). SF₆-onderbrekers uitmunt in stabiele groot/induktiewe stroomonderbreking, maar werk minder gereeld, benodig insulasieverwysingtyd na uitslukking.
Ken u lewerancier
Online winkel
Punte tydlewering
Reaksietyd
100.0%
≤4h
Bedryfsomsig
Werkplek: 108000m²m² Totale personeel: 700+ Hoogste Jaarlikse Uitvoer (VSA): 150000000
Werkplek: 108000m²m²
Totale personeel: 700+
Hoogste Jaarlikse Uitvoer (VSA): 150000000
Dienste
Geselsaakstype: Ontwerp/Vervaardiging/Verkope
Hoofdskategorieë: Hoëspanningstoerusting/transformator
Levenslange garantiebeheerder
Heel Lewensorg Sorg Dienste vir toerustingverskaffing, gebruik, instandhouding en naverkoop, om veilige bedryf van elektriese toerusting, deurlopende beheer en sorgvrye elektrisiteitsverbruik te verseker
Die toerustingverskaffer het platformkwalifikasiesertifisering en tegniese evaluering deurgegaan, wat aan die bron nakoming, professionele standaarde en betroubaarheid verseker.

Verwante produkte

Verwante Kennis

Verwante Oplossings

Nog nie die regte verskaffer gevind nie? Laat goedgekeurde verskaffers jou vind. Kry Praatskaart Nou
Nog nie die regte verskaffer gevind nie? Laat goedgekeurde verskaffers jou vind.
Kry Praatskaart Nou
Stuur navraag
Laai af
Kry die IEE-Business-toepassing
Gebruik die IEE-Business app om toerusting te vind kry oplossings verbind met kenners en neem deel aan bedryfsamenwerking waar en wanneer ook al volledig ondersteunend van jou kragprojekte en besigheidsgroei