24kV Indoor metal-clad with drawable MV Switchgear

  • 24kV Indoor metal-clad with drawable MV Switchgear

Key attributes

Brand ROCKWILL
Model NO. 24KV Indoor metal-clad with drawable MV Switchgear
Rated voltage 24kV
Rated frequency 50/60Hz
Series KYN28-24
Description

Description:

China KYN28 indoor metal-clad with drawable switchgear(hereafter short as swithgear) is a complete power distribution device for 3.6~24KV, 3 phase AC 50Hz, single bus sectionalized system. It is mainly used for power transmission of middle/small generators in power plants, power receiving, transmission for substations in power distribution and power system of factories, mines and enterprises, and starting of large high-voltage motor,etc, so as to control, protect and monitor the system. The switchgear meets IEC298, GB3906-91. In addition to be used with domestic VS1 vacuum circuit breaker, it can be used with VD4 from ABB, 3AH5 from Siemens domestic ZN65A, and VB2 from GE, etc. It is truly a power distribution deviece with good performance.

In order to meet the requirement for wall mounting and front-end maintenance, the switchgear is equipped with a special current transformer, so that the operator can maintain and inspect it in front of the cubicle.

Service environment:

  •  Ambient temperature: Maximum temperature:+40℃     Minimum temperature: -15℃.

  •  Ambient humidity: Daily average RH no more than 95%;Monthly average RH no more than 90%.

  • Altitude no higher than 2500m.

  •  The air around without any pollution of duty,smoke,ercode or flammable air,steam or salty fog.

Technical parameters:

24kV Indoor metal-clad with drawable MV Switchgear.png

What are the technical parameters of indoor metal armored traction medium-voltage switchgear?

Rated Voltage:

  • 24kV: This parameter determines the insulation level and other related electrical performance design criteria for the switchgear.

Rated Current:

  • Common rated current specifications include 630A, 1250A, 1600A, 2000A, 3150A, etc. The specific value should be determined based on the size of the connected load to ensure that the equipment can safely and stably carry and distribute electrical power.

Rated Short-Circuit Breaking Capacity:

  • Typically ranges from 20kA to 31.5kA. This parameter reflects the switchgear's ability to interrupt short-circuit currents. The rated short-circuit breaking capacity must be greater than the maximum possible short-circuit current in the power system to ensure reliable interruption of fault currents during a fault, preventing the accident from escalating and maintaining the safe and stable operation of the power system.

Protection Class:

  • Generally, the protection class is IP4X or higher. The protection class indicates the enclosure's ability to protect against the ingress of external objects and water. An IP4X protection class prevents the entry of solid objects larger than 1.0mm in diameter into the switchgear, as well as accidental entry of foreign objects or tools, thus effectively protecting the normal operation of internal electrical components.


Know your supplier

Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 108000m²m² Total staff: 700+ Highest Annual Export(usD): 150000000
Services
Business Type: Design/Manufacture/Sales
Main Categories: High Voltage Electrical Apparatus/Electric transformer
Related Products
Related Knowledges
  • Comparative Analysis of High-Voltage Load Switch Technologies
    A load switch is a type of switching device positioned between circuit breakers and disconnectors. It features a simple arc extinguishing device capable of interrupting rated load current and certain overload currents, but cannot interrupt short-circuit currents. Load switches can be classified into high-voltage and low-voltage types according to their operating voltage.Solid gas-producing high-voltage load switch: This type utilizes the energy from the breaking arc itself to cause gas-producing
    12/15/2025
  • Analysis of Faults and Solutions for 17.5kV Ring Main Units in Distribution Networks
    With the improvement of social productivity and people's quality of life, the demand for electricity is continuously increasing. To ensure the effectiveness of power grid system configuration, it is necessary to reasonably construct distribution networks based on actual conditions. However, during the operation of distribution network systems, 17.5kV ring main units play a very important role, so the impact caused by failures is extremely significant. At this point, it is essential to adopt reas
    12/11/2025
  • How to install a DTU on an N2 Insulation ring main unit?
    DTU (Distribution Terminal Unit), a substation terminal in distribution automation systems, is secondary equipment installed in switching stations, distribution rooms, N2 Insulation ring main units (RMUs), and box-type substations. It bridges primary equipment and the distribution automation master station. Older N2 Insulation RMUs without DTUs cannot communicate with the master station, failing to meet automation requirements. While replacing entire RMUs with new DTU-integrated models would sol
    12/11/2025
  • Design of a New 12kV Environmentally Friendly Gas-Insulated Ring Main Unit
    1. Specific Design1.1 Design ConceptState Grid Corporation of China actively promotes grid energy conservation and low-carbon development to achieve national carbon peak (2030) and neutrality (2060) goals. Environmentally friendly gas-insulated ring main units represent this trend. A new 12kV integrated environmentally friendly gas-insulated ring main unit was designed combining vacuum interrupter technology with three-position disconnectors and vacuum circuit breakers. The design utilized Solid
    12/11/2025
  • Integrated Intelligent Ring Main Units in 10kV Distribution Automation
    In the rational application of intelligent technologies, the integrated intelligent ring main unit in 10kV distribution automation construction is more conducive to improving the construction level of 10kV distribution automation and ensuring the stability of 10kV distribution automation construction.1 Research Background Integrated intelligent ring main unit.(1) The integrated intelligent ring main unit adopts more advanced technologies, including but not limited to network technology, communic
    12/10/2025
  • 35kV RMU Busbar Failure Due to Installation Errors Analysis
    This article introduces a case of 35kV ring main unit busbar insulation breakdown failure, analyzes the failure causes and proposes solutions [3], providing reference for the construction and operation of new energy power stations.1 Accident OverviewOn March 17, 2023, a photovoltaic desertification control project site reported a ground fault trip accident in the 35kV ring main unit [4]. The equipment manufacturer arranged a team of technical experts to rush to the site to investigate the cause
    12/10/2025