• 100 kVA Single Phase Pole Mounted Transformer
100 kVA Single Phase Pole Mounted Transformer
discuss personally
Model
DR11-100/10
Basic info
Brand Vziman
Model NO. 100 kva Single Phase Pole Mounted Transformer
Rated capacity 100kVA
Series Single Phase Pole Mounted Transformer
Product Detail

Product Overview

A professional distribution transformer manufacturer with 10 years of expertise, specializes in single-phase pole-mounted transformers for urban and rural power distribution. Designed for 11kV, 12.4kV, 13.2kV, 13.8kV, and 34.5kV input voltages, these transformers deliver outputs such as 240/480V and 120/240V, complying with IEEE C57, ANSI C57, and IEC 60076 standards.

Leading Technological Advantages

  • Enhanced Lightning Resistance: Unique winding technology minimizes surge damage.

  • Superior Mechanical Strength: Low magnetic leakage design with 45° full-oblique step-laminated iron core structure resists short circuits.

Shell & Construction

Precision Manufacturing:

  • Mitsubishi laser cutting and CNC punching ensure mm-level accuracy.

  • ABB robotic welding with laser detection achieves a 99.99998% leak-proof rate.

  • Durable Coating: Electrostatic spray paint offers 50+ years of corrosion resistance (100h salt spray test, hardness ≥0.4).

  • Fully Sealed Design: Cylindrical structure with self-sealing manual pressure relief valve (ANSI-compliant), NEMA-standard hanger brackets, and 30+ year maintenance-free operation.

Core Components

Iron Core

  • High-quality cold-rolled grain-oriented silicon steel sheets from Baowu Steel (China), with mineral oxide insulation.

  • Precision cutting and stacking reduce no-load current, losses, and noise.

Windings

  • Low Voltage: High-grade cable paper-wrapped wires.

  • High Voltage: Polyurethane enamelled round copper wires.

  • Interlayer insulation with dot-adhesive paper ensures coil stability and insulation resistance.

Premium Materials

  • Silicon steel sheets: Baowu Steel Group.

  • Oxygen-free copper: Chinese high-purity grade.

  • Transformer oil: CNPC Kunlun 25# premium oil.

Additional Features

  • High-strength polymer or porcelain low/high-voltage bushings.

  • Ring-type full-copper tinned terminals.

  • Integrated current-limiting fuses and arresters for surge protection.

Product parameters:

  • Capacity: 100kVA 

  • Rated voltage: 13.8kV, 34.5kV

  • Maximum operating voltage (kV) 38.5kV

  • Conditions of use:

  • The temperature:
    Maximum daily temperature (℃) : 40; Minimum daily temperature (℃) : -25; Maximum daily temperature difference (K) : 25; Average temperature of the hottest month (℃) : 30; Maximum annual average temperature (℃) : 20; Average daily relative humidity (≤%) : 95; Average monthly relative humidity (≤%) : 90 

  • Altitude (≤m) : 1000

  • Solar radiation intensity (W/cm2) : 0.1

  • Maximum ice thickness (mm) : 10

  • 10m high from the ground, maintain 10min average maximum wind speed (m/s) : 35

  • Ground horizontal acceleration (M/S2) : 2

  • Installation place: outdoor; 8. Pollution grade: ⅲ

image.png

Ordering instructions:

  • Main parameters of transformer (voltage, capacity, loss and other main parameters) .

  • Transformer use environment (altitude, temperature, humidity, place, etc) .

  • Other customized requirements (tap switch, color, oil pillow, etc) .

  • The minimum order quantity is 1 set, global delivery within 7 days .

  •  The normal delivery period is 30 days, with fast delivery worldwide .

What are the advantages of a single-phase pole-mounted transformer?

  • High Efficiency:Utilizes premium winding materials and advanced manufacturing techniques to achieve superior energy conversion efficiency, reducing operational losses.

  • Low Loss Performance:Constructed with high-grade silicon steel sheets and precision processes, minimizing no-load and load losses for enhanced energy savings and environmental friendliness.

  • Extended Service Life:Premium materials and rigorous manufacturing standards ensure prolonged durability, reducing replacement needs over the product lifecycle.

  • Low Noise Operation:Optimized core and coil design significantly reduces operational noise, making it ideal for noise-sensitive environments like urban areas or commercial buildings.

  • Reliable Performance:Oil-immersed design offers excellent cooling and insulation capabilities, ensuring stable operation in high-power, high-voltage applications.

  • Enhanced Fire Safety:Despite oil-based insulation, modern designs incorporate multi-layer protective measures (e.g., pressure relief valves, fire-retardant coatings) to mitigate risks.

  • Robust Environmental Adaptability:Engineered to withstand harsh conditions, including extreme temperatures, high humidity, and rugged terrain, for versatile deployment.

Know your supplier
Vziman
Zhejiang Vziman Electric Group Co., Ltd. is a high-tech enterprise specializing in R&D, manufacturing, and service of power electrical equipment. Committed to innovation, quality, and customer satisfaction, it supplies smart solutions for global power sectors, covering grid construction, new energy, and industrial distribution. Core Business • Switchgear (GIS, circuit breakers, Recloser, Load break switch) • Distribution equipment (transformers, RMU, smart terminals) • Power automation systems • Engineering services (installation, maintenance, consulting) Technical Strength • Provincial R&D center, multiple patents • Modern production, ISO/GB/IEC/CE/UL certified • High capacity, large-scale delivery support Market & Vision Serves State Grid, Southern Grid, and global projects (Asia, Africa, Europe, etc.). Aims to lead in smart grids and new energy, promoting sustainable energy development.
Main Categories
High voltage
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$150000000
Professional Experience
3 years
Workplace
10000m²
占位
占位
Related Products
Related Knowledges
Analysis of Partial Discharge Principle (1)
Analysis of Partial Discharge Principle (1)
Analysis of Partial Discharge Principle (1)Under the action of an electric field, in an insulation system, discharge occurs only in some regions and does not penetrate between the conductors with the applied voltage. This phenomenon is called partial discharge. If partial discharge occurs near a conductor surrounded by gas, it can also be called corona.Partial discharge can occur not only at the edge of a conductor but also on the surface or inside an insulator. The discharge occurring on the su
Leon
07/19/2025
What types of FACTS controllers are there?
What types of FACTS controllers are there?
According to the type of connection FACTS Controller with the power system, it is classified as;Series Connected ControllerShunt Connected ControllerCombined Series-Series ControllerCombined Shunt-Series ControllerSeries-Connected ControllersSeries controllers introduce a voltage in series with the line voltage, typically using capacitive or inductive impedance devices. Their primary function is to supply or absorb variable reactive power as needed.When a transmission line is heavily loaded, the
Edwiin
07/19/2025
What are FACTS and related technologies?
What are FACTS and related technologies?
FACTS (Flexible Alternating Current Transmission System) refers to a power electronics-based system that uses static devices to enhance the power transfer capability and controllability of AC transmission networks.These power electronic devices are integrated into conventional AC grids to boost key performance metrics, including:Power transfer capacity of transmission linesVoltage stability and transient stabilityVoltage regulation precisionSystem reliabilityThermal limits of transmission infras
Edwiin
07/19/2025
What are the differences between HVAC and HVDC?
What are the differences between HVAC and HVDC?
Difference Between HVAC and HVDCElectricity generated in power plants is transmitted over long distances to electrical substations, which then distribute it to consumers. The voltage used for long-distance power transmission is extremely high, and we will explore the reasons for this high voltage later. Additionally, the transmitted power can be in either alternating current (AC) or direct current (DC) form. Therefore, power can be transmitted using either HVAC (High Voltage Alternating Current)
Edwiin
07/19/2025
What are the Advantages of HVDC over HVAC?
What are the Advantages of HVDC over HVAC?
What are the Advantages of HVDC over HVAC?Electricity travels long distances before reaching consumers. Power plants, often remote, supply electricity through hundreds of miles and multiple substations. High-voltage transmission reduces line losses, with both AC and DC used. Though AC is familiar via utility poles and home outlets, HVDC offers unique advantages in power transmission.The goal of power transmission is to minimize losses and costs. While both face influencing factors, HVDC has more
Edwiin
07/19/2025
Is the neutral - point grounding method of the power grid of 110kV and above only the neutral - point direct grounding method?
Is the neutral - point grounding method of the power grid of 110kV and above only the neutral - point direct grounding method?
Neutral - Point Grounding Modes and Protection of Transformers in Power GridsFor systems ranging from 110 kV to 500 kV, an effective grounding method shall be adopted. Specifically, under all operating conditions, the ratio of zero - sequence reactance to positive - sequence reactance X0/X1 of the system should be a positive value and not exceed 3. Meanwhile, the ratio of zero - sequence resistance to positive - sequence reactance R0/X1should also be a positive value and not exceed 1.In 330 kV a
Leon
07/19/2025
×
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!