• Photovoltaic inverter grid-connected transformers
Photovoltaic inverter grid-connected transformers
discuss personally
Model
SGG/SD-60kVA
SGG/SD-80kVA
SGG/SD-100kVA
SGG/SD-25kVA
Basic info
Brand ROCKWILL
Model NO. Photovoltaic inverter grid-connected transformers
Rated frequency 50/60Hz
Rated capacity 60KVA
Series SGG
Product Detail

Product Overview

An isolated transformer is a double-winding transformer that not only achieves voltage transformation in the power grid but also provides electrical safety isolation between input and output windings. This feature effectively prevents electric shock hazards when the human body comes into simultaneous contact with live components (or metal parts that may become charged due to insulation damage) and the ground. Additionally, it can isolate the third harmonics in the power grid, reduce heat generation during equipment operation, and extend the service life of insulating materials. It also functions to suppress and eliminate interferences such as noise, clutter, high voltage, and surges in the power grid, providing a pure power environment for equipment.

The dry-type photovoltaic transformers produced by our company are special transformers designed for photovoltaic grid-connected inverters. Adopting a foil winding process, the transformer core features a full-joint structure, and the core laminations are made of low-loss oriented silicon steel sheets, offering significant advantages of low loss, high efficiency, and low temperature rise. This series of transformers is suitable for circuits with an AC frequency of 50Hz/60Hz and a rated voltage below 690V, and can be custom-designed and manufactured according to specific user requirements.

Product features

  • Energy-saving and low-noise:High-quality cold-rolled silicon steel sheets are used for stacking; The special dipping process is used to effectively reduce the vibration and noise during operation; As well as the introduction of new processes and technologies such as the design of high-temperature resistant insulation materials, the transformer is more energy-saving and quieter. The coil has a ventilation groove to allow for smooth air flow, effectively reducing the coil temperature.

  • High reliability:The structure is reasonable, the efficiency is high, the waveform is not distorted, it is convenient and reliable to use, it can run for a long time, and the performance indicators fully meet the standard requirements of GB/6450 dry-type power transformer. It can isolate the power supply of the main power grid, anti-shock, anti-interference, and anti-lightning.

  • Eco-friendly features:It has heat resistance, moisture resistance, stability, chemical compatibility, low temperature resistance, radiation resistance and non-toxicity.

  • Versatility:From a single transformer to a multi-functional combined transformer with air cooling, protective housing, transformer and so on.

Model specifications:

Note:The dimensions and technical indicators of the above products can be customized according to customer requirements.

Application scenarios:

SGG/SD series photovoltaic inverter grid-connected transformer is a supporting product of solar photovoltaic, its rated input voltage is AC three-phase 270V, rated output voltage is AC three-phase 400V, rated working frequency is 50/60HZ, it will be the direct current in the solar energy through the photovoltaic inverter inverter out of the three-phase AC 270V voltage isolation and step-up into three-phase AC 400V voltage, in order to be integrated into the grid or directly supply the single-phase 220V and three-phase 380V AC power supply required by users.

 

 

 

Know your supplier
ROCKWILL
Rockwill Electric Group Global Manufacturer of High voltage and medium-voltage power equipment and smart grid solutions. Headquartered in Wenzhou, China. Serving 100+ countries with quality, innovation, and trust. What We Offer: • HV-MV switchgear (VCB, SF₆ circuit breakers, RMU, GIS) • Distribution transformers and substations • Smart grid and monitoring systems • Solar, wind, EV charging, and energy storage solutions • EPC turnkey power projects Certified: ISO 9001 / ISO 14001 / ISO 45001
Main Categories
High voltage
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$150,000,000
Professional Experience
16 years
Workplace
108000m²m²
占位
占位
Related Products
Related Knowledges
Analysis of the Principle of Second - harmonic Restraint for Overcurrent Protection of Distribution Automation Switches
Analysis of the Principle of Second - harmonic Restraint for Overcurrent Protection of Distribution Automation Switches
Substance of Second - harmonic Restraint in Overcurrent ProtectionThe substance of second - harmonic restraint in overcurrent protection is to use the second - harmonic component to judge whether the current is a fault current or an excitation inrush current. When the percentage of the second - harmonic component to the fundamental - wave component is greater than a certain value, it is judged to be caused by the excitation inrush current, and the overcurrent protection is blocked.Therefore, the
Leon
07/18/2025
What are the common faults of low-voltage voltage transformers?
What are the common faults of low-voltage voltage transformers?
Open - Circuit Fault on the Secondary SideOpen - circuit in the secondary side is a typical fault of low - voltage voltage transformers, showing abnormal voltmeter readings (zero/fluctuation), faulty power meters, buzzing noises, and core overheating. When open - circuited, the secondary voltage spikes (no secondary current to balance the primary EMF), causing core saturation, flux distortion, and potential overheating/damage.Causes include loose terminals, poor contact, or human error. In low
Felix Spark
07/18/2025
What are the typical connection methods for 35kV distribution lines?
What are the typical connection methods for 35kV distribution lines?
Typical Wiring Diagram of 35kV Line Radial π ConnectionWhen a 35kV line adopts a radial power grid structure, a single - side power supply or a double - side power supply radial type can be used according to the situation of the power supply points, and a loop - out interval is reserved at the end of the line.Typical Wiring Diagram of 35kV Line Radial T - ConnectionFor double - radial lines, it is advisable to select a double - side power supply. When the power supply points do not meet the r
Leon
07/18/2025
Why are the ground fault point and the accident point not at the same location?
Why are the ground fault point and the accident point not at the same location?
Fault Transfer VoltageIn low - voltage distribution systems, there is a type of personal electric shock accident where the accident occurrence point and the system fault point are not at the same location. This kind of accident occurs because after a ground fault happens elsewhere, the generated fault voltage is conducted to the metal casings of other equipment through the PE wire or PEN wire. When the fault voltage on the metal casing of the equipment is higher than the human - body safe voltag
Leon
07/18/2025
Analysis of Transformer Capacity, Load Rate and Number of Units Selection Issues
Analysis of Transformer Capacity, Load Rate and Number of Units Selection Issues
The safe and economical operation of power transformers is related to the safety, economy, stability, and reliability of the operations of various industries. The limitations of conditions such as the investment economic indicators for its selection, the economic benefits of maintenance and operation, and the adaptability in the new environment (access of distributed power sources, configuration of energy storage, etc.) make it impossible to include comprehensive factors in other aspects.The cap
Leon
07/17/2025
Analysis of the Impact of Immersion on the Performance of Low-Voltage Current Transformers
Analysis of the Impact of Immersion on the Performance of Low-Voltage Current Transformers
1 IntroductionLow - voltage current transformers for metering, with a through - core type epoxy resin structure, are widely used in distribution transformer areas and for small - to - medium - sized industrial and commercial electricity consumption. As a range expander for electric energy metering, their performance directly relates to electricity consumption safety and the accuracy of users' trade calculations. Studying long - term immersion's impact on these transformers is practically signifi