Transformator distributivus siccativus ex aere silicio 10.5kV 630kVA/800kVA/1000kVA/1250kVA/1600kVA/2000kVA

  • 10.5kV Silicon Steel Dry Type Distribution Transformer 630kVA/800kVA/1000kVA/1250kVA /1600kVA/2000kVA
  • 10.5kV Silicon Steel Dry Type Distribution Transformer 630kVA/800kVA/1000kVA/1250kVA /1600kVA/2000kVA

Attributa principalia

Marca Vziman
Numerus Modeli Transformator distributivus siccativus ex aere silicio 10.5kV 630kVA/800kVA/1000kVA/1250kVA/1600kVA/2000kVA
Capacitas nominata 2000kVA
Gradus tensionis 10.5KV
Series SCB

Descriptiones productorum a fornitori

Descriptio

Characteristica:

  •  Nucleus magneticus habet iuncturam scalini lapidis ad optimam praestantiam et minima sonitus per technologiam scalini lapidis.

  •  Involucra sub vacuo cum resina epoxidi funduntur. Testes analysium transientium effecti sunt ad verificandum distributionem stressus electrici.

  • Systema refrigerationis aeris adoptat ventilatorem fluxus transversi superioris, qui characteribus sonitus minimi, pressionis venti altae, speciei pulchrae, etc., praeditus est.

  •  Regulator temperaturae intelligentis securitatem et fiduciam transformatoris augit.

  • Offert varias optiones Involucrorum in IP20, IP23, etc.


Parametri:

image.png


Locus Installationis:


  • Installatur in locis sine periculo incendi, explosionis, pollutionis gravis, corrosionis chemicae et vibrationis aggregatae, intra vel extra.

  • Potentia supply 500 Set/Sets per mensem.

Servitium Customizatum:

  • Classis Environmentalis E2

  • Classis Climatica C2

  • Classis Resistentiae Ignis F1


Advantagia Producti:

  •  Funditio Sub Vacuo

    Nostrum productum conficitur per processum funditionis sub vacuo utendo patrono metallico, producens stratum resinae crassum cum superficie laevi.

  •  Absque Discharge Partiali

  • Caracteristici partialis discharges minoris.

  • Omnia unita subjiciuntur testi partialis discharge.

  • Voltage quod duplex est systematis operativi applicatur ad securitatem assecurandam.

  • Partialis discharge minor quam 10 pC.

  •  Itemmata Testis Officinae

Testis Routine:

  • Testis routine est testis necessarius pro omnibus transformatoribus in nostra officina.

  • Testis typicus (si requiritur).

  • Testis impulsus fulminis.

  • Testis incrementi temperature.

  • Mensura sonitus.


Quomodo current in involucro primario creat magneticum alternans in nucleo?


Relatio inter Currentem et Magneticum Campum:

Cum current transcurrere per conductor, magneticum campum generabitur circa conductor. Pro transformatore, current in involucro primario generabit magneticum campum in nucleo ferreo. Passus specifici sunt sicut sequitur:

Current transcurrit per involucrum primarium:

  • Supply AC: Involucra primaria transformatoris conectuntur ad supply AC, et current ab supply AC provisus est alternans, id est, directio et magnitudo currentis periodiciter mutatur tempore.

  • Forma currentis: Assumendo formam currentis supply AC esse sinusoidalem, potest mathematica exprimi ut I(t)=I0sin(ωt)  ,ubiI0  est maximum valoris currentis,ω est frequentia angularis,t est tempus.

 Generatio magneticum campi:

  • Generatio magneticum campi: Cum current alternans transcurrere per involucrum primarium, magneticum campum generabitur circa involucrum. Secundum legem circuitalis Ampère, fortitudo magneticum campi 
    B  generata ab currente in circuito clauso proportionalis est currenti.

  • Directio magneticum campi: Directio magneticum campi potest determinari per regulam dextrae manus. Digito pollice dextrae manus indicare in directionem currentis, et directio qua quatuor digiti volvantur est directio magneticum campi.


Bibliotheca Documentorum Rerum
Restricted
Vziman IEC/ ANSI Dry-Type Power transformer selection catalog
Catalogue
English
Consulting
Consulting
Cognosce tui fornitori
Venditio Online
Ratio praestabilitae tradendae
Tempus responsionis
100.0%
≤4h
Brevis Descriptio Societatis
Locus Operis: 10000m² Numerus omnium laborantium: 300 Summa Annua Exportatio (USD): 150000000
Locus Operis: 10000m²
Numerus omnium laborantium: 300
Summa Annua Exportatio (USD): 150000000
Servitia
Genus Negotii: Design/Fabricatio/Venditio
Categorias Principales: apparatus electrum altum voltus/transformator
Gubernatio vitae
Servitia gestionis curae integralis pro quaestu, usu, conservatione et post-venditionem apparatus electricorum, securitatem operationis, continuationem imperii et usum electricitatis sine cura garantia.
Fornitori instrumentorum praeteritus est certificationem qualificationis platformae et iudicium technicum, ut ex fonte conformitas, professionalitas et fiducia servantur.

Producta Connexa

Cognitio Connexa

  • Accidentia Transformatoris Principalis et Questiones Operationis Gas Luminis
    1. Registri accidentis (XIX Martii, MMXIX)Hora XVI:XIIX die XIX Martii, MMXIX, monitorium background reportavit actionem gas levis transformatoris principis numeri III. Conformiter Codex Operationis Transformatorum Electricitatis (DL/T572-2010), personale operationis et maintenance (O&M) inspectavit statum in situ transformatoris principis numeri III.Confirmatio in situ: Panel non-electricus protectionis WBH transformatoris principis numeri III reportavit actionem gas levis phase B corpus tr
    02/05/2026
  • Culpae et Tractatio Terrae Unipolaris in Lineis Distributionis 10kV
    Characteristica et Instrumenta Detegendi Defectus Terrae Monofasiales1. Characteristica Defectuum Terrae MonofasialiumSigna Centralia Admonitionis:Campanula admonitionis sonat, et lucerna indicativa inscripta „Defectus Terrae in Sectione Omnibus [X] kV [Y]“ accenditur. In systematibus ubi punctum neutrum per bobinam Petersen (bobinam suppressionis arcus) ad terram connectitur, lucerna indicativa „Bobina Petersen Operatur“ etiam accenditur.Indicationes Voltmetri Monitoris Isolationis:Tensio phase
    01/30/2026
  • Modus operationis terre iunctae puncti neutralis pro transformatoribus retis electricitatis 110kV~220kV
    Dispositio modi operis terrae puncti neutralis pro transformatoribus rete electricitatis 110kV~220kV debet exigentias tolerationis insulationis puncti neutralis transformatorum complere, et simul conari ut impedimentum sequentiae nullae stationum transformationis fere immutatum maneat, dum certatur ne impedimentum sequentiae nullae compositum in quocumque puncto raptus circuiti systematis ultra ter impedimentum sequentiae positivae compositum excedat.Pro transformatoribus 220kV et 110kV in novis
    01/29/2026
  • Cur Quare Substationes Lapidem Gravem Calculos et Rupem Fractam Utuntur
    Cur Quare Substationes Utuntur Lapidibus, Gravibus, Piscinis et Saxis Tritis?In stationibus transformationis, instrumenta ut transformatores electricitatis et distributionis, lineae transmissionis, transformatores tensionis, transformatores currentis et commutatores disiunctionis omnia terram exigunt. Praeter terram, nunc profundius explorabimus cur gravia et saxa trita in stationibus transformationis saepe utuntur. Quamquam videantur ordinaria, isti lapides partem criticam iuxtaque functionalem
    01/29/2026
  • Cur autem nucleus transformatoris tantum in uno puncto terram tangere debet Nonne terra multipuncta fidelius est
    Cur ergo nucleus transformatoris terram tangere debet?In operatione, nucleus transformatoris, simul cum structuris, partibus et componentibus metallicis quae fixant nucleum et spiras, in forti campo electrico situs est. Sub influentia huius campi electrici, potentialem relativum altum ad terram comparatum acquirunt. Si nucleus non terra tangitur, differentia potentialis inter nucleum et structuras claudicantes et vas terratum existet, quae possit ad intermitterentiam dismissionem ducere.Praetere
    01/29/2026
  • Intellegere Terram Neutralis Transformatoris
    I. Quid est Punctum Neutrum?In transformatoribus et generatoribus, punctum neutrum est locus specificus in spira ubi absoluta tensio inter hunc locum et singula terminalia externa aequalis est. In diagrammate infra, punctumOrepraesentat punctum neutrum.II. Cur Punctum Neutrum Terrendum Est?Modus connexionis electricae inter punctum neutrum et terram in systemate AC triphasico diciturmodus terrendi puncti neutri. Hic modus directe afficit:Securitatem, fidem et oeconomiciam retelectrici;Selectione
    01/29/2026

Solutiones Relatae

Instrumenta Libera Cognata
Non invenisti adhuc opportunos fornitoris ut te inveniant Citationem Nunc Accipe
Non invenisti adhuc opportunos fornitoris ut te inveniant
Citationem Nunc Accipe
Inquiry
+86
Click to upload file
Descarica
Obtine Applicatio Commerciale IEE-Business
Utiliza app IEE-Business ad inveniendum apparatus obtinendumque solutiones coniungendum cum peritis et participandum in collaboratione industriale ubique et semper propter totam supportionem tuorum projectorum electricitatis et negotiorum