Ladle refining furnace transformer(distribution transformer)

  • Ladle refining furnace transformer(distribution transformer)

Key attributes

Brand Vziman
Model NO. Ladle refining furnace transformer
Rated capacity 20000kVA
Series Ladle refining furnace transformer
Description

Description
The ladle refining furnace (LF furnace) transformer is a core equipment in the iron and steel smelting industry, primarily used to provide stable electric energy for the molten steel refining process. Its performance directly impacts the efficiency, energy consumption, and safety of steel production. With the development of electric furnace steelmaking technology, especially the popularization of large-scale LF furnaces above 40 tons, the design and technical standards of transformers have gradually shifted towards high efficiency and internationalization, forming a technological trend centered on energy conservation, reliability, and low maintenance.

Key Features

Energy Efficiency: Low no-load/load losses, optimized impedance voltage; uses Baowu/Nippon Steel 30Z130/30Q130 silicon steel. 

Reliability: 30+ year design life; fully oblique core joints, German Georg shear (<0.02mm burr), low-magnetic steel clamping. 

Overload Capability: Stable operation at 120% load via oxygen-free copper windings, small oil gaps, and cooling cylinder structures. Low Maintenance: 10+ years maintenance-free; vacuum oil injection, anti-aging seals, and folded plate tanks prevent leaks.

Components

Core

  • Material: Uses Baowu 30Z130 or Nippon Steel 30Q130 silicon steel, matching materials used in developed countries.

  • Structure: Full oblique-joint lamination design with low-magnetic steel plate pull rods for clamping, eliminating punching holes to ensure uniform magnetic flux density across core sections without distortion.

  • Processing: German Georg shearing line controls burrs ≤0.02mm (standard ≤0.05mm) and length tolerance ≤0.2mm/m, improving lamination factor to reduce local overheating, noise, and no-load losses.

Windings

  • Material: Oxygen-free copper magnet wires (P<0.017241 at 20°C) with precise insulation paper wrapping.

  • Design: Small oil gaps, internal/external oil baffles, and cooling cylinder structure enhance axial/radial stability, overload capacity, and reduce losses.

  • High-Voltage Solutions: "8"-type coils for one-time winding in high-load voltage regulation and 110kV-grade products, improving strength and reducing eddy current losses.

Body

  • Structure: Laminated wood for all wooden parts to enhance lead frame rigidity; upper/lower pressboards made of insulation boards or epoxy molded parts to increase conductor-to-ground insulation distance and reduce "window height" dimensions.

  • Insulation: Imported cardboard for main insulation, multi-coil integral assembly, and Norwegian steam drying equipment to ensure thorough drying without damaging insulation.

Oil Tank

  • Design: Folded plate structure minimizes welds, tested for positive/negative pressure to ensure sealing reliability.

  • Loss Reduction: Low-magnetic steel or magnetic shielding in strategic positions reduces additional losses from busbar magnetic fields on the tank wall, effectively preventing leakage and reducing losses.

Assembly

  • Process: Hydraulic compaction after body drying and vacuum oil injection to eliminate winding bubbles and reduce partial discharge.

  • Sealing: Anti-aging sealing materials address oil leakage; control circuits (gas relay, thermometers, etc.) integrated into a top-mounted junction box for a sleek, unified appearance.

Accessories

  • Cooling: YS1 water-coolers or stainless steel spiral plate coolers; anti-pollution high-voltage bushings increase creepage distance.

  • Tap Changers: Advanced "M" or "V" type from leading manufacturers with remote display and control interfaces.

  • Oil System: Karamay naphthenic anti-aging transformer oil in fully enclosed tanks with pressure relief valves and diaphragm conservators for complete protection.

Transformer Maintenance and Technical Assurance Summary

For transformer maintenance, long-distance transported core-hanging products require post-arrival checks to address loose fasteners and facilitate user acceptance, while routine overhauls should focus on replacing mechanical wear parts (e.g., pumps) per the original cycle. Quality assurance includes designing windings with a 20% overload margin (e.g., 24000kVA for a 20000kVA-rated LF furnace transformer) to ensure stable operation at 120% load, with impedance voltage ≤8% and heat load calculations based on the higher capacity. Anti-impact and short-circuit measures enhance coil axial/radial stability via high-voltage-grade wires, precise drying, hydraulic compaction, and multi-support structures. To guarantee 20-year maintenance-free operation, the design uses Karamay naphthenic oil in fully enclosed tanks with diaphragm conservators, anti-aging seals, and regular oil chromatographic analysis. Key improvements include Baowu/Nippon Steel silicon steel cores with ultra-low burr shearing, oxygen-free copper windings with small oil gaps, laminated wood bodies, folded-plate tanks with magnetic shielding, and integrated control systems. Future trends for ore-heating furnaces include single-phase transformers with side-mounted water-cooling for ≥15000kVA models, while maintenance prioritizes non-intrusive monitoring via oil analysis to reduce costs and contamination risks.

Know your supplier

Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 10000m² Total staff: 300 Highest Annual Export(usD): 150000000
Services
Business Type: Design/Manufacture/Sales
Main Categories: High Voltage Electrical Apparatus/Electric transformer
Related Products
Related Knowledges
  • How has g3 technology changed the global climate?
    The Alternative to SF6 for High Voltage ApplicationsRemoving Greenhouse Gases from the GridNineteen of the warmest years on record have occurred since 2000, where greenhouse gases (GHGs) are at the root cause of climate change. Sulfur hexafluoride (SF₆), an insulating gas used in high-voltage switchgear, is estimated to contribute 23,500 times more than carbon dioxide (CO₂) to the greenhouse effect and can remain in the atmosphere for 3,200 years. Previously, Power Generation and Transmission ut
    05/09/2026
  • Difference Between Maintenance Earthing Switches and Fast Earthing Switches?
    Maintenance earthing switches and fast earthing switches (FES) are two types of switches with distinct characteristics.Maintenance Earthing SwitchesThese are typically configured alongside the disconnectors on both sides of a circuit breaker. Their sole purpose is to provide safety grounding on both sides of the circuit breaker during equipment maintenance.Fast Earthing Switches (FES)These are positioned on the line side of the outgoing disconnector in an outgoing circuit. They serve two primary
    05/08/2026
  • SiC MOSFET Solid State Circuit Breakers for Low Voltage Protection
    1. Core Principle SummaryIn simple terms, its core principle can be summarized as a three-step AC-DC-AC conversion, with the key step being to increase the frequency first, then transform the voltage.2. Working PrincipleRectification:First, the input line-frequency AC power (e.g., 50 Hz or 60 Hz) is rectified into DC power using power electronic devices (such as IGBTs). This step converts low-frequency AC into stable DC, preparing it for subsequent processing.High-Frequency Chopping (Inversion):
    05/03/2026
  • Solid-State Circuit Breakers Set to Revolutionize Circuit Protection
    Custom modules built with SiC MOSFETs minimize the impacts of short circuits and overloadsNearly every electrical engineer has wondered at some point whether it is possible to design a non-mechanical circuit breaker. There are plenty of reasons for this line of thought: would it not be better to use semiconductors to interrupt faults or handle overload conditions?However, deeper investigation inevitably reveals major obstacles. For one thing, the breakdown voltage of familiar power devices is ar
    05/03/2026
  • 2025 Complete Guide to Solar Cell Selection-Scenario Adaptation
    Solar Panel – Comprehensive Guide to Solar Cell SelectionA systematic selection reference for photovoltaic engineers and technicians, covering technical principles, key parameters, application scenarios and development trends.Data baseline: 2024–2025 industrial mass-production levels (CPIA data)1. The Role of Solar Cells in Photovoltaic SystemsMore than 90% of the conversion efficiency and power generation performance of PV modules are determined by solar cells. As the core semicondu
    05/03/2026
  • Technological Evolution of Silicon Carbide (SiC) Based DC Solid-State Circuit Breakers
    1. Introduction: Protection Challenges in the DC Distribution EraAs the global energy transition accelerates, DC microgrids, high-voltage DC (HVDC) power supplies for data centers, and large-scale energy storage systems have become critical components of power systems. However, DC systems lack a natural zero-crossing point and possess extremely low system impedance, leading to a rapid rate of rise of fault current (di/dt). Traditional mechanical circuit breakers, limited by millisecond-level ope
    04/25/2026
Related Free tools
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.