1.65 to 20kV 50/60HZ engineering MV voltage regulation frequency converter

  • 1.65 to 20kV 50/60HZ engineering MV voltage regulation frequency converter
  • 1.65 to 20kV 50/60HZ engineering MV voltage regulation frequency converter

Key attributes

Brand Rw Energy
Model NO. 1.65 to 20kV 50/60HZ engineering MV voltage regulation frequency converter
Rated frequency 50/60Hz
Series HD8000

Product descriptions from the supplier

Description

Overview

1.65kV、2.4kV、3.3kV、4.16kV、6.6kV、10kV、13.8kV、19.8kV; 8MVA~102MVA (stand-alone), which can support up to eight machines in parallel.

Performance characteristics

Engineered reliability design

  • IGCT fault and judgment + bridge arm pass-through protection technology

  • Redundancy design and fault tolerance designof key components

  • IP54 protection design, C4-M anti-corrosion design

  • Double-sided crimped structure power devices

Modular design

  • Modular design of key components

  • Intelligent fault diagnosis system for quick positioning

  • Phase module disassembly time only takes 15 minutes, making maintenance simple and fast

Excellent control

  • Four-quadrant operation to meet the electric and brake energy feedback

  • Adaptable to asynchronous induction motor, permanent magnet synchronous motor and electric excitation synchronous motor

  • Fast torque dynamic response and torsional vibration suppressionfunction

  • Segmented synchronous modulation of the motor to meet the requirements of high speed regulation range such as steel rolling and hoist

  • SHEPWM (specific harmonic cancellation pulse width modulation)

Adaptable

  • Single-motor transmission configuration/multi-motor transmission configuration

  • High-altitude design: no derating required for use within 2000m

  • Grid adaptability design: The system has the ability to adapt to grid imbalance, power grid harmonics, grid frequency flicker, grid transient drop, and high and low voltage cross-ride.

Communication Protocols & Smart Software

  • Customizable communication protocol

  • Powerful monitoring system can monitor internal data, waveforms, etc. in real time

  • Provide fast debugging tool hopeInsight for quick network debugging

International leading level technology

  • "High-power IGCT AC and Orthogonal Frequency Conversion Speed Regulation Device" and "Key Technologies and Applications of High-Power IGCT AC Orthogonal Frequency Conversion Speed Regulation System" have been identified as international advanced level, and a number of technologies have been identified as international leading level

Main parameters

project

Specifications and technical data

Basic rectification

Input frequency

45Hz~66Hz

Fundamental power factor

≤ 95% (based on 12 pulses and above, rated current, equipped with 2% current input reactor)

PWM rectification

Input frequency

45Hz~66Hz

Factor

1 (Continuously settable)

Protection function

Overload protection, overheat protection, short circuit protection, fault prediction, etc

Inverse

Output voltage

1:1.65kV,2:2.4kV,3:3.3kV, 4:4.16kV,6:6.6kV,

A:10kV,B:13.8kV,C:19.8kV

Output frequency

0~110Hz (higher output frequency can be customized according to requirements)

Steady speed accuracy

OLVC:0.2% ; CLVC:0.01%

Pulsating speed

OLVC:0.4% ; CLVC:0.2%

Start torque

OLVC:150%; CLVC:200%   

Torque control

V/F: Support ; OLVC: Support; CLVC: Yes

Torque accuracy

OLVC:5% ; CLVC: 2% (customizable)

Torque response time

≤ 5ms

RPM response time

OLVC:100ms ;  CLVC:100ms

Dynamic drop equivalent

OLVC:0.5%*s ;  CLVC:0.25%*s

Machine

efficiency

Second quadrant: ≥99% (excluding rectifier transformer)

Quadrant 4: ≥ 98.5% (excluding rectifier transformer)

temperature

Inlet water temperature ≤35°C (outside water)

elevation

≤2000m (2000m~4000m reduced use)

Protection level

IP54

Cooling method

Water

Anti-corrosion grade

C4-M

 

Documentation Resource Library
Restricted
Medium-Voltage Engineering Variable Frequency Drive System catalog
Catalogue
English
Consulting
Consulting
FAQ for
Q: Can it be integrated with the old system?
A:

Supports protocols such as Profibus DP, Profinet, Modbus, etc. The factory's existing system can be directly connected without major modifications. Quick deployment, saving time and costs, and easy upgrade.

Q: Can the fluctuation of the power grid withstand it?
A:

Grid adaptive design can cope with power grid imbalance, harmonics, and frequency fluctuations. Automatically adjust during power grid fluctuations without tripping, ensuring continuous operation of equipment. Factory production is not affected and has higher efficiency.

Q: Is high voltage safe?
A:

IP54 protection, C4-M anti-corrosion design. Redundant design of key components, fault diagnosis+bridge arm penetration protection, safe and reliable. High voltage equipment safety comes first, and this is done particularly well, making operation more reassuring.
Can the fluctuation of the power grid withstand it?

Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 30000m² Total staff: Highest Annual Export(usD): 100000000
Workplace: 30000m²
Total staff:
Highest Annual Export(usD): 100000000
Services
Business Type: Design/Manufacture/Sales
Main Categories: High Voltage Electrical Apparatus/Low Voltage Electrical Apparatus/Instrument meters/New energy/Tester/Robot
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • Faults and Handling of Single-phase Grounding in 10kV Distribution Lines
    Characteristics and Detection Devices for Single-Phase Ground Faults1. Characteristics of Single-Phase Ground FaultsCentral Alarm Signals:The warning bell rings, and the indicator lamp labeled “Ground Fault on [X] kV Bus Section [Y]” illuminates. In systems with a Petersen coil (arc suppression coil) grounding the neutral point, the “Petersen Coil Operated” indicator also lights up.Insulation Monitoring Voltmeter Indications:The voltage of the faulted phase decreases (in
    01/30/2026
  • Distribution Equipment Transformer Testing, Inspection, and Maintenance
    1.Transformer Maintenance and Inspection Open the low-voltage (LV) circuit breaker of the transformer under maintenance, remove the control power fuse, and hang a “Do Not Close” warning sign on the switch handle. Open the high-voltage (HV) circuit breaker of the transformer under maintenance, close the grounding switch, fully discharge the transformer, lock the HV switchgear, and hang a “Do Not Close” warning sign on the switch handle. For dry-type transformer maintenance: first clean the porcel
    12/25/2025
  • How to Test Insulation Resistance of Distribution Transformers
    In practical work, insulation resistance of distribution transformers is generally measured twice: the insulation resistance between thehigh-voltage (HV) windingand thelow-voltage (LV) winding plus the transformer tank, and the insulation resistance between theLV windingand theHV winding plus the transformer tank.If both measurements yield acceptable values, it indicates that the insulation among the HV winding, LV winding, and transformer tank is qualified. If either measurement fails, pairwise
    12/25/2025
  • Design Principles for Pole-Mounted Distribution Transformers
    Design Principles for Pole-Mounted Distribution Transformers(1) Location and Layout PrinciplesPole-mounted transformer platforms should be located near the load center or close to critical loads, following the principle of “small capacity, multiple locations” to facilitate equipment replacement and maintenance. For residential power supply, three-phase transformers may be installed nearby based on current demand and future growth projections.(2) Capacity Selection for Three-Phase Pole-Mounted Tr
    12/25/2025
  • Risk Identification and Control Measures for Distribution Transformer Replacement Work
    1.Electric Shock Risk Prevention and ControlAccording to typical design standards for distribution network upgrades, the distance between the transformer’s drop-out fuse and the high-voltage terminal is 1.5 meters. If a crane is used for replacement, it is often impossible to maintain the required minimum safety clearance of 2 meters between the crane boom, lifting gear, slings, wire ropes, and the 10 kV live parts, posing a severe risk of electric shock.Control Measures:Measure 1:De-energize th
    12/25/2025
  • Analysis of Common Faults and Causes in Routine Inspection of Distribution Transformers
    Common Faults and Causes in Routine Inspection of Distribution TransformersAs the terminal component of power transmission and distribution systems, distribution transformers play a critical role in supplying reliable electricity to end users. However, many users have limited knowledge of power equipment, and routine maintenance is often carried out without professional support. If any of the following conditions are observed during transformer operation, immediate action should be taken: Excess
    12/24/2025
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.