| 브랜드 | ROCKWILL |
| 시리즈 | RCW |
Description:
Pioneer in China’s recloser industry and the first source manufacturer dedicated to this field — this is our identity forged by decades of deep cultivation. Over the past decades, we have consolidated our development foundation through technological breakthroughs, led the industry direction by formulating standards, and successfully built a fully independent system covering core technology R&D, large-scale mass production and delivery.
The RCW series automatic circuit reclosers are designed for use in overhead distribution lines and distribution substations. They are compatible with power systems operating at 50/60Hz, covering voltage classes from 11kV to 38kV. With a rated current capacity of up to 1250A, these reclosers integrate multiple functions, including control, protection, measurement, communication, fault detection, and real - time monitoring of closing and opening operations. Composed of an integration terminal, current transformer, permanent magnetic actuator, and a dedicated recloser controller, the RCW series vacuum reclosers offer a comprehensive solution for power distribution network management.
Features:
Flexible Current Ratings: Optional ratings within the rated current range to suit diverse application needs.
Customizable Protection: A variety of optional relay protection and logic schemes for users to choose from, ensuring adaptability to different system requirements.
Versatile Communication: Optional communication protocols and I/O ports available, enabling seamless integration with various monitoring and control systems.
User - Friendly Software: Equipped with PC software that supports controller testing, setup, programming, and updates, simplifying operation and maintenance.
Parameters:
The voltage classes of some of these Automatic Reclosers include 6kV, 6.3kV, 6.6kV, 6.9kV, 7.2kV, 10kV, 10.5kV, 11kV, 11.5kV, 12kV, 13.2kV, 13.8kV, 14.5kV, 14.4kV, 15kV, 15.5kV, 15.6kV, 17.5kV, 20kV, 21.9kV, 22kV, 24kV, 30kV, 33kV, 33.5kV, 34.5kV, 35kV, 36kV, 38kV, 38.5kV, 40.5kV, 44kV, 45kV, 46kV, 66kV and 69kV. Rated Short-Circuit Breaking Current includes 8kA, 12.5kA, 16kA, 20kA, 25kA, 31.5kA and customization is available.
Item |
Specification |
Rated maximum voltage |
27kV |
Rated maximum current |
1250A |
Rated frequency |
50Hz |
Rated short circuit breaking current |
12.5kA |
Rated peak value withstand current |
31.5kA |
Rated 1min power frequency withstand voltage (Three-phase Silicone rubber pole (unable the gas)) |
70kV |
Rated lightning impulse voltage (Three-phase Silicone rubber pole (unable the gas)) |
150kV |
Operation sequence |
C-0.5-CO-2-CO-5-CO (Magnetic actuator) |
Mechanical life |
n:30000 (Magnetic actuator) |
Power supply and operating voltage |
110/220V (Customized) |
Ratio of current transformer |
400/1A (Customized) |
Number of voltage sensors (Three-phase Silicone rubber pole (unable the gas)) |
≤3 |
Opening time |
≤30ms (Magnetic actuator) |
Closing time |
≤40ms (Magnetic actuator) |
Minimum creepage distance |
31, level4 (mm/kV) |
Minimum distance between phases |
380mm |
Potential transformer |
110/220V (Customized) |
Cable length |
6,8,12m (Customized) |
Cable clamp (Three-phase Silicone rubber pole (unable the gas)) |
2-hole NEMA |
Lightning arrester |
≤6 |
Mounting type |
Single / double column |
With optional relay protection & logics for user choice |
Instantaneous over-current protection Timing over-current protection Negative sequence over-current protection Directional over-current protection(⁽¹⁾) Over-voltage protection / Under voltage protection Programmable protection relay curves (total 10 nos ANSI/IEC curves) Cold load pickup protection TCC + Hot line tag Earth protection E/F SEF + Zone- Sequence Co-ordination More relay functions can be customized |
With optional communication protocols & I/O port for user choice |
RS-232 and RS-485 ports supporting DNP3.0 communication protocol support Modbus communication protocol is optional IEC 60870-501 communication protocol support IEC 60870-5-104 communication protocol support The recloser can communicate through GPRS(or) GSM(or) GPRS/GSM module with English or Specified language |
With optional functions for use |
Rated currents, System phase current, Rated voltages, System phase voltage and secondary low voltage power supply voltage Frequency power (kWh), reactive power (kVarh), power factor |
With optional reclosing interval for user pre-program |
reclosing times setting support Dead time setting support |
With events recording function |
SOE 10000 operations record Fault record and normal operation record Note:mean should customized by manufacturer if needed |
External dimensions:

Environmental requirement:
Maximum temperature: |
+40°C |
Minimum temperature: |
-30°C |
Monthly average humidity |
95% |
Humidity: |
90% |
Above sea level: |
2500m or higher |
Ambient air Not apparently polluted by corrosive and flammable gas, vapor |
What are the key points for the selection of outdoor vacuum reclosers?
System Parameter Matching: Choose a recloser that matches the rated voltage, rated current, and short-circuit current levels of the power system. Ensure that the rated voltage of the recloser is equal to or higher than the system voltage, the rated current meets the requirements of the line load current, and the rated short-circuit breaking and making currents are greater than the maximum possible short-circuit current in the system.
Reclosing Performance Requirements: Consider the specific requirements of the power system for the reclosing function, such as the number of reclosures, reclosing time intervals, and reclosing success rate. Based on different application scenarios and power supply reliability requirements, select a recloser with appropriate reclosing performance. For example, for critical power supply lines, a recloser with a higher number of reclosures and flexible reclosing time intervals may be required.
Type of Operating Mechanism: Choose an appropriate operating mechanism based on actual needs. Spring-operated mechanisms are suitable for outdoor environments where high reliability is required and maintenance conditions are relatively poor. Permanent magnet-operated mechanisms are better suited for applications requiring high action speed and frequent operations.
Environmental Adaptability: Given the harsh conditions of outdoor environments, consider the environmental adaptability of the recloser. This includes weather resistance, pollution resistance, and water and dustproof performance. Selecting a recloser with good environmental adaptability ensures stable performance during long-term outdoor operation.
Brand and Quality: Choose well-known brands and high-quality recloser products. These products have strict quality control systems in design, manufacturing, and testing, ensuring the performance and reliability of the product. Additionally, good after-sales service is an important factor to consider when choosing a brand, as it ensures timely resolution of issues that may arise during equipment operation.
네. RCWP 구성은 RCW+ 제품군 내에서 비용 최적화된 옵션을 제공합니다. 이는 듀얼 센서(전압 + 전류), 플래그십 컨트롤러, 그리고 영구자석 작동 메커니즘 으로 구동되는 3상 연동 30,000회의 기계적 작동을 포함하고 있습니다.
더 저렴한 가격대를 달성하기 위해 다음의 다운그레이드 옵션이 가능합니다:
이로써 고객들은 적합하고 신뢰할 수 있는 기본 플랫폼부터 시작하여 실제로 필요한 기능에 대해서만 지불할 수 있습니다.
예 Rockwill은 RCW 시리즈를 지원하며 재폐합기 산업에서 가장 포괄적인 보증 중 하나를 제공합니다:
요약: 대부분의 국제 분배 자동화 애플리케이션에서 ZW32형 VCB를 직접 재폐락기로 대체할 수 없습니다. RCW 시리즈는 현대 스마트 그리드 배포에 필요한 보호 로직, 센서 통합 및 제어 지능을 제공합니다.