Dual Fuzzy-Sugeno Method to Enhance Power Quality Performance Using a Single-Phase Dual UPQC-Dual PV Without DC-Link Capacitor

IEEE Xplore
Field: Electrical Standards
0
Canada

This paper proposes a novel configuration of a dual UPQC supplied by a dual photovoltaic (PV), hereinafter referred to as 2UPQC-2PV, to improve the power quality performance of a single-phase 220 V/50 Hz distribution system. The 2UPQC-2PV configuration is proposed to anticipate the possible failure of both inverters in one of the UPQC circuits. The PV array replaces the DC-link capacitor to maintain its voltage connected to the DC-link of the UPQC constant while at the same time supplying active power to the load during an interruption voltage. The dual-fuzzy Sugeno (dual-FS) method is used to overcome the weakness of the dual-proportional-integral (dual-PI) control in determining the optimum parameters of proportional and integral constants.

1.Introduction

Many papers have discussed the deployment of dual UPQC circuits and control to enhance the power quality of supply and load of the low-voltage distribution network.The sinusoidal reference synchronization theory was used to build a straightforward UPQC control approach in the ABC reference frame in, whereas in, two distinct controls were compared to produce a pulse width modulation (PWM) reference signal using the α−β and d-q reference frames, respectively.   There have already been simulations, and lab tests comparing the operating performance of single UPQC and dual UPQC in a three-phase three-wire (3P3W) system under static and dynamic faults as well as providing additional adjustment to the grid voltage. Dual UPQC was able to produce better static and dynamic performance than single UPQC, according to the simulation and experimental data.

2. Research Method

    In this study, the single-phase Se-AF circuit consists of four MOSFET switches (MO1, MO2, MO3 and MO4) which inject a compensating voltage to the load bus when a sag/swell occurs on the source bus. The single-phase Sh-AF circuit consists of four IGBT switches (IG1, IG2, IG3 and IG4) that inject harmonic compensation current to the source bus because of the presence of nonlinear load (NL). In the proposed model, the NL is a full-bridge rectifier with diodes (D1, D2, D3 and D4) connected to a RL DC load.

The two proposed power electronics devices are the 1UPQC-1PV array and the 2UPQC-2PV arrays. To overcome the shortcomings of the 1UPQC-1PV system and maintain the magnitude of the load voltage while simultaneously reducing the load voltage THD and providing the load bus with a more stable active power supply in the event of voltage interruption on the source bus, the 2UPQC-2PV system is proposed. The suggested UPQC circuit does not include a DC-link capacitor, in contrast to other studies. 

Research flowchart.png

3. Result and Discussion

By using Matlab Simulink, each model combination is executed according to the proposed case to obtain the waveforms of the source voltage (VS), series voltage (VSE), load voltage (VL), source current (IS), shunt current (ISH), and load current (IL). Based on the waveforms, their magnitudes and corresponding THDs are obtained. The measurement of the magnitude of the voltage, nominal current, and THD values in each UPQC-PV combination was carried out in 3 cycles between 0.22 s-0.28 s. The next process performs simulations on a number of proposed cases to obtain curves and determine the values of PV voltage (VPV), PV current (IPV), and PV power (PPV), and their contribution to changes in load active power (PL), which are carried out in one cycle at 0.25 s. The PV power value is measured after the DC-DC boost converter circuit so its value is the same as the DC-link power because the UPQC circuit does not use capacitors. 

Proposed research of single-phase 2UPQC-2PV without dc-link capacitors using FS compared with previous research.png

4.Conclusion

The 2UPQC-2PV configuration to improve power quality performance in a single-phase 220 V / 50 Hzdistribution system has been implemented together with the 1UPQC-1PV configuration. The 2UPQC-2PV configuration is proposed to anticipate the failure of the two inverters in one of the UPQC circuits. The proposed model does not use a DC-link capacitor whose role is replaced by a PV generator to keep the UPQC DC voltage constant, while at the same time supplying power to the load during interruptions. The dual-FS method is used to overcome the weakness of the dual-PI control in determining the optimum parameters of proportional and integral constants. Disturbance simulations are carried out for the 2UPQC-2PV and 1UPQC-1PV configurations using dual-FS and dual-PI controls, and three cases, i.e., Case 1 (S-Sag-NL), Case 2 (S-Swell-NL), Case 3 (S-Inter-NL).

Source: IEEE Xplore
Statement: Respect the original, good articles worth sharing, if there is infringement please contact delete.



Give a tip and encourage the author!

Recommended

Impact of DC Bias in Transformers at Renewable Energy Stations Near UHVDC Grounding Electrodes
Impact of DC Bias in Transformers at Renewable Energy Stations Near UHVDC Grounding ElectrodesWhen the grounding electrode of an Ultra-High-Voltage Direct Current (UHVDC) transmission system is located close to a renewable energy power station, the return current flowing through the earth can cause a rise in ground potential around the electrode area. This ground potential rise leads to a shift in the neutral-point potential of nearby power transformers, inducing DC bias (or DC offset) in their
01/15/2026
How to Test Insulation Resistance of Distribution Transformers
In practical work, insulation resistance of distribution transformers is generally measured twice: the insulation resistance between thehigh-voltage (HV) windingand thelow-voltage (LV) winding plus the transformer tank, and the insulation resistance between theLV windingand theHV winding plus the transformer tank.If both measurements yield acceptable values, it indicates that the insulation among the HV winding, LV winding, and transformer tank is qualified. If either measurement fails, pairwise
12/25/2025
Design Principles for Pole-Mounted Distribution Transformers
Design Principles for Pole-Mounted Distribution Transformers(1) Location and Layout PrinciplesPole-mounted transformer platforms should be located near the load center or close to critical loads, following the principle of “small capacity, multiple locations” to facilitate equipment replacement and maintenance. For residential power supply, three-phase transformers may be installed nearby based on current demand and future growth projections.(2) Capacity Selection for Three-Phase Pole-Mounted Tr
12/25/2025
Analysis of Common Faults and Causes in Routine Inspection of Distribution Transformers
Common Faults and Causes in Routine Inspection of Distribution TransformersAs the terminal component of power transmission and distribution systems, distribution transformers play a critical role in supplying reliable electricity to end users. However, many users have limited knowledge of power equipment, and routine maintenance is often carried out without professional support. If any of the following conditions are observed during transformer operation, immediate action should be taken: Excess