Capacitas portans conductoris isolati

Descriptio

Hoc instrumentum calculat capacitem maximam continuam ducendi currentem per conductores insulatos, quorum tensio nominalis non superat 1 kV a.c. vel 1.5 kV d.c., iuxta tabulas B.52.2 ad B.52.13 IEC 60364-5-52. Certificat ne temperaturae conductoris excedat limitem thermicam insulationis in usu normali.

Parametri Input

  • Modus Installationis: Iuxta IEC 60364-5-52 (Tabula A.52.3), sicut in aere aperto, in canali, sepultus, et cetera. Nota: Non omnes modi agnoscuntur in regulis omnium nationum.

  • Materia Conductoris: Cuprum (Cu) vel Aluminium (Al), quae afficiunt resistivitatem et performance thermicam

  • Typus Insulationis:

    • Thermoplastica (PVC): Limites temperature conductoris 70°C

    • Thermosetting (XLPE aut EPR): Limites temperature conductoris 90°C

  • Dimensio Filii (mm²): Area sectionis transversalis conductoris

  • Temperatura Ambientalis: Temperatura medium circumstantis quando non onerata:

    • Factor correctionis temperaturae aeris: IEC 60364-5-52 Tabula B.52.14

    • Factor correctionis temperaturae terrae: IEC 60364-5-52 Tabula B.52.15

    • Correctio resistentiae thermicae soli: IEC 60364-5-52 Tabula B.52.16

  • Numero Conductorum Oneratorum: Numerus actualis conductorum ducendorum currentis:

    • Current directus: 2

    • Uniphasis: 2

    • Duplex sine neutro: 2

    • Duplex cum neutro: 3

    • Triplicis sine neutro: 3

    • Triplicis cum neutro (carga aequalis, sine harmonicis): 3

    • Triplicis cum neutro (carga inaequalis aut cum harmonicis): 4

  • Distortio Harmonica Totalis (DHT): Contentus currentis harmonicarum 3n totalis. Si ignotus, uti valore distortionis harmonicae totalis pro estimatione

  • Conductores Phasales in Parallelo: Conductores idem possunt coniungi in parallelo; maximum currentem permittibile est summa ratingorum individualium nuclei

  • Circuiti in Eodem Canale: Numerus circuitorum intra unum ductum alimentantium onera diversa (sicut 2 lineae pro 2 motoribus). Factores reductionis ex IEC 60364-5-52 Tabula B.52.17 applicentur.

  • Factor Derationis pro Cancellis Parallelis (si praesens): Applicatur quando plures series cancellorum installantur in singulo ductu. Quaeque series includit: unum conductor per phasem + unum neutrum (si opus sit) + unum conductor protectivus.

Resultata Output

  • Maxima current continua (A)

  • Valorem correctum pro temperatura ambientali

  • Factor reductionis pro circuitis multiplicibus

  • Factor derationis harmonicus

  • Standardes Referentiales: IEC 60364-5-52, Tabulae B.52.2–B.52.13

Designatum pro ingeniariis electricis et designatoribus ad selectandum cables insulatos convenientes pro systematis distributionis potestatis basso-tensionis, certificans operationem securam et conformem.

Donum da et auctorem hortare
Suggestus
Maximum Wire Length Calculator - Voltage Drop and Cable Length Tool
Calculatio longitatis maximae cabuli
Hoc instrumentum calculat longitudinem maximam cabli, quae adhiberi potest sine excessu permissi declivis tensionis et sine degradando insulamento, iuxta standardes IEC et NEC. Id supportat systemata DC, uniphasica, biphasica, et triphasica, includens conductores parallelos et varias gradationes temperaturarum. Parametri Input Typus Currentis: Directus Currentis (DC), Uniphasicus AC, Biphasicus, vel Triphasicus (3-filis/4-filis) Tensio (V): Inserito tensionem phase-to-neutral pro systemate uniphasico, vel phase-to-phase pro systemate polyphasico Potencia Onus (kW vel VA): Potentia nominata aequipmenti connecti Factor Potentiae (cos φ): Ratio potentiae activae ad apparentem, inter 0 et 1 (default: 0.8) Size Filii (mm²): Area sectionalis conductoris Conductores Phasales Paralleli: Conductores eadem size, longitudo, et materia possunt adhiberi in parallelum; summa permittendi currentis est summa ratingorum individualium core Declivis Tensionis (% vel V): Maximus declivis tensionis permittendus (exempli gratia, 3% pro luminibus, 5% pro motoribus) Materia Conductoris: Cuprum (Cu) vel Aluminium (Al), affectans resistivitatem Typus Cabli: Unipolaris: 1 conductor Bipolaris: 2 conductores Tripolaris: 3 conductores Quadrupolaris: 4 conductores Pentapolaris: 5 conductores Multipolaris: 2 vel plures conductores Temperatura Operationis (°C): Iuxta typum insulamenti: IEC/CEI: 70°C (PVC), 90°C (XLPE/EPR), 105°C (Insulamentum Mineralis) NEC: 60°C (TW, UF), 75°C (RHW, THHN, etc.), 90°C (TBS, XHHW, etc.) Resultata Output Maxima permittenda longitudo cabli (metra) Declivis tensionis actualis (% et V) Resistentia conductoris (Ω/km) Totalis resistentia circuiti (Ω) Standardes Referentiales: IEC 60364, NEC Article 215 Designatum pro ingenieris electricis et installatoribus ad planificandum layoutes cabling et assecurandum acceptabiles niveles tensionis ad termino onus.
Power Loss in Cables Calculator - I²R Loss and Electrical Energy Waste
Dissipatio potentiae per cables
Hoc instrumentum calculat perdas potentiae (perdas I²R) in cabulis propter resistentiam conductoris durante fluxu currentis, secundum normas IEC et NEC. Id supportat systemata DC, uniphasica, biphasica et triphasica, includens conductores parallelos et varios types insularum. Parametri Input Type Currentis: Directus Currentis (DC), Uniphasis AC, Biphasis, aut Triphasius (3-filis/4-filis) Voltage (V): Inseri voltage phase-to-neutral pro uniphasico, aut phase-to-phase pro polyphasico Potestas Onus (kW vel VA): Potestas nominata apparatus connecti Factor Potentiae (cos φ): Ratio potestatis activae ad apparentem, inter 0 et 1 (default: 0.8) Size Filo (mm²): Area sectionis transversalis conductoris Materia Conductoris: Cuprum (Cu) aut Aluminium (Al), quod afficit resistivitatem Conductores Phase Paralleli: Conductores eadem size, longitudo, et materia possunt uti in parallelum; summa currentis permittibilis est summa ratingorum core individualium Longitudo (metra): Distinctio unidirectionalis ab supply ad onus Temperatura Operativa (°C): Pro type insulari: IEC/CEI: 70°C (PVC), 90°C (XLPE/EPR), 105°C (Insulatio Mineralis) NEC: 60°C (TW, UF), 75°C (RHW, THHN, etc.), 90°C (TBS, XHHW, etc.) Resultata Output Resistentia Conductoris (Ω/km) Summa Resistentia Circuitus (Ω) Perda Potentiae (W vel kW) Perda Energetica (kWh/anno, optional) Cadens Voltage (% et V) Correctio Temperaturae pro Resistentia Normae Referentiales: IEC 60364, NEC Article 310 Designatum pro ingeniosis electricis et installatoribus ut evaluant efficaciam circuitus, consumptio energetica, et performance thermica.
Wire and Cable Sizing Calculator
Calculatio areae sectionis fili
Hoc instrumentum calculat aream sectionalem conductoris recommendatam basata in standardo IEC 60364-5-52, utens parametris sicut potencia onus, voltage, et longitudo circuiti. Parametri Input Tipo Currentis: DC, AC uniphasalis, biphasalis, vel triphasalis (tria filia vel quattuor filia) Voltage (V): Inter phasem et neutrum (uniphasalis) vel inter duas phases (multiphasalis) Potencia Onus (kW vel VA): Potentia nominata apparatus Factor Potentiae (cos φ): Intervallo 0–1, valor default 0.8 Longitudo Lineae (metri): Distantia unidirecta ab origine ad onus Maxima Voltage Decrescens Permissibilis (% vel V): Saepe 3% Temperatura Ambientalis (°C): Affectat capacitate portantis currentis conductoris Materia Conductoris: Cuprum (Cu) vel Alluminium (Al) Tipo Insulationis: PVC (70°C) vel XLPE/EPR (90°C) Modus Installationis: sicut superficiale, in ductu, sepultum (secundum Tabulam A.52.3 IEC) Numerus Circuitorum in Eodem Ductu: Utitur ad applicandum factor de-rating gruppi An omnes cables paralleli installati in uno ductu? Permitte tamanos conductorum minus quam 1.5 mm²? Resultati Output Aread sectionalis conductoris recommendata (mm²) Numerus parallelorum conductorum necessarius (si aliquid) Capacitas actualis portantis currentis (A) Decrescens calculata voltage (% et V) Conformitas cum requirementibus standardis IEC Tabulae standard referentiales (sicut B.52.2, B.52.17) Hoc instrumentum est designatum pro ingenieris electricis, installatoribus, et studentibus ut facili et conformiter dimensionent cables.
Inquiry
Descarica
Obtine Applicatio Commerciale IEE-Business
Utiliza app IEE-Business ad inveniendum apparatus obtinendumque solutiones coniungendum cum peritis et participandum in collaboratione industriale ubique et semper propter totam supportionem tuorum projectorum electricitatis et negotiorum